Menu
Search Icon

Need help choosing the right Product?

Get expert recommendations and a custom lighting plan within 1 day! Get Product Recommendations ➜

44 Watt 8 Foot T8 LED Tube | 5700 Lumens | 6500K | 100-277V | Clear Lens | 25 Pack

SKU: LLS-LN-8FT-T8-44-65-C-25P | Web ID: 2655
Starting at: $500.00
Availability: 31 In Stock Ships 3-5 Days

31 in stock

Get your quote within 1 hour!
This 8 foot T8 LED tube is a strong choice for facilities seeking a direct, energy-efficient replacement for 8 foot fluorescent lamps, delivering 5700 lumens at 44 watts with a high efficacy of 130 lumens per watt. Its 6500K daylight white output and 120 degree beam angle provide broad, clear illumination ideal for warehouses, manufacturing areas, and distribution centers where visibility and color clarity are critical. The ETL listing, 50,000 hour rated lifespan, and 5 year warranty support long-term reliability, while compatibility with 100V to 277V systems simplifies installation in most commercial and industrial environments.

Dwayne Kula | President, CTO and Founder

Product Description

ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive Programs5 Year Unlimited Usage Warranty

Key Features

  • Watts: 44
  • Lumens: 5700
  • Lumens Per Watt: 130
  • Replaces: 8ft Fluorescent
  • Voltage: 100V-277V
  • Color Temperature: 6500K
  • CRI: 80+
  • Dimming: No
  • Beam Angles (Std): 120°
  • Optics: Clear Lens
  • Lifespan: 50,000 hours
  • Frequency (Hz): 50 / 60 hz
  • Power Factor: > .90
  • THD: < 18%

Durable Construction

  • Certifications: ETL | Rebate Eligible
  • Warranty: 5 years

Measurements

  • Dimensions (in): 8 ft
  • Weight (lbs): 3 lbs

Request IES Files

Web ID: 2655

Product Overview

The 44 Watt 8 Foot T8 LED Tube is designed for direct replacement of 8-foot fluorescent tubes in retrofit applications. This tube delivers 5700 lumens at 6500K, providing high-output, daylight-white illumination for linear strip fixtures and troffers. Typical installations include office, classroom, and commercial workspace retrofits where consistent, efficient lighting is required.

This tube operates on 100-277V input and is supplied in a 25-pack for large-scale projects. The clear lens maximizes delivered lumens, making it suitable for environments where high visibility and uniformity are important. Common mounting methods include surface or suspended installation in existing linear fixtures.

Core Performance and Output

This tube produces 5700 lumens at 44 watts, achieving 130 lumens per watt. The 6500K color temperature provides a crisp, daylight appearance suitable for task-oriented environments. The 120° beam angle ensures broad, even coverage in open or lensed fixtures.

Performance is optimized for mounting heights typical of office, classroom, and utility retrofits?generally 8 to 14 feet. At lower mounting heights, output may be excessive for small rooms or corridors. Uniformity can be affected by fixture spacing and lens type in retrofit scenarios.

Adjustability and Control Options

This tube is non-dimmable and operates at full output when powered. No onboard controls or external dimming compatibility are provided. The tube is compatible with standard on/off switching and occupancy sensors when installed in suitable fixtures.

Beam distribution is fixed at 120°, with no optical adjustment. The clear lens maximizes lumen output but does not provide glare control or diffusion beyond the fixture?s existing lens or cover.

Longevity and Reliability

Rated for 50,000 hours of operation, this tube is designed for long-term use in commercial and institutional settings. The solid-state LED design eliminates common fluorescent failure points such as ballast and filament issues.

Power factor exceeds 0.90 and total harmonic distortion is below 18%, supporting stable electrical performance. The tube is suitable for continuous operation in environments with standard ambient temperatures.

Build Quality and Physical Characteristics

This 8-foot tube weighs 3 lbs and is constructed for compatibility with standard linear strip and troffer fixtures. The clear lens is impact-resistant and designed for maximum light transmission. The tube is supplied in a 25-pack for bulk retrofit projects.

Housing and end caps are engineered for secure fitment in retrofit applications. The tube is not rated for wet locations or enclosed fixture use beyond standard commercial interiors.

Where This Product Fits Best

This tube is intended for indoor retrofit projects where fluorescent tubes are being replaced with LED for improved efficiency and maintenance reduction. Typical environments include offices, classrooms, retail spaces, and utility areas. It is also suitable for healthcare support areas and municipal building retrofits where consistent, high-output lighting is required.

  • office lighting retrofit
  • classroom lighting retrofit
  • retail lighting retrofit
  • utility area lighting retrofit
  • warehouse aisle lighting retrofit
  • healthcare support lighting retrofit
  • municipal building retrofit
  • corridor lighting retrofit

Best suited for dry, climate-controlled interiors with standard ceiling heights. Not intended for high humidity, wet locations, or environments requiring NSF or vapor-tight ratings.

Installation and Long-Term Use

Installation involves retrofitting existing 8-foot linear fixtures. The tube is compatible with direct-wire (ballast bypass) configurations; verify fixture wiring and disconnect or remove ballasts as required. Secure fitment is achieved using standard lamp holders.

Routine maintenance is minimal due to the long LED lifespan. Periodic cleaning of the lens and fixture is recommended to maintain light output. Replacement is straightforward and does not require specialized tools.

How This Fixture Is Commonly Used

Commonly installed in continuous rows or single runs in linear strip fixtures, troffers, or suspended channels. Mounting heights typically range from 8 to 14 feet, depending on ceiling height and application.

Spacing and fixture count are determined by target light levels and room geometry. Higher output per tube can reduce the number of fixtures needed, but may increase glare in low-ceiling or small spaces.

Safety, Certifications, and Warranty

This tube is ETL certified and rebate eligible. It is rated for operation on 100-277V circuits and meets commercial electrical safety standards. The product includes a 5-year warranty covering manufacturing defects and performance.

No hazardous materials are present. The tube is suitable for use in environments where standard commercial safety certifications are required.

Frequently Asked Questions

Q: What is the recommended mounting height for this 8-foot LED tube?

A: Typical mounting heights range from 8 to 14 feet, depending on the application and desired light levels.

Q: Can this tube be installed in fixtures with existing ballasts?

A: This tube is designed for direct-wire (ballast bypass) installation. Ballasts should be removed or bypassed before installation.

Q: Is this tube dimmable?

A: No, this tube is not dimmable and operates at full output when powered.

Q: What is the expected lifespan of this tube?

A: The rated lifespan is 50,000 hours under normal operating conditions.

Q: How many tubes are included in a pack?

A: Each pack contains 25 tubes.

Q: Are these tubes suitable for use in damp or wet locations?

A: No, these tubes are intended for dry, indoor environments only.

Q: How should I plan fixture spacing when retrofitting with these tubes?

A: Fixture spacing should be based on target light levels, ceiling height, and room layout. Higher output may allow for wider spacing, but glare and uniformity should be considered.

Application Questions and Clarification

Q: Can this tube be used in healthcare support areas?

A: Yes, this tube is suitable for healthcare support lighting retrofit applications in dry, non-patient care areas.

Q: Is this tube appropriate for municipal building retrofits?

A: Yes, it is commonly used in municipal building retrofit projects where 8-foot fluorescent tubes are being replaced.

Q: Does this tube fit standard 8-foot linear strip fixtures?

A: Yes, it is designed for compatibility with standard 8-foot linear strip and troffer fixtures using G13 lamp holders.

Q: Is this tube recommended for corridor lighting retrofits?

A: Yes, it is suitable for corridor lighting retrofit projects, provided the output is appropriate for the space.