Menu
Search Icon

80 Watt Explosion Proof 2x4 Low Profile Linear LED Light | 11200 Lumens | Class 1 Div 2 | 5000K | 100-277V

SKU: MLLG-E-LED-EXPLP24-80-50-C1D2 | Web ID: 1931
Starting at: $1,245.37
Built to Order 6 Weeks

Out of stock

Get your quote within 1 hour!

80 Watt LED Explosion Proof 2X4 panel - Class 1 Division 2 light replaces fluorescent lighting for hazardous locations. The fixture can work as a surface mount, ceiling mount, and recessed mount. Integrated emergency backup module is optional.

Neil Peterson | CEO and Chief Lighting Specialist

Product Description

UL Listed - Verified for Electrical Safety and PerformanceRebate Eligible - Qualifies for Energy Incentive ProgramsNSF Certified - Sanitary and Food-Safe for Clean EnvironmentsClass 1 Division 2 - UL844 Certified for Explosive Atmospheres5 Year Unlimited Usage Warranty

UL Specs

  • UL 844 Hazardous Locations
  • Class 1, Division 2, Groups A,B,C,D
  • Class 2, Division 1, Groups F,G
  • Class 3

Key Features

  • Watts: 80
  • Lumens: 11200
  • Lumens Per Watt: 140
  • Replaces: 250 Watt Metal Halide
  • Voltage: 100V-277V
  • Color Temperature: 5000K
  • CRI: 70+
  • Dimming: 1-10V
  • Beam Angles (Std): 120°
  • Optics: Polycarbonate Lens
  • Lifespan: 50,000 (L70) hours
  • Mounting: Chain-Cable or Recessed or Surface
  • Frequency (Hz): 50-60Hz
  • Power Factor: >.95
  • THD: < 10%

Durable Construction

  • IP Rating: IP66
  • IK Rating: IK09
  • Operating Temperature: -22°F to 122°F
  • Certifications: UL | Rebate Eligible | NSF Rated
  • Warranty: 5 years

Measurements

  • Dimensions (in): 49 X 23 X 3.7
  • Weight (lbs): 88 lbs

Notes



Download IES Files

Web ID: 1931

Product Overview

This 80 Watt Explosion Proof 2x4 Low Profile Linear LED Light is designed for hazardous location lighting where flammable gases, vapors, or dusts are present. The fixture delivers 11,200 lumens at 5000K, providing a clear, neutral-white output suitable for critical visibility in classified environments. Typical installations include paint booths, chemical processing areas, and industrial spaces requiring Class I, II, or III protection.

The low-profile linear form factor allows for mounting in areas with limited overhead clearance or where a compact footprint is required. This fixture is a direct replacement for legacy 250W metal halide units, supporting mounting heights commonly found in hazardous and process environments.

Core Performance and Output

This fixture outputs 11,200 lumens at 80 watts, achieving 140 lumens per watt. The 120° beam angle provides broad, even coverage for open hazardous areas and work zones. Color temperature is 5000K with a CRI above 70, supporting accurate color rendering for inspection and process tasks.

Electrical performance includes a power factor above 0.95 and THD below 10%, with universal 100-277V input. Dimming is supported via 1-10V controls. At mounting heights below 10 feet, output may be excessive for confined spaces; at heights above 18 feet, uniformity may decrease without additional fixtures or layout adjustments.

Adjustability and Control Options

The fixture supports 1-10V dimming for output adjustment and integration with lighting control systems. This allows for energy management and adaptation to task requirements in hazardous environments. No onboard occupancy or daylight sensors are included; external controls must be specified if needed.

Mounting options include chain-cable, recessed, or surface installation, providing flexibility for different ceiling types and structural conditions. The fixture is not designed for adjustable aiming; it is intended for fixed, direct illumination.

Longevity and Reliability

L70 rated life is 50,000 hours, supporting long-term operation in demanding industrial settings. The fixture is sealed to IP66, preventing ingress of dust and water, and rated IK09 for impact resistance. Operating temperature range is -22°F to 122°F, suitable for most indoor and sheltered outdoor hazardous locations.

All components are selected for durability in classified environments. The fixture is NSF rated for use in areas requiring food safety compliance, and the enclosure resists corrosion and chemical exposure typical in process and paint booth applications.

