Product Specifications
UL Specs
- UL 844 Hazardous Locations
- Class 1, Division 2, Groups A,B,C,D
- Class 2, Division 1, Groups E,F,G
- Class 2, Division 2, Groups F,G
- Class 3
- Zones
- 1/2, 21/22
Wet Locations (UL 1598), Outside Type (Salt Water), T4A Temperature Rating, UL1598A
Key Features
| Brand | LED Lighting Supply |
| Watts | 100 |
| Lumens | 13000 |
| Lumens Per Watt | 130 |
| Replaces | 250 Watt Metal Halide |
| Voltage | 100V-277V |
| Color Temperature | 5000K |
| CRI | 70+ |
| Dimming | No |
| Beam Angles (Std) | 120° |
| Optics | Tempered Glass Lens |
| Lifespan | 50,000 (L70) hours |
| Mounting | Yoke or 3/4 in NPT Pendant |
| Frequency (Hz) | 50-60Hz |
| Power Factor | >.98 |
| THD | < 10% |
Durable Construction
| Housing | Copper Free Aluminum |
| Housing | Copper Free Aluminum |
| IP Rating | IP68 |
| IK Rating | IK09 |
| Surge Protection | 10kV |
| Operating Temperature | -22°F to 122°F |
| Certifications | UL | Rebate Eligible |
| Warranty | 5 years |
Measurements
| Dimensions (in) | 12 x 12 x 6.6 |
| Weight (lbs) | 17 |
Download IES Files
Product Lighting Layout Estimator
Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.
Project Inputs
Estimated Results
Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.
Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.
Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.
Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.
This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.
Product Overview
This 100-watt square explosion proof LED light delivers 13,000 lumens at 5000K for hazardous location lighting. It operates on 100-277V and uses a 120-degree beam distribution with a tempered glass lens.
The fixture is rated for Class I, Division 2; Class II, Divisions 1 and 2; Class III; and Zones 1/2 and 21/22 locations. It is commonly used as a 250-watt metal halide replacement where hazardous-location ratings and sealed construction are required.
Core Performance and Output
The fixture produces 13,000 lumens at 130 lumens per watt. The 120-degree beam angle provides broad light distribution from a single square fixture.
It operates on 100-277V, 50-60Hz power, with a power factor above 0.98 and total harmonic distortion below 10 percent. The 13,000-lumen output can be excessive where low mounting heights or concentrated task areas require lower light levels.
Adjustability and Control Options
This fixture is not dimmable. Output remains fixed at 100 watts and 13,000 lumens.
Mounting is available through a yoke or 3/4-inch NPT pendant connection. The selected mounting method should match the available structure and fixture orientation requirements.
Longevity and Reliability
The LED system is rated for 50,000 hours at L70. This rating identifies the point at which light output is expected to reach 70 percent of initial output.
Integrated 10kV surge protection supports installation on commercial and industrial electrical systems. The operating temperature range is -22 degrees F to 122 degrees F.
Build Quality and Physical Characteristics
The housing is copper-free aluminum with a tempered glass lens. The fixture measures 12 by 12 by 6.6 inches and weighs 17 pounds.
IP68 and IK09 ratings support use in wet and impact-prone hazardous environments. The fixture is rated for outside type salt water locations.
Where This Product Fits Best
This fixture fits hazardous locations requiring a Class I, II, or III rated LED light with broad distribution, sealed construction, and 100-277V operation.
- hazardous location lighting
- paint booth lighting
- chemical processing facility lighting
- explosion proof lighting
- oil and gas facility lighting
- refinery lighting
Its IP68 rating, outside type salt water rating, and copper-free aluminum housing support demanding exposure conditions. Final placement must align with the applicable area classification and mounting arrangement.
Installation and Long-Term Use
The fixture can be installed with the yoke mount or through a 3/4-inch NPT pendant connection. Support structure, mounting orientation, and wiring access should be confirmed before installation.
For long-term service, maintain access to the fixture and inspect the lens, mounting hardware, and electrical connections during scheduled maintenance. The 17-pound fixture weight should be included in mounting support review.
How This Fixture Is Commonly Used
In hazardous location lighting, paint booth lighting, and chemical processing facility lighting, fixtures are positioned according to mounting height, required light levels, and the classified area layout. The broad 120-degree distribution is typically used where wide-area illumination is needed.
Oil and gas facility lighting and refinery lighting layouts require fixture placement around equipment, structural obstructions, and access paths within the approved classified area. Higher output can reduce fixture count, but layout decisions must also account for uniformity and glare.
Safety, Certifications, and Warranty
UL 844 Hazardous Locations. UL 1598 Wet Locations. UL 1598A. Class I, Division 2, Groups A, B, C, and D. Class II, Division 1, Groups E, F, and G. Class II, Division 2, Groups F and G. Class III. Zones 1/2 and 21/22.
The fixture has a T4A temperature rating, IP68 rating, IK09 rating, and a five-year warranty. It is rebate eligible.
Frequently Asked Questions
Q: What is the light output of this explosion proof fixture?
A: The fixture produces 13,000 lumens at 100 watts with an efficacy of 130 lumens per watt.
Q: What voltage does this fixture operate on?
A: It operates on 100-277V, 50-60Hz power.
Q: Can this fixture be dimmed?
A: No. This fixture is not dimmable.
Q: Which mounting options are available?
A: The fixture is available with a yoke mount or a 3/4-inch NPT pendant mount.
Application Questions and Clarification
Q: Is this fixture rated for paint booth lighting?
A: Yes. Paint booth lighting is a primary application for this explosion proof fixture.
Q: Can this fixture be used for oil and gas facility lighting?
A: Oil and gas facility lighting is a listed secondary application. The applicable area classification must match the fixture ratings.
Q: What should be considered when planning fixture placement?
A: Mounting height, target light levels, structural obstructions, and classified area layout affect fixture placement. A specific spacing value is not established by the supplied product data.
Web ID: 1804