Menu
Search Icon

5 Watt Emergency Light and Exit Sign | 90 Minute Battery Backup | Black | Red Lettering

SKU: MLLG-LN-LED-EXIT2-2L-B | Web ID: 2581
Starting at: $42.78
Availability: 185 In Stock Ships 3-5 Days

185 in stock

Product total

Options total

Sub-Total

Get your quote within 1 hour!

This 5 watt emergency light and exit sign combination is a practical choice for commercial and industrial spaces needing both exit identification and emergency egress lighting from a single surface-mounted fixture. Its 100V-277V universal voltage input simplifies installation across varied electrical systems, while the 90-minute battery backup meets standard emergency requirements. The thermoplastic ABS housing resists UV discoloration, making it suitable for areas with ambient or natural light. Adjustable LED heads provide broad 120-degree coverage, and the 50,000-hour lifespan reduces maintenance. This fixture is ideal for exit doorways, stairwell entries, and corridor intersections.

Dwayne Kula | President, CTO and Founder

Product Description

UL Listed - Verified for Electrical Safety and Performance3 Year Unlimited Usage Warranty

Key Features

  • Watts: 5
  • Replaces: 36W CFL
  • Voltage: 100V-277V
  • Dimming: No
  • Beam Angles (Alt): 120°
  • Lifespan: 50,000 hours
  • Mounting: Surface
  • Fixture Color: Black
  • Frequency (Hz): 50/60
  • Power Factor: > .90
  • THD: < 20%

Durable Construction

  • Housing: Injection-Molded Thermoplastic ABS
  • Certifications: UL
  • Warranty: 3 years

Measurements

  • Dimensions (in): 12 X 7.5 X 4.4

This Emergency Exit LED Light is the most economical LED Combo (including LED emergency light heads) for general purpose applications.

The injection molded, thermoplastic material resists discoloration due to UV radiation, and the energy-efficient, low-maintenance LEDs provide bright illumination. The unit has universal mounting capability.


Request IES Files

Web ID: 2581

Product Overview

This 5 Watt Emergency Light and Exit Sign is designed for code-compliant egress marking and emergency illumination in commercial and industrial buildings. The fixture integrates a red-lettered exit sign with dual emergency light heads, providing clear visibility during power loss. Typical installations include corridors, stairwells, and exit pathways in offices, warehouses, and public buildings where reliable exit identification is required.

The unit operates on 100-277V and includes a 90-minute battery backup for uninterrupted operation during outages. The black, injection-molded thermoplastic ABS housing resists discoloration and impact, supporting long-term use in high-traffic environments.

Core Performance and Output

This fixture delivers 5 watts of LED output, replacing traditional 36W CFL exit sign and emergency light combinations. The 120° beam angle provides wide-area illumination for egress paths, while the 5000K color temperature ensures high visibility in emergency conditions. Power factor exceeds 0.90, and total harmonic distortion remains below 20% for stable electrical performance.

Output is suitable for standard ceiling heights and corridor widths. Excessive mounting heights or unusually wide spaces may require supplemental emergency lighting to maintain code-required illumination levels.

Adjustability and Control Options

The emergency light heads are fixed in position for broad coverage of exit routes. No dimming or advanced control options are included. The fixture operates automatically during power loss, switching to battery backup without user intervention.

Manual test functions are accessible for routine inspection and code compliance checks. There are no integrated remote control or networked monitoring features.

Longevity and Reliability

LED components are rated for 50,000 hours of operation, minimizing maintenance cycles compared to legacy lamp types. The battery backup system provides a minimum of 90 minutes of emergency operation per code requirements.

Thermoplastic ABS construction resists UV discoloration and impact, supporting reliable performance in commercial corridors and stairwells. Routine battery testing and periodic replacement are recommended to maintain emergency readiness.

Build Quality and Physical Characteristics

The fixture measures 12 x 7.5 x 4.4 inches and is constructed from injection-molded thermoplastic ABS. The housing is designed for surface mounting and includes universal mounting capability for wall or ceiling installation.

Black finish with red lettering provides high contrast for exit identification. The unit is UL certified and includes a 3-year warranty. All components are designed for indoor use in conditioned spaces.

Where This Product Fits Best

This emergency exit sign and light combination is intended for indoor environments requiring code-compliant egress marking and emergency illumination. It is commonly installed in:

  • egress lighting
  • emergency exit lighting
  • code compliance lighting
  • life safety lighting
  • commercial building exit marking
  • industrial facility exit lighting
  • warehouse exit lighting
  • public building exit lighting

Suitable for use in offices, warehouses, industrial facilities, and public buildings. Not intended for outdoor or wet locations. Performance is optimized for standard ceiling heights and typical corridor or stairwell dimensions.

Installation and Long-Term Use

Surface mounting is supported for both wall and ceiling applications. Universal mounting hardware is included for flexibility during installation. Electrical connections accommodate 100-277V input, compatible with most commercial building circuits.

Routine inspection and battery testing are required to maintain code compliance. Battery replacement intervals depend on usage and local regulations. The fixture is designed for straightforward maintenance access.

How This Fixture Is Commonly Used

Commonly installed above doors, in corridors, and at stairwell landings to mark exit routes and provide emergency illumination. Typical mounting heights range from 7 to 10 feet, depending on ceiling height and line-of-sight requirements.

Spacing is determined by local code and the need for continuous egress illumination. Higher output fixtures may reduce the number of units required, but excessive spacing can create dark spots along exit paths.

Safety, Certifications, and Warranty

This fixture is UL certified for emergency egress and exit sign applications. The housing is constructed from flame-retardant thermoplastic ABS for added safety in occupied spaces.

The product includes a 3-year warranty covering manufacturing defects. All components are designed to meet life safety and code compliance requirements for commercial and industrial buildings.

Frequently Asked Questions

Q: What is the battery backup duration for this emergency exit sign?

A: The battery backup provides a minimum of 90 minutes of emergency operation during power loss.

Q: Can this fixture be mounted on both walls and ceilings?

A: Yes, the fixture supports universal surface mounting for both wall and ceiling installations.

Q: Is this exit sign suitable for outdoor or wet locations?

A: No, this fixture is intended for indoor use only and is not rated for wet or outdoor environments.

Q: What is the recommended mounting height for optimal visibility?

A: Typical mounting heights range from 7 to 10 feet, depending on ceiling height and line-of-sight requirements.

Q: How often should the battery be tested or replaced?

A: Battery testing should be performed according to local code, typically monthly, with replacement as needed based on performance and inspection results.

Application Questions and Clarification

Q: Is this fixture compliant for use as emergency egress lighting in commercial buildings?

A: Yes, this fixture is UL certified and designed for code-compliant emergency egress and exit sign applications in commercial buildings.

Q: Can this exit sign be used in industrial facilities and warehouses?

A: Yes, it is suitable for industrial facility exit lighting and warehouse exit lighting where indoor code-compliant egress marking is required.

Q: Does the fixture provide both exit signage and emergency illumination?

A: Yes, the unit combines a red-lettered exit sign with integrated emergency light heads for dual function in a single fixture.

Q: What are the main limitations for installation environments?

A: The fixture is not rated for outdoor, wet, or hazardous locations and should only be installed in indoor, conditioned spaces.