Build Quality and Physical Characteristics

The fixture measures 49 x 23 x 3.7 inches and weighs 88 lbs. The housing is engineered for hazardous location use, with a polycarbonate lens and robust gasketing. All hardware and seals are designed to maintain integrity in explosive atmospheres and during routine washdown or cleaning.

Surface, chain-cable, and recessed mounting hardware is compatible with standard industrial ceiling structures. The low-profile design minimizes interference with overhead equipment and ductwork. The fixture is not intended for portable or temporary use.

Where This Product Fits Best

This fixture is intended for classified hazardous locations where explosive gases, vapors, or dusts are present, and where a linear, low-profile form factor is required. It is suitable for both new construction and retrofit projects replacing legacy hazardous location luminaires.

  • hazardous location lighting
  • explosion proof lighting
  • paint booth lighting
  • chemical processing facility lighting
  • oil and gas facility lighting
  • refinery lighting
  • wastewater treatment lighting
  • solvent storage area lighting

The fixture is rated for Class I Division 2, Class II Division 1, and Class III environments. It is also suitable for marine and offshore applications where hazardous atmospheres and corrosion resistance are required.

Installation and Long-Term Use

Installation supports chain-cable, recessed, or surface mounting. The fixture?s weight and size require secure attachment to structural supports. All wiring must comply with hazardous location codes and practices, including proper sealing and conduit connections.

Routine maintenance is minimized due to the sealed, solid-state design. Cleaning and inspection should follow facility hazardous area protocols. The fixture is not field-serviceable; replacement is recommended if the enclosure or lens is compromised.

How This Fixture Is Commonly Used

Common mounting heights range from 10 to 18 feet, depending on the area classification and required light levels. Fixtures are typically spaced to provide uniform coverage, with layout patterns adjusted for aisle, booth, or open area configurations.

In paint booths and process areas, linear fixtures are installed parallel to work surfaces or equipment lines. Higher output allows for wider spacing, but may increase glare if installed too close to task areas. Dimming can be used to fine-tune light levels as needed.

Safety, Certifications, and Warranty

This fixture is UL 844 listed for hazardous locations, with Class I Division 2 Groups A, B, C, D; Class II Division 1 Groups F, G; and Class III ratings. It is IP66 and IK09 rated, NSF certified, and suitable for use in food and chemical processing environments.

Warranty is 5 years. All certifications are documented for regulatory compliance and inspection requirements.

Frequently Asked Questions

Q: What hazardous location classifications does this fixture meet?

A: This fixture is UL 844 listed for Class I Division 2 Groups A, B, C, D; Class II Division 1 Groups F, G; and Class III environments.

Q: What are the available mounting options?

A: Chain-cable, recessed, and surface mounting are supported. All mounting hardware must be compatible with hazardous location requirements.

Q: Can this fixture be used in paint booths with washdown requirements?

A: Yes, the fixture is IP66 and NSF rated, supporting use in paint booths and areas requiring routine washdown.

Q: What is the recommended mounting height for optimal performance?

A: Typical mounting heights are 10 to 18 feet. Output may be excessive below 10 feet and uniformity may decrease above 18 feet without additional fixtures.

Q: Is this fixture compatible with lighting controls?

A: 1-10V dimming is supported. External control systems can be integrated as required.

Q: How should fixture spacing be planned in hazardous areas?

A: Spacing depends on mounting height, area size, and required light levels. Wider spacing is possible at higher mounting heights, but glare and uniformity should be evaluated for each application.

Application Questions and Clarification

Q: Is this fixture suitable for marine or offshore hazardous locations?

A: Yes, the fixture is rated for marine environment lighting and offshore rig lighting where hazardous atmospheres are present.

Q: Can this fixture be used in solvent storage or chemical processing areas?

A: Yes, it is suitable for solvent storage area lighting and chemical processing facility lighting with appropriate hazardous location ratings.

Q: Is this fixture appropriate for wastewater treatment plant hazardous zones?

A: Yes, the fixture is commonly installed in wastewater treatment lighting applications with classified hazardous areas.

Q: Does the fixture meet requirements for food processing hazardous locations?

A: The fixture is NSF rated and can be used in food processing areas that require hazardous location compliance.