This adjustable LED shoebox fixture is a strong choice for outdoor area lighting thanks to its selectable wattage (170 – 240W) and color temperature (3000K, 4000K, 5000K), allowing precise adaptation to site needs. With up to 36,720 lumens at 153 lm/W, Type 3 distribution, and robust IP65-rated die-cast aluminum construction, it reliably handles parking lots, roadways, and perimeters exposed to rain and dust. Multiple mounting options simplify installation on poles or structures. It is UL listed, DLC Premium qualified, and rated for 100,000 hours.
Dwayne Kula | President, CTO and Founder
158 in stock



Product Specifications
Key Features
| Brand | LED Lighting Supply |
| Watts | 170 | 200 | 220 | 240 |
| Lumens | 26000 | 30600 | 33660 | 36720 |
| Lumens Per Watt | 153 |
| Replaces | 400 or 1000 Watt Metal Halide |
| Voltage | 100V-277V |
| Color Temperature | 3000K or 4000K or 5000K |
| CRI | 70+ |
| Dimming | No |
| Beam Angles (Std) | Type 3 |
| Optics | Polycarbonate Lens |
| Lifespan | 100,000 (L70) hours |
| Mounting (Opt) | Yoke or Arm or Slip Fitter |
| EPA Rating | 1.4 |
| Fixture Color | White |
| Frequency (Hz) | 50/60 |
| Power Factor | > .90 |
| THD | < 15% |
Durable Construction
| Housing | Die-Cast Aluminum |
| IP Rating | IP65 |
| Surge Protection | 10kV |
| Operating Temperature | -40°F to 113°F |
| Certifications | UL | DLC Premium |
| Warranty | 5 years |
Measurements
| Dimensions (in) | 16 L X 11.8 W X 3 H |
| Weight (lbs) | 9.1 |
Features/Accessories
- Color Adjustable
- Wattage Adjustable
- Optional Photocell
Download IES Files
Shoebox Fixture Lighting Layout Estimator
Use this estimator to calculate approximate fixture count, pole placement, spacing, and average foot-candles for parking lots, exterior areas, and outdoor sport court applications using the selected LED shoebox fixture. Enter the area size, mounting height, target foot-candles, light loss factor, and outdoor light use factor to generate a preliminary layout.
Project Inputs
Estimated Results
Estimated average foot-candles are preliminary. The visual heat map is normalized to the estimated average and is intended to show approximate coverage behavior, not a verified lighting plan.
Parking Lot / Exterior Area Mode: Fixtures are placed on poles along the longest edges of the area. Edge fixtures are modeled as level / down-facing shoebox fixtures with the optic directed inward. For wider parking areas, a center row can be added.
Sport Court Mode: Poles are placed on the long edges of the court. Fixtures are modeled as level / down-facing and directed toward court coverage zones instead of being tilted toward one center point.
Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data to improve the visual ground-level light distribution. When IES photometry is not available, the estimator uses a simulated Type 3 or Type 5 optic model based on lumens, mounting height, outdoor light use factor, light loss factor, and fixture direction.
Outdoor Light Use Factor: Suggested starting points: open rectangular paved area 0.60–0.70, typical parking lot 0.45–0.60, areas with setbacks or edge losses 0.35–0.50, complex outdoor sites 0.25–0.40.
Preliminary Estimate Only: This estimator is intended for simple rectangular outdoor areas. Actual light levels may vary based on fixture optics, pole setbacks, mounting height, fixture orientation, distribution type, surface reflectance, obstructions, voltage, installation conditions, spill light requirements, and site-specific requirements.
This estimate is a starting point. Parking lots, roadways, sport courts, public areas, campuses, vehicle areas, and code-sensitive exterior projects should be reviewed with a lighting plan before purchase or installation.
Product Overview
This adjustable LED shoebox light provides 26,000 to 36,720 lumens with selectable 170W, 200W, 220W, and 240W output settings. It uses a Type 3 distribution for forward-throw exterior lighting layouts.
