3 Watt LED Exit Sign | 90 Minute Battery Backup

SKU: MLLG-LN-LED-EXIT1 Web ID: 1551
Starting at: $29.06

Availability: 306 In Stock Ships 3-5 Days

This 3 Watt LED exit sign is a practical choice for interior commercial and industrial spaces requiring code-compliant, illuminated egress signage with battery backup. Its universal 100V-277V input simplifies installation across various electrical systems, while the included red and green letter panels allow compliance with differing local requirements. The UL 94V-0 flame-rated thermoplastic ABS housing provides essential fire safety for indoor use, and the 90-minute battery backup meets standard emergency duration needs. This fixture is not intended for wet locations.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

306 in stock

    Product total

    Options total

    Sub-Total

    Product Specifications

    UL Listed - Verified for Electrical Safety and Performance

    Key Features

    Brand LED Lighting Supply
    Watts 3
    Voltage 100V-277V
    Dimming No
    Lifespan 50,000 hours
    Mounting Surface
    Fixture Color White
    Frequency (Hz) 50/60
    Power Factor > .90
    THD < 20%

    Durable Construction

    Housing Injection-Molded Thermoplastic ABS
    Certifications UL
    Warranty 2 years

    Measurements

    Dimensions (in) 12 X 7.5 X 4.4

    Product Overview

    This 3-watt LED exit sign provides emergency exit marking with a 90-minute battery backup. It operates on 100-277V power and uses a white injection-molded thermoplastic ABS housing.

    The fixture is surface mounted and measures 12 x 7.5 x 4.4 inches. Its 5000K emergency illumination supports egress lighting and emergency exit lighting locations.

    Core Performance and Output

    The fixture operates at 3 watts on 100-277V, 50/60Hz electrical systems. Power factor is greater than 0.90 and total harmonic distortion is less than 20%.

    Emergency battery backup is rated for 90 minutes. Beam distribution is not specified in the supplied product data.

    This unit is intended for exit marking and emergency illumination rather than general area lighting. Output is limited to the fixture’s 3-watt configuration.

    Adjustability and Control Options

    This exit sign does not include dimming capability. It is intended for fixed surface-mounted operation.

    No control, sensor, remote-head, or adjustable-output options are specified in the supplied product data.

    Longevity and Reliability

    The LED light source has a rated lifespan of 50,000 hours. The emergency battery backup provides 90 minutes of operation.

    Long-term service planning should account for the fixture’s battery backup function and the 2-year warranty period.

    Build Quality and Physical Characteristics

    The housing is made from injection-molded thermoplastic ABS. The fixture is finished in white.

    Overall dimensions are 12 x 7.5 x 4.4 inches. Surface mounting keeps the fixture profile suitable for exit-marking locations where recessed mounting is not specified.

    Where This Product Fits Best

    This exit sign fits indoor life safety and egress marking installations that require a surface-mounted fixture with 100-277V operation and emergency battery backup.

    • emergency exit lighting
    • egress lighting
    • life safety lighting
    • commercial building exit marking
    • industrial facility exit lighting
    • warehouse exit lighting

    The thermoplastic ABS housing is intended for the supplied exit sign applications. UL certified.

    Installation and Long-Term Use

    Surface mounting requires a stable mounting surface and access to 100-277V power. Confirm fixture location, wiring access, and the required exit-marking layout before installation.

    The fixture does not include dimming. Maintenance personnel should include the emergency battery backup function in routine life safety lighting checks.

    How This Fixture Is Commonly Used

    This fixture is surface mounted at designated emergency exit lighting and egress lighting locations. Mounting height is determined by the project exit-marking layout and site requirements.

    Fixture placement follows the required exit and egress layout rather than general illumination spacing. Battery backup operation remains available for 90 minutes when emergency illumination is needed.

    Safety, Certifications, and Warranty

    UL certified.

    The fixture includes a 2-year warranty. It operates on 100-277V at 50/60Hz.

    Frequently Asked Questions

    Q: What voltage does this LED exit sign operate on?

    A: This fixture operates on 100-277V, 50/60Hz power.

    Q: How long does the battery backup operate?

    A: The battery backup is rated for 90 minutes.

    Q: Is this exit sign dimmable?

    A: No. Dimming is not included.

    Q: What mounting method does this fixture use?

    A: This fixture uses surface mounting.

    Application Questions and Clarification

    Q: Is this fixture intended for warehouse exit lighting?

    A: Warehouse exit lighting is included in the supplied application data. The fixture provides surface mounting, 100-277V operation, and 90-minute battery backup.

    Q: What should be confirmed when planning egress lighting placement?

    A: Confirm the exit-marking layout, mounting location, wiring access, and required mounting height. Specific spacing values are not established by the supplied product data.

    Q: Is the fixture UL certified?

    A: UL certified.

    Web ID: 1551

    You may also like