Menu
Search Icon

Need help choosing the right Product?

Get expert recommendations and a custom lighting plan within 1 day! Get Product Recommendations ➜

Detention Grade LED Exit Sign | Red Lettering | 16 Gauge Cold Roll Steel | 100-277V

SKU: LLS-DG-EXIT-SW-16G-R | Web ID: 2635
Starting at: $651.00
Built to Order 6 Weeks

Out of stock

Get your quote within 1 hour!

This fixture is a strong choice for commercial and industrial spaces where impact resistance and tamper resistance are priorities, thanks to its IK10 rating, 16-gauge cold rolled steel housing, and tamper-resistant T25 Torx fasteners. The powder coated finish and clear polycarbonate lens offer durability and corrosion resistance, while the integrated emergency backup battery ensures illumination during power loss - critical for egress and safety lighting. Surface and wall mounting options, along with compact dimensions, support installation in tight or institutional environments.

Dwayne Kula | President, CTO and Founder

Product Description

Proudly Made or Assembled in the USA - Supporting Domestic ManufacturingETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsVandal Resistant - Built to Withstand Impact and Tampering5 Year Unlimited Usage Warranty

Key Features

  • Voltage: 100V-277V
  • Optics: .125 Clear Polycarbonate
  • Mounting: Surface or Wall
  • Fixture Color: White

Durable Construction

  • Housing: 16-Gauge Cold Roll Steel | Powder Coated
  • Fasteners: T25 Torx with Center Pin Reject
  • IK Rating: IK10
  • Certifications: ETL | Rebate Eligible
  • Warranty: 5 years

Measurements

  • Dimensions (in): 16 3/16 in x 12 7/8 in x 2 13/16 in

Features/Accessories

  • Emergency Backup Battery

Web ID: 2635

Product Overview

This Detention Grade LED Exit Sign with red lettering is designed for use in correctional, detention, and secure facility environments where impact resistance and tamper resistance are required. The fixture features a 16-gauge cold roll steel housing with a powder-coated finish and clear polycarbonate optics for maximum durability. It operates on 100-277V input and includes an emergency backup battery for code-compliant egress marking during power loss.

Typical installations include secure corridors, holding cells, and psychiatric facilities where standard exit signs are not suitable due to risk of vandalism or tampering. The fixture is intended for surface or wall mounting and is sized for compatibility with institutional construction standards.

Core Performance and Output

This exit sign provides high-visibility red LED lettering behind .125-inch clear polycarbonate, ensuring clear egress marking in secure environments. The fixture is engineered for continuous operation on 100-277V circuits and includes an emergency backup battery to maintain illumination during outages. The optical assembly is designed for maximum legibility at standard corridor and room mounting heights.

IK10 impact rating supports use in high-abuse areas. Excessive output is not a concern for exit signage, but placement should avoid direct glare into occupied spaces. Uniformity and visibility are maintained within typical corridor lengths and sightlines.

Adjustability and Control Options

This fixture is designed for fixed surface or wall mounting. There are no field-adjustable optics or dimming controls. The emergency backup battery automatically engages during power loss, meeting code requirements for egress illumination.

No additional control options are provided. The fixture is intended for continuous operation and emergency egress support only.

Longevity and Reliability

The 16-gauge cold roll steel housing and clear polycarbonate lens provide long-term resistance to impact, tampering, and vandalism. Powder-coated finish resists corrosion in institutional environments. All fasteners are T25 Torx with center pin reject for tamper resistance.

LED source and emergency battery are rated for extended service life under continuous use. Routine inspection and periodic battery testing are recommended to maintain code compliance and operational readiness.

Build Quality and Physical Characteristics

The fixture measures 16 3/16 in x 12 7/8 in x 2 13/16 in and is finished in white. The housing is fabricated from 16-gauge cold roll steel and powder coated for durability. The clear polycarbonate lens is .125 in thick for maximum impact resistance.

All hardware is tamper-resistant. The fixture is designed for institutional environments where abuse and tampering are common concerns. The emergency battery is integrated within the housing for secure installation.

Where This Product Fits Best

This detention grade LED exit sign is intended for secure environments where standard exit signage is vulnerable to damage or tampering. It is suitable for correctional, detention, and psychiatric facilities, as well as secure corridors and holding cells. The fixture is also used in areas requiring vandal-resistant and tamper-resistant egress marking.

  • detention facility lighting
  • correctional facility lighting
  • secure area lighting
  • vandal resistant lighting
  • psychiatric facility lighting
  • holding cell lighting
  • secure corridor lighting
  • tamper resistant lighting

The fixture is designed for indoor use in institutional environments with high abuse risk. It is not intended for exterior or wet locations.

Installation and Long-Term Use

Surface or wall mounting is supported using tamper-resistant fasteners. The fixture is sized for compatibility with standard institutional construction and can be installed in corridors, cells, or secure rooms. All wiring is contained within the steel housing for security and code compliance.

Routine maintenance includes periodic battery testing and inspection of fasteners for tampering. The steel housing and polycarbonate lens minimize the need for frequent replacement in high-abuse areas. Emergency battery replacement is accessible by authorized personnel only.

How This Fixture Is Commonly Used

Typical mounting height is 7 to 9 feet above finished floor, aligned with corridor sightlines or above doorways. Spacing is determined by code requirements for egress visibility and facility layout, with fixtures placed at exits and along escape routes.

In high-abuse environments, fixture count may increase to ensure redundancy and visibility. Tradeoff: increased fixture density improves egress marking but may require additional maintenance checks for battery readiness.

Safety, Certifications, and Warranty

This fixture is ETL certified and meets IK10 impact resistance standards. It is eligible for rebate programs where applicable. The emergency backup battery supports code-compliant egress illumination during power loss.

All hardware is tamper-resistant. The fixture is covered by a 5-year warranty. Installation and maintenance should be performed by qualified personnel familiar with secure facility requirements.

Frequently Asked Questions

Q: What is the impact resistance rating of this exit sign?

A: The fixture is rated IK10 for maximum impact resistance in high-abuse environments.

Q: Does the exit sign include an emergency backup battery?

A: Yes, an emergency backup battery is integrated to provide illumination during power loss.

Q: What mounting options are available?

A: The fixture supports surface or wall mounting using tamper-resistant fasteners.

Q: Is this fixture suitable for exterior or wet locations?

A: No, this fixture is intended for indoor use in secure institutional environments only.

Q: How should spacing be determined for exit sign installation?

A: Spacing should follow code requirements for egress visibility and facility layout, typically at exits and along escape routes.

Application Questions and Clarification

Q: Can this exit sign be used in psychiatric or holding cell environments?

A: Yes, the fixture is designed for use in psychiatric facilities, holding cells, and other secure areas requiring tamper and vandal resistance.

Q: Is the lettering visible from standard corridor distances?

A: The red LED lettering is designed for clear visibility at typical corridor and room mounting heights.

Q: Are the fasteners tamper-resistant?

A: All fasteners are T25 Torx with center pin reject for tamper resistance.

Q: What is the recommended mounting height for this fixture?

A: Typical mounting height is 7 to 9 feet above finished floor, aligned with corridor sightlines or above doorways.