4 Watt LED Emergency Light | 90 Minute Battery Backup

SKU: MLLG-WD-LED-EML-2 Web ID: 2053
Starting at: $36.00

Availability: 1479 In Stock Ships 3-5 Days

This 4 watt LED emergency light is a practical choice for interior commercial and industrial spaces needing reliable backup illumination during power outages. Its two independently adjustable heads allow targeted coverage of egress paths, stairwells, or storage areas, while the 300-lumen output and 90-minute battery runtime meet standard emergency lighting requirements. The universal 100V-277V input simplifies installation across various building systems, and the durable thermoplastic ABS housing withstands typical indoor wear. Wall mounting is straightforward, and ETL listing ensures code compliance. This fixture is not intended for wet locations or outdoor use.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

1479 in stock

Product total

Options total

Sub-Total

Product Specifications

ETL Listed - Certified for Product Safety Compliance to North American Standards3 Year Unlimited Usage Warranty

Key Features

Brand LED Lighting Supply
Watts 4
Lumens 300
Lumens Per Watt 75
Voltage 100V-277V
Dimming No
Beam Angles (Std) 120°
Lifespan 50,000 hours
Mounting Wall
Fixture Color White
Frequency (Hz) 50/60
Power Factor .97
THD < 20%

Durable Construction

Housing Injection-Molded Thermoplastic ABS
Certifications ETL
Warranty 3 years

Measurements

Dimensions (in) 11 X 4.5 X 2.5
Weight (lbs) 19.6 lbs

4 Watt Emergency Exit LED Light produces 300 lumens for up to 90 minutes. LED heads are adjustable, so you can aim and point for optimal light distribution.

Product Overview

This 4 watt LED emergency light provides 300 lumens of 5000K illumination during a power interruption. It includes a 90 minute battery backup and two adjustable LED heads for directing emergency light where it is needed.

The wall-mounted unit is intended for egress lighting and emergency exit lighting in commercial and industrial buildings. Its white injection-molded thermoplastic ABS housing is compact enough for wall locations near exit paths.

Core Performance and Output

The fixture operates at 4 watts and produces 300 lumens at 75 lumens per watt. The standard 120 degree beam distribution provides broad emergency illumination from each adjustable head.

Input voltage is 100-277V at 50/60Hz. Power factor is 0.97, and total harmonic distortion is below 20 percent.

The 300 lumen output is intended for localized emergency lighting coverage. Head direction and wall location affect the light distribution across the egress path.

Adjustability and Control Options

Each LED head is adjustable for aiming light toward the required emergency area. The heads can be positioned independently to address the wall-mounted fixture location and surrounding path.

This emergency light is not dimmable. It operates from 100-277V input power and transfers to battery backup operation during an outage.

Longevity and Reliability

The LED light source is rated for 50,000 hours of life. The battery backup provides illumination for up to 90 minutes.

Long-term reliability depends on maintaining the fixture, battery backup function, wall mounting condition, and electrical connection. Emergency operation should be verified as part of the facility’s regular life safety lighting checks.

Build Quality and Physical Characteristics

The housing is injection-molded thermoplastic ABS with a white finish. The fixture measures 11 x 4.5 x 2.5 inches.

Fixture weight is listed as 19.6 pounds. Wall mounting keeps the unit accessible for inspection, battery testing, and LED head adjustment.

Where This Product Fits Best

This emergency light fits interior commercial and industrial exit-path locations requiring backup illumination during a power interruption. Its wall-mounted configuration supports emergency lighting positions where adjustable heads can be aimed along the required route.

  • emergency exit lighting
  • egress lighting
  • life safety lighting
  • code compliance lighting
  • commercial building exit marking
  • industrial facility exit lighting

The thermoplastic ABS housing is intended for indoor wall-mounted installation. Final placement should account for the exit path, wall condition, and required emergency light direction.

Installation and Long-Term Use

Install the fixture on a wall with a suitable electrical connection for 100-277V operation. Position the adjustable heads after mounting so the 120 degree distribution is directed toward the required emergency area.

Keep the fixture accessible for testing and service. Confirm that the wall location allows both LED heads to be aimed without obstruction.

How This Fixture Is Commonly Used

For egress lighting and emergency exit lighting, the unit is wall mounted near the required route and the heads are aimed after installation. Placement is based on the path layout and the direction of needed emergency illumination.

In commercial building exit marking and industrial facility exit lighting, installers typically orient each head toward separate portions of the path when the wall location serves more than one direction. Head aiming affects distribution, so final positioning should be completed after the fixture is mounted.

Spacing and fixture count depend on the project layout and required emergency light coverage. The supplied product data does not establish a fixed spacing distance or coverage area.

Safety, Certifications, and Warranty

This emergency light is ETL certified.

The fixture includes a 3 year warranty.

Frequently Asked Questions

Q: What is the emergency output of this fixture?

A: The fixture produces 300 lumens at 5000K while operating at 4 watts.

Q: How long does the battery backup operate?

A: The battery backup provides illumination for up to 90 minutes.

Q: Can the LED heads be aimed after installation?

A: Yes. The LED heads are adjustable and can be directed for the required light distribution.

Q: How should adjustable heads be considered during layout planning?

A: Head direction should be considered with the wall location and required emergency light direction. The supplied product data does not establish a fixed spacing distance or coverage area.

Application Questions and Clarification

Q: Is this fixture appropriate for egress lighting?

A: Yes. Egress lighting is a listed primary application for this wall-mounted emergency light with 90 minute battery backup.

Q: What should be confirmed before placing this fixture for industrial facility exit lighting?

A: Confirm the wall location, required emergency light direction, available 100-277V input voltage, and access for testing and maintenance.

Q: Can this emergency light be dimmed?

A: No. This fixture is not dimmable.

Web ID: 2053

You may also like