The fixture is configured for parking lot lighting, commercial site lighting, area lighting, and roadway perimeter lighting. It can replace 400W or 1000W metal halide fixtures where the existing pole, mounting position, and layout support the selected output.
Core Performance and Output
Output ranges from 26,000 lumens at 170W to 36,720 lumens at 240W. Fixture efficacy is 153 lumens per watt, with 100-277V input, 50/60Hz operation, power factor above 0.90, and THD below 15%.
The standard Type 3 optic directs light forward from the pole or mounting point. Higher wattage settings can reduce fixture count in a layout, but may produce excessive light at low mounting heights or near property edges.
Adjustability and Control Options
Field-adjustable wattage settings are 170W, 200W, 220W, and 240W. Color temperature is selectable between 3000K, 4000K, and 5000K.
This fixture does not include dimming. An optional photocell is available for dusk-to-dawn operation where photocell control is required.
Longevity and Reliability
The LED system is rated for 100,000 hours L70. The fixture includes 10kV surge protection for exterior electrical environments.
Operating temperature is rated from -40F to 113F. Long-term performance depends on maintaining secure mounting, intact wiring connections, and proper protection of the supply circuit.
Build Quality and Physical Characteristics
The housing is die-cast aluminum with a white finish. A polycarbonate lens protects the Type 3 optical system.
The fixture measures 16 inches long by 11.8 inches wide by 3 inches high and weighs 9.1 pounds. It is IP65 rated and supports yoke, arm, or slip fitter mounting options.
Where This Product Fits Best
This shoebox light fits pole-mounted and structure-mounted exterior layouts requiring a forward-throw Type 3 distribution. Its adjustable output supports locations with different light-level and mounting-layout requirements.
- parking lot lighting
- commercial site lighting
- area lighting
- roadway perimeter lighting
- campus lighting
- dealership lighting
- apartment complex lighting
- industrial yard lighting
The IP65 rating, die-cast aluminum housing, polycarbonate lens, and -40F to 113F operating range support exposed outdoor conditions. EPA rating is 1.4.
Installation and Long-Term Use
Installation requires selection of the yoke, arm, or slip fitter mounting method before mounting work begins. The mounting structure and fixture position must support the fixture weight and EPA rating.
Set wattage and color temperature during installation, then verify aiming and forward light distribution before final commissioning. The optional photocell should be selected only when photocell control is part of the site lighting design.
How This Fixture Is Commonly Used
For parking lot lighting, commercial site lighting, area lighting, and roadway perimeter lighting, fixtures are typically placed along poles or exterior mounting points with the Type 3 optic aimed into the intended coverage area. Mounting height affects forward throw, uniformity, glare, and light levels at the perimeter.
Campus lighting, dealership lighting, apartment complex lighting, and industrial yard lighting require a layout that accounts for pole locations, fixture orientation, and selected wattage. Higher output can extend coverage from each fixture, but the final spacing pattern depends on mounting height and required light levels.
Safety, Certifications, and Warranty
UL listed. DLC Premium listed.
This fixture includes a 5-year warranty.
Frequently Asked Questions
Q: What wattage settings are available?
A: Wattage is adjustable to 170W, 200W, 220W, or 240W.
Q: What color temperatures are available?
A: Color temperature is adjustable to 3000K, 4000K, or 5000K.
Q: Does this shoebox light support dimming?
A: No. This fixture does not include dimming.
Q: Which mounting options are available?
A: Available mounting options are yoke, arm, and slip fitter.
Application Questions and Clarification
Q: Is this fixture suited for parking lot lighting and commercial site lighting?
A: Yes. Parking lot lighting and commercial site lighting are primary applications for this shoebox light.
Q: What should be considered when planning fixture placement?
A: Mounting height, selected wattage, Type 3 distribution, fixture orientation, target light levels, and layout requirements affect placement. A specific spacing value is not established by the supplied product data.
Q: Can this fixture be used for campus lighting or apartment complex lighting?
A: Yes. Campus lighting and apartment complex lighting are supported secondary applications. Final fit depends on the selected wattage, mounting method, and site layout.