Need help choosing the right Product?
Get expert recommendations and a custom lighting plan within 1 day! Get Product Recommendations ➜
10 Foot HVLS Ceiling Fan | 6 Blades | 6,375 Square Foot Coverage | 15,000 CFM
Product Description
Key Features
- Diameter: 10 ft
- Speed: Variable
- Phase: 1P | 3P
- Color: Black
- Blade Material: Aluminum
- Controller: Wall Mounted VFD
- Blades: 6
- AMPs: 110-120V 1P 9.6A | 208-240V, 1P: 5.7A | 208-240V, 3P: 3.90A | 460-480V, 3P: 1.8A
- Frequency: 60 Hz
- Fan CFM: 15,000
- Coverage Area: 6,375 square feet
- RPM: 44
- Sound Level: <57 dBA
- Fan Weight: 95 lbs
- Motor Size: 0.5 HP Gear Drive
- Downrod: 1 ft, 2 ft, 3 ft, and 6 ft Extensions Available
- Mounting: I-Beam | Z-Purlins | Open Joist
- Voltage: 208V-240V | 110V-120V | 460V-480V
- Minimum Mounting Height: 10 Feet
- Minimum Ceiling Clearance: 5 Feet
- Minimum Horizontal Clearance: 2 Feet
- Warranty: years
The LLS-HVLS-FAN-10FT-6B is a 10 foot diameter 6 blade high volume low speed (HVLS) ceiling fan. It is ideal for industrial grade and commercial spaces with open floor plans. It includes a NEMA 1 wall mounted VFD for controlling your unit. The controller features a safety disconnect, on/off toggle, and speed regulator. Safety features include, safety cable, hub clips, hub retainer, dual-method fastening of all joined components, and integrated sprinkler shut-off.
This 10 foot HVLS fan is perfect for installations in gyms, warehouses, work shops, hangars, manufacturing facilities, and factories.
Web ID: 2323
Product Overview
This is a 10 foot diameter, 6 blade HVLS ceiling fan designed for large open spaces. The fan delivers up to 15,000 CFM and covers up to 6,375 square feet. It operates at a maximum speed of 44 RPM and produces less than 57 dBA of sound during operation.
The fan uses a 0.5 HP gear drive motor and features aluminum blades. It is controlled by a wall-mounted NEMA 1 VFD controller, which provides variable speed adjustment, an on/off toggle, and a safety disconnect. The fan weighs 95 lbs.
Mounting options include I-Beam, Z-Purlins, and Open Joist. Downrod extensions are available in 1 ft, 2 ft, 3 ft, and 6 ft lengths to accommodate different ceiling heights and installation requirements.
Minimum mounting height is 10 feet, with a minimum ceiling clearance of 5 feet and a minimum horizontal clearance of 2 feet required for safe operation.
Where This Product Fits Best
This 10 foot HVLS fan is suitable for industrial and commercial environments with open floor plans. Typical applications include warehouses, manufacturing facilities, distribution centers, hangars, gyms, and large workshops.
The fan is designed for spaces where consistent air movement is needed across a wide area. It is appropriate for locations with ceiling heights that allow for the required clearances and where structural mounting points such as I-Beams, Z-Purlins, or Open Joists are available.
It is not intended for use in confined areas or spaces with low ceilings. The fan is best suited for environments where noise levels below 57 dBA are acceptable and where a wall-mounted controller can be installed within reach of facility staff.
Performance and Functional Considerations
The fan provides a maximum airflow of 15,000 CFM, supporting air movement over an area up to 6,375 square feet. The variable speed controller allows adjustment to match changing conditions or preferences within the facility.
Aluminum blades reduce overall weight and resist corrosion in typical indoor environments. The 0.5 HP gear drive motor is sized for continuous operation in commercial and industrial settings.
The fan operates on multiple voltage options: 110-120V single phase, 208-240V single or three phase, and 460-480V three phase. This allows compatibility with a range of electrical systems commonly found in large facilities.
Sound output is rated below 57 dBA, which is suitable for most industrial and commercial spaces where moderate background noise is present.
Installation and Long-Term Use
Mounting options include I-Beam, Z-Purlins, and Open Joist, supporting installation in a variety of building structures. Downrod extensions in multiple lengths allow the fan to be positioned at the correct height for optimal performance and clearance.
Minimum mounting height is 10 feet, with at least 5 feet of clearance from the ceiling and 2 feet of horizontal clearance from obstructions. These requirements must be met for safe and effective operation.
The wall-mounted VFD controller provides direct access for speed adjustment and includes a safety disconnect. Safety features include a safety cable, hub clips, hub retainer, dual-method fastening of all joined components, and an integrated sprinkler shut-off.
Routine inspection of mounting hardware and safety features is recommended to ensure continued safe operation over time.
How This Fixture Is Commonly Used
After installation, the fan is typically operated using the wall-mounted VFD controller. Facility staff can adjust the speed as needed to maintain comfort or support process requirements.
The variable speed function allows you to increase or decrease airflow based on occupancy, temperature, or other operational needs. The on/off toggle and safety disconnect provide straightforward control and isolation for maintenance.
Once installed, the fan requires minimal day-to-day interaction beyond periodic speed adjustments and routine safety checks. The aluminum blades and gear drive motor are designed for long-term use in demanding environments.
Clearances and mounting height must be maintained throughout the life of the fan to ensure safe operation and effective air movement.
Safety, Certifications, and Warranty
Safety features include a safety cable, hub clips, hub retainer, dual-method fastening of all joined components, and an integrated sprinkler shut-off.
The fan is supplied with a NEMA 1 rated wall-mounted VFD controller.
Warranty coverage is provided by LED Lighting Supply. Refer to the warranty documentation for terms and duration.
Frequently Asked Questions
What voltages is this fan compatible with?
This fan operates on 110-120V single phase, 208-240V single or three phase, and 460-480V three phase.
What is the maximum airflow output?
The fan delivers up to 15,000 CFM.
What mounting methods are supported?
Mounting options include I-Beam, Z-Purlins, and Open Joist.
What is the warranty coverage?
Warranty is provided by LED Lighting Supply. Refer to the warranty documentation for details.
What is the minimum required mounting height?
Minimum mounting height is 10 feet, with at least 5 feet of ceiling clearance and 2 feet of horizontal clearance.
Is this fan suitable for use in areas with fire sprinklers?
The fan includes an integrated sprinkler shut-off feature.
Application Questions and Clarification
This product description reflects the provided specifications, ratings, and configuration options. For questions related to site-specific conditions, electrical compatibility, control integration, or application requirements not addressed in the provided data, our team is available to provide clarification.