Need help choosing the right Product?
Get expert recommendations and a custom lighting plan within 1 day! Get Product Recommendations ➜
You may also like...
-
5 Watt LED Exit Sign | 90 Minute Battery Backup | Red or Green Letters
Red:Out of StockGreen:645 In StockShips 3-5 DaysRetail Price: $32.00 -
2 Watt LED Exit Sign | 90 Minute Battery Backup | Wet Location Rated
Availability: 989 In Stock Ships 2-3 DaysRetail Price: $71.11 -
2 Watt LED Emergency Light | 90 Minute Battery Backup
Availability: 2075 In Stock Ships 3-5 DaysRetail Price: $29.62
4 Watt LED Exit Sign | 120 Minute Battery Backup | New York City Approved
156 in stock
This 4 watt LED exit sign is a strong choice for commercial and industrial buildings requiring New York City code compliance, thanks to its 120-minute battery backup, UL listing, and NYC approval. Its wet location and fire-resistant ratings make it suitable for environments like parking garages, loading docks, mechanical rooms, stairwells, and covered exterior walkways where moisture or fire exposure is a concern. The 100V-277V input range and surface or wall mount options simplify installation across standard commercial circuits.
Product Description
Key Features
- Watts: 4
- Voltage: 100V-277V
- Dimming: No
- Lifespan: 50,000 hours
- Mounting: Surface or Wall
- Fixture Color: White
- Frequency (Hz): 50/60
- Power Factor: > .90
- THD: < 20%
Durable Construction
- Housing: Aluminum
- IP Rating: Wet Location Rated
- Certifications: UL
- Warranty: 2 years
Measurements
- Dimensions (in): 14 X 10.5 X 2
- Weight (lbs): 3.5 lbs
LED Emergency Exit Sign with 120 Min Emergency Backup. New York City Approved. Damp Location Rated, fire-resistant.
Web ID: 2321
Product Overview
This 4 Watt LED Exit Sign is designed for emergency egress and exit marking in commercial and industrial environments. It provides clear, illuminated exit signage with a 120-minute battery backup for code-compliant life safety coverage. The fixture is approved for use in New York City and is suitable for wet locations, making it appropriate for both interior and select exterior egress paths.
The housing is fire-resistant aluminum, and the unit operates on 100-277V input. Typical installations include stairwells, corridors, and building exits where reliable emergency exit visibility is required. Surface or wall mounting options support a range of building layouts and retrofit scenarios.
Core Performance and Output
This exit sign delivers 4 watts of LED illumination at 5000K, providing high-contrast visibility for exit pathways. The fixture maintains consistent output during normal operation and automatically switches to battery backup for up to 120 minutes during power loss. Power factor exceeds 0.90, and total harmonic distortion is below 20%.
Uniform face illumination ensures legibility from standard viewing distances. Output is optimized for code-compliant egress marking, not for general area lighting. Excessive ambient light or mounting above recommended heights may reduce sign visibility.
Adjustability and Control Options
This fixture does not include dimming or advanced control features. Operation is automatic, with integrated battery backup and self-contained switching between normal and emergency modes. The sign is designed for continuous illumination and emergency activation without user intervention.
Directional arrows and faceplate configuration are set during installation. No remote control or network integration is provided.
Longevity and Reliability
Rated for 50,000 hours of LED life, this exit sign is built for long-term reliability in demanding environments. The battery backup system is engineered for repeated charge/discharge cycles and provides a minimum of 120 minutes of emergency operation per code requirements.
Routine inspection and periodic battery testing are recommended to maintain code compliance and operational readiness. The fixture is covered by a 2-year warranty.
Build Quality and Physical Characteristics
The housing is constructed from fire-resistant aluminum and finished in white. The fixture measures 14 x 10.5 x 2 inches and weighs 3.5 lbs, supporting secure mounting on standard wall or surface locations. The design is suitable for wet locations and meets UL listing requirements.
All components are sealed to prevent moisture ingress. The unit is designed for durability in high-traffic and public areas, with a robust enclosure to withstand routine impacts and cleaning.
Where This Product Fits Best
This LED exit sign is intended for use in commercial, industrial, and public buildings where code-compliant emergency egress marking is required. It is suitable for both new construction and retrofit projects in environments with high occupancy or regulated safety standards.
- egress lighting
- emergency exit lighting
- code compliance lighting
- life safety lighting
- commercial building exit marking
- industrial facility exit lighting
- warehouse exit lighting
- public building exit lighting
Wet location rating and fire-resistant construction allow deployment in stairwells, corridors, and exit paths exposed to moisture or humidity. The fixture is approved for use in New York City and other jurisdictions with strict code requirements.
Installation and Long-Term Use
Surface or wall mounting is supported using standard hardware. The fixture?s compact size and light weight simplify installation in tight or overhead locations. Electrical connection is made to 100-277V supply, with battery backup integrated inside the housing.
Routine maintenance includes periodic battery testing and visual inspection for damage or obstruction. The fixture is designed for minimal service requirements, with no lamp replacement needed during its rated life. Battery replacement may be required over time depending on usage and test results.
How This Fixture Is Commonly Used
Typical mounting heights range from 7 to 10 feet above finished floor, positioned above doors, at corridor intersections, or along egress routes. Spacing is determined by code requirements and sightline considerations, with additional units installed at changes in direction or where visibility may be obstructed.
In high-occupancy or multi-story buildings, exit signs are deployed at every required exit and along all designated egress paths. Higher ambient light levels may require closer spacing or additional signs to maintain visibility. Battery backup ensures continued operation during power outages, supporting safe evacuation.
Safety, Certifications, and Warranty
This fixture is UL listed, wet location rated, and approved for use in New York City. The housing is fire-resistant and suitable for installation in code-regulated environments. All components are designed to meet life safety and emergency egress requirements.
The product includes a 2-year warranty covering defects in materials and workmanship. Compliance with local codes and periodic testing are required for continued code acceptance.
Frequently Asked Questions
Q: What is the emergency backup duration for this exit sign?
A: The fixture provides 120 minutes of battery backup during power loss.
Q: Is this exit sign approved for use in New York City?
A: Yes, this model is New York City approved.
Q: Can this exit sign be installed in wet or damp locations?
A: The fixture is wet location rated and suitable for installation in areas exposed to moisture.
Q: What mounting options are available?
A: Surface and wall mounting are supported using standard hardware.
Q: Does the fixture support dimming or remote control?
A: No, this exit sign does not include dimming or remote control features.
Q: How often should the battery be tested or replaced?
A: Battery testing should be performed according to local code requirements. Replacement is based on test results and battery condition.
Q: How should spacing be determined for exit sign installation?
A: Spacing is based on code requirements, sightlines, and ambient lighting. Additional signs may be needed at direction changes or where visibility is limited.
Application Questions and Clarification
Q: Is this exit sign suitable for warehouse exit lighting?
A: Yes, this fixture is commonly used for warehouse exit lighting and meets code requirements for egress marking.
Q: Can this sign be used in public building exit lighting applications?
A: The fixture is suitable for public building exit lighting, including schools, offices, and other high-occupancy spaces.
Q: Does this product meet code compliance lighting requirements?
A: Yes, it is designed for code compliance lighting and is UL listed and New York City approved.
Q: Is this fixture appropriate for industrial facility exit lighting?
A: The sign is suitable for industrial facility exit lighting, including areas with wet or humid conditions.





