100 Watt High Temperature Explosion Proof LED Light | 10000 Lumens | Class 1 Div 2 | 5000K | 120V | Rated to 194F
Product Specifications
UL Specs
- UL 844 Hazardous Locations
- Class I, Division 2, Groups A, B, C, D
- Class II, Division 1, Groups E, F, G
- Class II, Division 2, Groups F, G
- Class III
- UL 1598 Suitable for Wet Locations
- UL 1598A Marine Outside Type
- ABS
Key Features
| Brand | LED Lighting Supply |
| Watts | 100 |
| Lumens | 10000 |
| Lumens Per Watt | 100 |
| Replaces | 400 Watt Metal Halide |
| Voltage | 120V |
| Color Temperature | 5000K |
| CRI | 70+ |
| Dimming | No |
| Beam Angles (Std) | 120° |
| Beam Angles (Opt) | 40° or 60° or 90° |
| Optics | Tempered Glass Lens |
| Lifespan | 50,000 (L70) hours |
| Mounting | Yoke or 3/4 in NPT Pendant |
| Fixture Color | Gray |
| Frequency (Hz) | 50/60 |
| Power Factor | >.95 |
| THD | < 10% |
Durable Construction
| Housing | Copper Free Aluminum |
| IP Rating | IP66 |
| IK Rating | IK10 |
| Surge Protection | 10kV |
| Operating Temperature | -40°F to 194°F |
| Certifications | ETL | Rebate Eligible |
| Warranty | 5 years |
Measurements
| Dimensions (in) | 14 D X 11.3 H |
| Weight (lbs) | 26 |
Download IES Files
Product Lighting Layout Estimator
Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.
Project Inputs
Estimated Results
Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.
Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.
Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.
Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.
This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.
Product Overview
This 100-watt high temperature explosion proof LED light produces 10,000 lumens at 5000K for hazardous industrial areas exposed to sustained heat. It is rated for operation from -40F to 194F and provides a 400-watt metal halide replacement option.
The fixture is built for high temperature facility lighting where hazardous-location classifications, wet-location suitability, impact resistance, and elevated ambient temperatures must be addressed together. Yoke and 3/4 in NPT pendant mounting support different structural mounting conditions.
Core Performance and Output
The fixture delivers 10,000 lumens at 100 watts, with an efficacy of 100 lumens per watt. A standard 120-degree beam angle provides broad distribution, while 40-degree, 60-degree, and 90-degree optics are available for more controlled coverage.
It operates on 120V, 50/60 Hz power, with a power factor above 0.95 and THD below 10%. The 5000K color temperature and 70+ CRI support general industrial visibility.
The 120-degree optic can place excessive light at lower mounting heights. Narrower optics provide more concentrated output but require layout review to maintain uniformity between fixtures.
Adjustability and Control Options
This fixture is non-dimming. It operates at a fixed 100-watt output on 120V.
Optical selection provides the primary adjustment method. The standard 120-degree distribution suits broad coverage, while 40-degree, 60-degree, and 90-degree options allow the beam pattern to match the installation layout.
Longevity and Reliability
The LED system is rated for 50,000 L70 hours. This rating indicates the point at which light output is expected to maintain 70 percent of initial output.
Integrated 10kV surge protection helps protect the fixture from electrical surge events. The stated operating range extends from -40F to 194F.
Build Quality and Physical Characteristics
The housing is copper-free aluminum with a gray finish. A tempered glass lens protects the optical system.
The fixture is IP66 rated and IK10 rated. It measures 14 inches in diameter by 11.3 inches high and weighs 26 pounds.
Yoke mounting and 3/4 in NPT pendant mounting are available. The mounting structure and connection method must support the fixture weight and the selected mounting configuration.
Where This Product Fits Best
This fixture fits elevated-temperature industrial areas requiring hazardous-location lighting equipment. Its 194F maximum operating temperature supports facilities with heat exposure beyond standard industrial lighting conditions.
- industrial furnace area lighting
- steel mill lighting
- foundry lighting
- power plant and energy site lighting
- boiler room lighting
- heat treatment facility lighting
The IP66 rating supports wet locations, and the copper-free aluminum housing provides a durable enclosure for industrial conditions. The hazardous-location classifications must match the area classification before installation.
Installation and Long-Term Use
The fixture installs with either a yoke or 3/4 in NPT pendant mount. Pendant mounting is commonly used where the fixture needs to hang below structural elements, while yoke mounting supports directional aiming.
Mounting height and optic selection determine the final layout. Wider optics support broader spacing patterns, while narrower optics concentrate output and may require a more deliberate fixture arrangement.
In high temperature facility lighting, fixture placement must account for the actual ambient temperature at the mounting location. Heat near furnaces, boilers, kilns, and heat treatment equipment can differ from the general room temperature.
How This Fixture Is Commonly Used
In industrial furnace area lighting, steel mill lighting, and foundry lighting, fixtures are positioned around process equipment and structural bays where elevated temperature exposure is present. Yoke mounting allows aiming where directional coverage is required.
For power plant and energy site lighting, boiler room lighting, and heat treatment facility lighting, pendant-mounted fixtures can be arranged along equipment areas or structural runs. Layout patterns depend on mounting height, selected optic, target light levels, and obstructions.
A wider beam can reduce the number of fixture locations needed for broad coverage, but it can also reduce control over light placement near equipment.
Safety, Certifications, and Warranty
UL 844 Hazardous Locations. Class I, Division 2, Groups A, B, C, D. Class II, Division 1, Groups E, F, G. Class II, Division 2, Groups F, G. Class III.
UL 1598 Suitable for Wet Locations. UL 1598A Marine Outside Type. ABS. ETL. Rebate Eligible.
This fixture includes a 5-year warranty.
Frequently Asked Questions
Q: What is the maximum operating temperature of this fixture?
A: The fixture is rated for operation up to 194F.
Q: What hazardous-location classifications does this fixture carry?
A: It is UL 844 listed for Class I, Division 2, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class II, Division 2, Groups F, G; and Class III.
Q: What mounting methods are available?
A: The fixture is available with yoke mounting or 3/4 in NPT pendant mounting.
Q: Can the beam distribution be changed for the lighting layout?
A: The standard beam angle is 120 degrees. Optional 40-degree, 60-degree, and 90-degree beam angles are available.
Application Questions and Clarification
Q: Is this fixture appropriate for industrial furnace area lighting?
A: The fixture is rated for operation up to 194F and is listed for hazardous locations. Final fit depends on the actual ambient temperature and area classification at the mounting location.
Q: What should be reviewed for foundry lighting layouts?
A: Mounting height, selected beam angle, target light levels, obstructions, ambient temperature, and hazardous-location classification affect the layout.
Q: Can this fixture be used in boiler room lighting where wet conditions are present?
A: The fixture is UL 1598 suitable for wet locations and carries an IP66 rating. Area classification and ambient temperature must also match the fixture ratings.
Web ID: 2303