40 Foot Fiberglass Piling | 12 Inches Round
Out of stock
Product Specifications
Key Features
| Brand | LED Lighting Supply |
| Total Height (ft) | 38.83 |
| Material | Fiberglass Piling |
| Pole Weight (lbs) | 656 |
| Pole Diameter (in) | 11.85 |
| Pole Finish | Fluoropolymer Coating |
| Pole Color | Bronze | Black | White | Gray | Custom |
| Pole Gauge | .532 in |
| Pole Installation | Direct Burial |
| Warranty | 7 years |
Note: The nominal size of the piling is 40 feet by 12 inches, the actual measurement is 38 feet 10 inches with an 11.85 inch diameter.
Delivery is made with a flatbed truck and the customer is responsible for offloading. Offloading requires a forklift or appropriate similar machine (customer supplied). Customer is responsible for any costs associated with delivery rescheduling because of improper scheduling or not having the proper offloading equipment available at the time of delivery.
Pricing: Does not include cost of shipping. Shipping is available to the lower 48 USA states. We can supply a budgetary shipping quote or a firm shipping quote that is good for 14 days to your delivery location.
Disclaimer: LED Lighting Supply is not responsible for improper loading (ie what is mounted to the piling), installation costs, or foundation design of piling. Dimensions and specifications of pilings are subject to change without notice.
Please be advised that our fiberglass pilings are covered solely by a 7-year workmanship warranty, which ensures that the pilings are free from defects from the manufacturing process, and structural integrity, for a period of 7 years from the date of purchase. This warranty does not cover damage resulting from external factors, misuse, or normal wear and tear.
Product Overview
This 40 foot fiberglass piling is a round, direct-burial structural member with a nominal 12 inch diameter. The actual overall length is 38.83 feet, and the actual diameter is 11.85 inches.
The piling is intended for marine structures, dock structures, pier construction, and waterfront structures. Its fiberglass construction and fluoropolymer coating finish are suited to projects requiring a non-metal structural piling.
Core Performance and Output
This piling provides structural length and direct-burial installation rather than light output. It weighs 656 pounds and has a .532 inch wall gauge.
Structural capacity, wind loading, fixture support limits, embedment depth, and exposed height are not established by the supplied product data. Project engineering must determine those requirements before installation.
Adjustability and Control Options
This is a fixed-length fiberglass piling with no adjustable operating settings or controls. The supplied configuration is a nominal 40 foot by 12 inch round piling.
Available finish colors are bronze, black, white, gray, and custom. Color selection does not change the supplied physical dimensions or direct-burial installation method.
Longevity and Reliability
The piling has a fluoropolymer coating finish over its fiberglass construction. The supplied warranty period is seven years.
Long-term performance depends on proper handling, direct-burial installation, and project-specific structural design. Inspect the piling for damage before placement and after site events that could affect the structure.
Build Quality and Physical Characteristics
This piling is made from fiberglass and has a round 11.85 inch outside diameter. Its nominal size is 40 feet by 12 inches.
The actual overall height is 38 feet 10 inches. The piling weighs 656 pounds, so lifting and placement planning should account for its handling weight and full length.
Where This Product Fits Best
This piling fits direct-burial structural work associated with waterfront and marine construction. Its length and round fiberglass form are appropriate where a piling is part of the planned structural system.
- dock structures
- pier construction
- waterfront structures
- marine structures
- marina construction
- boardwalk structures
Final fit depends on the project structural design, burial requirements, loading conditions, and connection details. The supplied data does not establish engineered load ratings or marine exposure performance.
Installation and Long-Term Use
This piling installs by direct burial. Installation planning must account for the 38.83 foot overall length, 656 pound weight, site access, lifting equipment, and placement control.
Confirm burial depth, exposed height, alignment, and structural connections through the project design. These values are not provided in the supplied product data.
How This Fixture Is Commonly Used
In dock structures, pier construction, and waterfront structures, the piling is placed as part of the planned direct-burial structural layout. The 38.83 foot total height is the supplied physical length, not the installed exposed height.
Spacing and layout follow the project structural plan and required loading conditions. A larger spacing pattern can reduce piling count, but the supplied data does not establish allowable spacing or capacity.
Safety, Certifications, and Warranty
No certifications are provided in the supplied product data. The warranty is seven years.
Use lifting, handling, and installation practices appropriate for a 656 pound fiberglass piling. Structural and burial requirements must be confirmed before installation.
Frequently Asked Questions
Q: What are the actual dimensions of this nominal 40 foot by 12 inch piling?
A: The actual overall height is 38.83 feet, or 38 feet 10 inches. The actual diameter is 11.85 inches.
Q: What material is this piling made from?
A: This piling is made from fiberglass.
Q: How is this piling installed?
A: The supplied installation method is direct burial.
Q: What finish colors are available?
A: Available colors are bronze, black, white, gray, and custom.
Q: Does the supplied data establish piling spacing or layout requirements?
A: No. Spacing, layout, burial depth, and structural loading requirements are not established by the supplied product data.
Application Questions and Clarification
Q: Is this piling applicable to dock structures and pier construction?
A: Yes. Dock structures and pier construction are listed applications for the Pilings product family.
Q: What should be confirmed for waterfront structures before installation?
A: Confirm the project structural design, burial requirements, exposed height, loading conditions, and connection details. These requirements are not established by the supplied product data.
Q: Can this piling be used for marina construction?
A: Marina construction is listed as a secondary application for the Pilings product family. Final suitability depends on the project structural requirements.
Web ID: 2776


