80 Watt Explosion Proof 2×4 Low Profile Linear LED Light | 11200 Lumens | Class 1 Div 2 | 5000K | 100-277V

SKU: MLLG-E-LED-EXPLP24-80-50-C1D2 Web ID: 1931
Starting at: $1,404.60

 

Built to Order 8-10 Weeks

The 80 Watt Explosion Proof 2×4 Low Profile Linear LED Light is ideal for hazardous locations, such as paint booths, due to its UL 844 and Class I/II/III certifications. Delivering 11,200 lumens at 5000K, it efficiently replaces 250W metal halides, offering significant energy savings. Its IP66 and IK09 ratings ensure durability in harsh environments, while versatile mounting options enhance installation flexibility. With a 50,000-hour lifespan and a 5-year warranty, it promises reliability and long-term performance.

Neil Peterson | CEO and Chief Lighting Specialist

Product Specifications

UL Listed - Verified for Electrical Safety and PerformanceRebate Eligible - Qualifies for Energy Incentive ProgramsNSF Certified - Sanitary and Food-Safe for Clean EnvironmentsClass 1 Division 2 - UL844 Certified for Explosive Atmospheres5 Year Unlimited Usage Warranty

UL Specs

  • UL 844 Hazardous Locations
  • Class 1, Division 2, Groups A,B,C,D
  • Class 2, Division 1, Groups F,G
  • Class 3

Key Features

Brand LED Lighting Supply
Watts 80
Lumens 11200
Lumens Per Watt 140
Replaces 250 Watt Metal Halide
Voltage 100V-277V
Color Temperature 5000K
CRI 70+
Dimming 1-10V
Beam Angles (Std) 120°
Optics Polycarbonate Lens
Lifespan 50,000 (L70) hours
Mounting Chain-Cable or Recessed or Surface
Frequency (Hz) 50-60Hz
Power Factor >.95
THD < 10%

Durable Construction

IP Rating IP66
IK Rating IK09
Operating Temperature -22°F to 122°F
Certifications UL | Rebate Eligible | NSF Rated
Warranty 5 years

Measurements

Dimensions (in) 49 X 23 X 3.7
Weight (lbs) 88

Notes

 

Additional Resources

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.20

Product Overview

This 80-watt explosion proof 2×4 low profile linear LED light delivers 11,200 lumens at 5000K. It is built for hazardous location lighting, explosion proof lighting, paint booth lighting, and chemical processing facility lighting. The fixture is rated for Class I, Division 2 Groups A, B, C, and D; Class II, Division 1 Groups F and G; and Class III locations. It can replace a 250-watt metal halide fixture where the existing location and classification support this configuration.

Core Performance and Output

The fixture produces 11,200 lumens at 140 lumens per watt. A 120-degree beam angle distributes light broadly through the polycarbonate lens. It operates on 100-277V, 50-60Hz power with a power factor above 0.95 and THD below 10%. The 80-watt output can be excessive where mounting heights are low or where concentrated task lighting is required.

Adjustability and Control Options

This fixture supports 1-10V dimming. Dimming control wiring must be planned with the fixture branch circuit and control system. Chain-cable, recessed, and surface mounting configurations are available. The selected mounting method affects fixture position, service access, and final light distribution.

Longevity and Reliability

The LED system is rated for 50,000 L70 hours. This rating indicates the point at which light output is expected to reach 70 percent of initial output. The fixture operates from -22 degrees F to 122 degrees F. It carries a 5-year warranty.

Build Quality and Physical Characteristics

The low profile linear housing measures 49 x 23 x 3.7 inches and weighs 88 pounds. Its size and weight require mounting support appropriate for the selected installation method. The fixture has an IP66 rating and IK09 impact rating. A polycarbonate lens protects the optical assembly.

Where This Product Fits Best

This fixture fits classified locations requiring a linear, broad-distribution LED fixture with hazardous-location ratings. Its 80-watt output and 2×4 form factor align with installations needing distributed general lighting rather than narrow-beam illumination.
  • hazardous location lighting
  • explosion proof lighting
  • paint booth lighting
  • chemical processing facility lighting
  • oil and gas facility lighting
  • refinery lighting
  • solvent storage area lighting
IP66 and IK09 ratings support installations exposed to dust, water ingress, and physical impact. Final location classification must match the fixture’s listed Class, Division, and Group ratings.

Installation and Long-Term Use

Installers can use chain-cable, recessed, or surface mounting based on the available structure and fixture access requirements. The 88-pound fixture weight must be accounted for when preparing the mounting surface or suspension system. Confirm the 100-277V supply, hazardous-location classification, and required dimming arrangement before installation. Maintain access for future cleaning, inspection, and electrical service.

How This Fixture Is Commonly Used

In hazardous location lighting and explosion proof lighting layouts, the fixture is positioned to provide broad 120-degree distribution across the planned work area. Mounting height is determined by the site layout, light level requirements, and available mounting structure. Paint booth lighting and chemical processing facility lighting layouts commonly use repeated linear fixture rows where broad, consistent distribution is required. Fixture spacing varies with mounting height, target light levels, and the required uniformity across the layout.

Safety, Certifications, and Warranty

UL 844 Hazardous Locations. Class I, Division 2, Groups A, B, C, and D. Class II, Division 1, Groups F and G. Class III. UL listed. NSF rated. Rebate eligible. IP66 rated. IK09 rated. 5-year warranty.

Frequently Asked Questions

Q: What is the light output of this explosion proof fixture? A: The fixture delivers 11,200 lumens using 80 watts. Q: What voltage does this fixture operate on? A: It operates on 100-277V, 50-60Hz power. Q: Is 1-10V dimming available? A: Yes. The fixture supports 1-10V dimming. Q: What mounting methods are available? A: Chain-cable, recessed, and surface mounting are available. Q: What hazardous location classifications are listed? A: The fixture is listed for Class I, Division 2 Groups A, B, C, and D; Class II, Division 1 Groups F and G; and Class III.

Application Questions and Clarification

Q: Can this fixture be used for paint booth lighting? A: Paint booth lighting is a listed application. Confirm that the paint booth classification matches the fixture’s listed Class, Division, and Group ratings. Q: What should be reviewed when planning fixture placement for chemical processing facility lighting? A: Mounting height, target light levels, layout requirements, and the 120-degree beam angle affect fixture placement. A specific spacing value is not established by the supplied product data. Q: Is this fixture appropriate for solvent storage area lighting? A: Solvent storage area lighting is a listed application. The area classification must be verified against the fixture’s Class I, Division 2 Groups A, B, C, and D listing. Web ID: 1931

You may also like