80 Watt Explosion Proof Linear LED Light | 11,200 Lumens | Class 1 Div 2 | 5000K | 100-277V | 4 Foot
This 80 Watt Explosion Proof Linear LED Light is a strong choice for hazardous locations requiring Class I Division 2, Class II Division 1 and 2, or Class III protection, thanks to its UL 844 listing, robust copper-free aluminum housing, and IP66/IK08 ratings for dust, water, and impact resistance. Its 11,200 lumen output at 5000K with a 120° beam angle provides broad, even illumination suitable for chemical plants, refineries, grain processing, wastewater treatment, and marine environments, including food processing areas due to its NSF rating.
Product Specifications
UL Specs
- UL 844 Hazardous Locations
- Class I, Division 2, Groups A, B, C, D
- Class II, Division 1, Groups E, F, G
- Class II, Division 2, Groups F, G
- Class III
- UL 1598 Suitable for Wet Locations
- UL 1598A Marine Outside Type
- ABS
Key Features
| Brand | LED Lighting Supply |
| Watts | 80 |
| Lumens | 11200 |
| Lumens Per Watt | 140 |
| Replaces | 250 Watt Metal Halide |
| Voltage | 100V-277V |
| Color Temperature | 5000K |
| CRI | 70+ |
| Dimming | 1-10V |
| Beam Angles (Std) | 120° |
| Optics | Polycarbonate Lens |
| Lifespan | 50,000 (L70) hours |
| Mounting | Yoke or 3/4 in NPT Pendant |
| Fixture Color | Gray |
| Frequency (Hz) | 50-60Hz |
| Power Factor | >.95 |
| THD | < 10% |
Durable Construction
| Housing | Copper Free Aluminum |
| IP Rating | IP66 |
| IK Rating | IK08 |
| Operating Temperature | -22°F to 122°F |
| Certifications | ETL | Rebate Eligible | NSF Rated |
| Warranty | 5 years |
Measurements
| Dimensions (in) | 47 X 4.7 X 9.5 |
| Weight (lbs) | 15 |
Download IES Files
Product Lighting Layout Estimator
Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.
Project Inputs
Estimated Results
Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.
Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.
Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.
Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.
This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.
Product Overview
This 80-watt explosion proof linear LED light delivers 11,200 lumens at 5000K through a 4-foot sealed fixture body. It is built for hazardous location lighting where a linear fixture, wet-location construction, and classified-location ratings are required.
The fixture operates on 100-277V and replaces 250-watt metal halide fixtures. Its 120-degree distribution supports broad area coverage from a linear mounting position.
Core Performance and Output
The fixture produces 11,200 lumens at 140 lumens per watt. The 5000K color temperature and 70+ CRI provide a neutral white output for hazardous location lighting, paint booth lighting, and chemical processing facility lighting.
A standard 120-degree beam angle distributes light broadly through the polycarbonate lens. At lower mounting heights, 11,200 lumens can create excessive brightness if fixture placement is not coordinated with the work area.
Electrical operation is 100-277V, 50-60Hz, with a power factor above 0.95 and THD below 10%.
Adjustability and Control Options
This fixture supports 1-10V dimming. Dimming control wiring and control compatibility must be confirmed as part of the installation design.
Mounting is available by yoke or 3/4-inch NPT pendant connection. The yoke supports directional fixture positioning, while the pendant connection provides a fixed suspended installation method.
Longevity and Reliability
Rated life is 50,000 hours at L70. The fixture is rated for operation from -22 degrees F to 122 degrees F.
The sealed IP66 enclosure and IK08 impact rating support use in demanding classified and wet-location conditions. Long-term performance depends on maintaining the enclosure, lens, mounting connection, and electrical seals.
Build Quality and Physical Characteristics
The fixture uses a copper-free aluminum housing with a gray finish and polycarbonate lens. It measures 47 x 4.7 x 9.5 inches and weighs 15 pounds.
The linear body is intended for yoke or 3/4-inch NPT pendant mounting. Mounting structure and connection components must support the fixture weight and installation method.
Where This Product Fits Best
This fixture fits classified, wet, marine, and industrial environments where explosion proof lighting is required and a 4-foot linear fixture form is appropriate.
- hazardous location lighting
- paint booth lighting
- chemical processing facility lighting
- oil and gas facility lighting
- refinery lighting
- marine environment lighting
- wastewater treatment lighting
Its Class I, II, and III ratings, IP66 rating, and marine outside type listing align with these environments. Final application fit depends on the required location classification, group, division, mounting method, and layout.
Installation and Long-Term Use
Install the fixture using the yoke or 3/4-inch NPT pendant mounting option. Verify the location classification and electrical installation requirements before mounting the fixture.
For long-term use, inspect the housing, lens, mounting hardware, wiring connections, and enclosure seals during scheduled maintenance. Fixture access should be considered when locating units in hazardous location lighting and refinery lighting layouts.
How This Fixture Is Commonly Used
In hazardous location lighting and paint booth lighting layouts, the fixture is mounted to place its broad 120-degree distribution across the required work area. Mounting height is evaluated with the target light level, obstructions, and available mounting structure.
In chemical processing facility lighting, oil and gas facility lighting, and wastewater treatment lighting, linear rows or individually positioned fixtures are used according to the layout and classified-area boundaries. Spacing varies with mounting height, target light levels, and the required distribution pattern.
Safety, Certifications, and Warranty
UL 844 Hazardous Locations. