200 Watt Square Explosion Proof LED Light | 26000 Lumens | Class 1 Div 2 | 5000K | 100-277V
64 in stock
Product Specifications
UL Specs
- UL 844 Hazardous Locations
- Class 1, Division 2, Groups A,B,C,D
- Class 2, Division 1, Groups E,F,G
- Class 2, Division 2, Groups F,G
- Class 3
- Zones
- 1/2, 21/22
Wet Locations (UL 1598), Outside Type (Salt Water), T4A Temperature Rating, UL1598A
Key Features
| Brand | LED Lighting Supply |
| Watts | 200 |
| Lumens | 26000 |
| Lumens Per Watt | 130 |
| Replaces | 400 Watt Metal Halide |
| Voltage | 100V-277V |
| Color Temperature | 5000K |
| CRI | 70+ |
| Dimming | No |
| Beam Angles (Std) | 120° |
| Optics | Tempered Glass Lens |
| Lifespan | 50,000 (L70) hours |
| Mounting | Yoke or 3/4 in NPT Pendant |
| Frequency (Hz) | 50-60Hz |
| Power Factor | >.98 |
| THD | < 10% |
Durable Construction
| Housing | Copper Free Aluminum |
| IP Rating | IP68 |
| IK Rating | IK09 |
| Surge Protection | 10kV |
| Operating Temperature | -40°F to 122°F |
| Certifications | UL | Rebate Eligible |
| Warranty | 5 years |
Measurements
| Dimensions (in) | 15.8 x 15.8 x 6.6 |
| Weight (lbs) | 24 |
Download IES Files
Product Lighting Layout Estimator
Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.
Project Inputs
Estimated Results
Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.
Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.
Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.
Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.
This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.
Product Overview
This 200 watt square explosion proof LED light delivers 26,000 lumens at 5000K for classified hazardous locations. It operates on 100-277V and uses a 120 degree beam distribution.
The fixture is configured for hazardous location lighting, explosion proof lighting, paint booth lighting, and chemical processing facility lighting. It replaces a 400 watt metal halide fixture where the existing application and classification match the listed ratings.
Core Performance and Output
This fixture produces 26,000 lumens at 130 lumens per watt. The 5000K color temperature and 70+ CRI support general visibility in classified work areas.
The standard 120 degree beam angle provides broad distribution from yoke or pendant mounting positions. Output can be excessive at lower mounting heights, while higher mounting heights require layout review to maintain uniformity.
Adjustability and Control Options
This fixture is not dimmable. It operates on 100-277V, 50-60Hz power.
Power factor is greater than 0.98 and total harmonic distortion is less than 10 percent. The fixture includes 10kV surge protection.
Longevity and Reliability
Rated life is 50,000 L70 hours. The operating temperature range is -40F to 122F.
The IP68 rating supports wet location conditions. The IK09 rating provides impact resistance for demanding industrial installations.
Build Quality and Physical Characteristics
The housing is copper free aluminum with a tempered glass lens. The fixture measures 15.8 x 15.8 x 6.6 inches and weighs 24 pounds.
Mounting options are a yoke mount or 3/4 inch NPT pendant mount. The selected mounting method must match the supporting structure and classified-location installation requirements.
Where This Product Fits Best
This fixture fits classified indoor and outdoor work areas where the listed hazardous-location classifications, wet-location rating, and environmental ratings apply.
- hazardous location lighting
- paint booth lighting
- chemical processing facility lighting
- oil and gas facility lighting
- refinery lighting
- solvent storage area lighting
UL 844 hazardous location listing includes Class I, Division 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; Class III; and Zones 1/2 and 21/22. It is rated IP68, IK09, Wet Locations UL 1598, Outside Type Salt Water, and T4A.
Installation and Long-Term Use
The yoke mount allows directional fixture positioning, while the 3/4 inch NPT pendant mount supports suspended installation. Fixture weight, mounting structure, and classified-location wiring methods must be addressed before installation.
Long-term service planning should account for the 24 pound fixture weight and access to the mounting location. The tempered glass lens and copper free aluminum housing support use across the stated operating temperature range.
How This Fixture Is Commonly Used
In hazardous location lighting and chemical processing facility lighting, fixtures are positioned according to mounting height, target light levels, and the work-area layout. Paint booth lighting layouts require the fixture classification and mounting arrangement to match the project conditions.
The 120 degree beam supports broader distribution patterns from overhead mounting locations. Spacing varies with mounting height, required light levels, and the number of fixtures in the layout.
Safety, Certifications, and Warranty
UL 844 hazardous locations. UL 1598 wet locations. UL 1598A. Class I, Division 2, Groups A, B, C, D. Class II, Division 1, Groups E, F, G. Class II, Division 2, Groups F, G. Class III. Zones 1/2 and 21/22.
This fixture carries a 5 year warranty. It is rebate eligible.
Frequently Asked Questions
Q: What is the light output of this explosion proof fixture?
A: The fixture delivers 26,000 lumens while consuming 200 watts. Efficacy is 130 lumens per watt.
Q: What voltage does this fixture operate on?
A: The fixture operates on 100-277V, 50-60Hz power.
Q: Is this fixture dimmable?
A: No. This fixture is not dimmable.
Q: What mounting options are available?
A: The fixture is available with yoke mounting or 3/4 inch NPT pendant mounting.
Q: What should be considered when planning fixture layout?
A: Mounting height, target light levels, fixture output, and the 120 degree beam angle affect layout. The supplied product data does not establish a specific spacing value or fixture quantity.
Application Questions and Clarification
Q: Can this fixture be used for paint booth lighting?
A: Paint booth lighting is a listed application. The project classification must match the fixture’s listed hazardous-location ratings.
Q: Can this fixture be used for oil and gas facility lighting?
A: Oil and gas facility lighting is a listed application. Verify the area classification against the fixture’s Class I, Division 2, Groups A, B, C, and D listing and other listed classifications.
Q: What environmental conditions are supported by the fixture ratings?
A: The fixture is rated IP68, IK09, Wet Locations UL 1598, Outside Type Salt Water, and -40F to 122F operation.