Product Specifications
Key Features
| Brand | LED Lighting Supply |
| Total Height (ft) | 30 |
| Height Above Grade (ft) | 25 |
| Buried Depth Below Grade (ft) | 5 |
| ANSI Class | Class 6 |
| Material | Wood Southern Yellow Pine |
| Pole Weight (lbs) | 510-605 |
| Min Pole Top Circ (in) | 17 |
| Min Circ 6ft from Butt (in) | 25 |
| Min Pole Top OD (in) | 5.4 |
| Pole OD 6ft From Butt (in) | 8 |
| Treatment | CCA |
| Pole Installation | Direct Burial |
| Warranty | 1 year |
Our 30 foot Class 6 CCA Treated Southern Yellow Pine Poles are grown, debarked, and treated in the United States. They are manufactured to ANSI O5.1 specification. 30 ft utility poles are treated to the latest American Wood Preservers Association standards to prevent decay and damage from insects.
Cross arms are available for our Southern Yellow Pine poles as an optional accessory. Configuration and sizing are determined based on project requirements, as well as the height and class of the selected pole. We offer both 8-foot and 10-foot cross arms, our product specialists can help confirm the appropriate size for your application.
Delivery is made with a flatbed truck and the customer is responsible for offloading. Offloading requires a forklift or appropriate similar vehicle to offload – customer supplied. Customer is responsible for any costs associated with delivery rescheduling because of improper scheduling or not having the proper offloading equipment available at the time of delivery.
Pricing: Does not include cost of shipping. Shipping is available to the lower 48 USA states. We can supply a budgetary shipping quote or a firm shipping quote that is good for 14 days to your delivery location.
Disclaimer: LED Lighting Supply is not responsible for improper loading (ie what is mounted to the pole), installation costs, or foundation design of light poles. Dimensions and specifications of poles are subject to change without notice but the pole top and butt dimensions will always be within ANSI specifications. Wood poles are the ideal option for most field projects as concrete poles require more frequent maintenance and replacement. While our main product line is southern yellow pine, we at times are able to offer other species including Douglas fir and red pine. CCA treatment generally will result in the poles being free of insects for decades to come.
Please be advised that our wood poles are covered solely by a 1-year workmanship warranty, which ensures that the poles are free from defects from the manufacturing process, and structural integrity, for a period of one year from the date of purchase. This warranty does not cover damage resulting from external factors, misuse, or normal wear and tear.
Download our Pole Circumference Chart for Wood Poles
Product Overview
This 30-foot wood utility pole is a Class 6 Southern Yellow Pine pole for direct-burial light pole installations. It provides 25 feet of height above grade with a 5-foot buried depth.
The pole is CCA treated and manufactured to ANSI O5.1 specification. Its size and installed height suit lower-height sports field lighting layouts where wood pole construction and direct burial are part of the site design.
Core Performance and Output
Structural performance is based on the Class 6 pole classification, 30-foot overall length, and direct-burial installation. The pole weighs 510 to 605 pounds and has a minimum 17-inch top circumference and 25-inch circumference measured 6 feet from the butt.
The minimum pole top outside diameter is 5.4 inches. The outside diameter 6 feet from the butt is 8 inches. Fixture head loading, crossarm configuration, and lighting layout must remain within the structural requirements of the selected pole and project design.
Adjustability and Control Options
This pole does not include integral lighting controls or electrical components. Controls, wiring, fixtures, and electrical distribution are determined separately by the lighting system design.
Optional 8-foot and 10-foot cross arms are available. Crossarm size and configuration depend on the project requirements and the selected pole height and class.
Longevity and Reliability
The Southern Yellow Pine construction is CCA treated. Treatment follows current American Wood Preservers Association standards for protection against decay and insect damage.
Direct-burial installation places the lower portion of the pole below grade, so site excavation, backfill condition, and pole alignment affect long-term stability. The warranty is 1 year.
Build Quality and Physical Characteristics
The pole is grown, debarked, and treated in the United States. It uses Southern Yellow Pine wood construction with a Class 6 ANSI rating.
Total pole length is 30 feet. The installed configuration places 25 feet above grade and 5 feet below grade. Weight varies from 510 to 605 pounds.
Where This Product Fits Best
This pole fits direct-burial lighting structures for outdoor athletic and recreational properties that use wood utility poles at a 25-foot above-grade height.
- sports field lighting
- baseball field lighting
- soccer field lighting
- football field lighting
- driving range lighting
- recreational field lighting
The CCA-treated wood construction is intended for installed conditions where the pole is buried below grade. Pole class, fixture loading, crossarm selection, and field layout need to align with the project structural design.
Installation and Long-Term Use
This pole installs by direct burial with 5 feet below grade. Handling plans should account for the 510 to 605 pound pole weight and the full 30-foot pole length.
Installers need to maintain pole plumb during placement and backfill. Cross arms, fixture brackets, wiring, and luminaires are separate components that must be coordinated with the completed pole assembly.
How This Fixture Is Commonly Used
For baseball field lighting, soccer field lighting, football field lighting, and recreational field lighting, the pole provides 25 feet of mounting elevation above grade. Lighting equipment is mounted at the pole top or on an optional crossarm assembly based on the project design.
Field layouts use multiple poles positioned to distribute light across the selected sports field or driving range lighting area. Pole spacing and fixture aiming vary with the lighting layout, target light levels, fixture output, and crossarm configuration.
Safety, Certifications, and Warranty
This pole is manufactured to ANSI O5.1 specification. The CCA treatment follows current American Wood Preservers Association standards.
The warranty is 1 year. Direct-burial installation, fixture loading, crossarm selection, and electrical work must follow the project requirements.
Frequently Asked Questions
Q: What is the installed height above grade?
A: The pole provides 25 feet of height above grade when installed with 5 feet buried below grade.
Q: How is this wood pole installed?
A: The pole is installed by direct burial.
Q: What wood species and treatment does this pole use?
A: The pole is Southern Yellow Pine with CCA treatment.
Q: Are cross arms available for this pole?
A: Optional 8-foot and 10-foot cross arms are available. Crossarm configuration and size depend on project requirements and the selected pole height and class.
Q: What should be reviewed when planning a sports field lighting pole layout?
A: Review the 25-foot above-grade height, direct-burial installation, pole class, fixture loading, crossarm configuration, and project lighting layout.
Application Questions and Clarification
Q: Is this pole appropriate for baseball field lighting and football field lighting?
A: Baseball field lighting and football field lighting are valid applications for this wood light and utility pole family. Final fit depends on the project structural design, fixture loading, and lighting layout.
Q: What pole dimensions affect fixture and crossarm planning?
A: The minimum pole top outside diameter is 5.4 inches, and the outside diameter 6 feet from the butt is 8 inches. The minimum pole top circumference is 17 inches.
Q: What should be considered before direct-burial installation?
A: The installation uses 5 feet of buried depth. Pole handling, excavation, backfill, alignment, fixture loading, and crossarm configuration need to be addressed in the project requirements.