LED Exit Light Combo | Red or Green | Double or Single Sided | Adjustable Heads | 120-277V
865 in stock
Product Specifications
Key Features
| Brand | LED Lighting Supply |
| Input Watts | 2 |
| Output Watts | 3 Max |
| Voltage | 120--277V |
| Lifespan | 50,000 hours |
| Mounting | Surface | Wall |
| Fixture Color | White |
| Frequency (Hz) | 50/60 |
| Housing | Injection-Molded Thermoplastic ABS |
| IP Rating | Damp Location |
| Certifications | UL |
| Operating Temp | 32°F to 104°F |
| Dimensions (in) | 15.7 L X 1.75 W X 7.25 H |
| Emergency Backup Time | 90 Minutes |
| Lettering | Red or Green | With or Without Arrows |
Fire-resistant with customizable parts included for either red or green lettering, with or without arrows, single or double sided.
Product Overview
This LED exit light combo provides illuminated exit marking with emergency backup for egress lighting and life safety lighting. It supports red or green lettering, optional directional arrows, and single- or double-sided configuration.
The thermoplastic ABS housing is intended for surface or wall mounting in damp locations. The 90-minute emergency backup supports emergency exit lighting when normal power is interrupted.
Core Performance and Output
This unit operates on 120-277V, 50/60 Hz power. Input power is 2 watts, with 3 watts maximum output power.
Lighting efficiency and beam-distribution values are not provided. Output is intended for exit-sign visibility rather than general-area illumination.
Adjustability and Control Options
Adjustable heads are included with the exit light combo configuration. The fixture supports red or green lettering, with or without directional arrows.
Single-sided and double-sided sign configurations are available. No dimming or external control compatibility is provided in the supplied product data.
Longevity and Reliability
The listed service life is 50,000 hours. Emergency operation is rated for 90 minutes.
The fixture is rated for operation from 32 F to 104 F. It is intended for damp-location conditions.
Build Quality and Physical Characteristics
The housing is injection-molded thermoplastic ABS with a white finish. The fixture is fire-resistant.
Overall dimensions are 15.7 inches long by 1.75 inches wide by 7.25 inches high. The shallow profile supports surface and wall mounting where exit marking must remain visible.
Where This Product Fits Best
This exit light combo fits indoor egress routes and exit locations requiring illuminated marking with emergency backup. Its damp-location rating supports areas not exposed to direct weather.
- emergency exit lighting
- egress lighting
- life safety lighting
- code compliance lighting
- commercial building exit marking
- industrial facility exit lighting
- warehouse exit lighting
Red or green lettering and directional arrow options support exit-path identification where the egress route changes direction. Surface and wall mounting allow the sign location to follow the established egress plan.
Installation and Long-Term Use
The fixture mounts on a surface or wall and operates across a 120-277V supply range. Confirm the selected lettering color, arrow direction, and sign-sided configuration before installation.
Maintenance should include periodic review of sign visibility and emergency backup operation. The unit is intended for damp locations and should remain within its listed operating temperature range.
How This Fixture Is Commonly Used
For egress lighting, emergency exit lighting, and life safety lighting, the sign is positioned where occupants can identify the exit path. Mounting height follows the facility egress plan and local code requirements; no specific mounting height is established in the supplied data.
Commercial building exit marking, industrial facility exit lighting, and warehouse exit lighting layouts use arrow direction and single- or double-sided visibility based on the viewing approach. A double-sided configuration can serve opposing viewing directions, while arrow selection follows the required exit route.
Safety, Certifications, and Warranty
This LED exit light combo is UL listed. It provides 90 minutes of emergency backup operation.
The housing is fire-resistant thermoplastic ABS and the fixture is rated for damp locations. Warranty terms are not provided in the supplied product data.
Frequently Asked Questions
Q: What voltage does this LED exit light combo operate on?
A: It operates on 120-277V, 50/60 Hz power.
Q: How long is the emergency backup time?
A: The emergency backup time is 90 minutes.
Q: Can this unit use red or green exit lettering?
A: Yes. It supports red or green lettering.
Q: What mounting methods are available?
A: The fixture supports surface mounting and wall mounting.
Q: What sign configuration options should be considered when planning exit marking?
A: The unit is available in single-sided or double-sided configurations, with or without directional arrows. Lettering color can be red or green.
Application Questions and Clarification
Q: Is this fixture intended for egress lighting and emergency exit lighting?
A: Yes. The fixture is designed for egress lighting and emergency exit lighting with a 90-minute emergency backup.
Q: Can this unit be used for warehouse exit lighting?
A: Warehouse exit lighting is a valid application. Final placement should follow the facility egress plan and applicable code requirements.
Q: Is this fixture suitable for damp locations?
A: Yes. The supplied product data lists the fixture for damp locations.
Q: What should be confirmed before selecting arrow direction?
A: Confirm the required exit route and viewing direction. The fixture is available with or without arrows.
Web ID: 2797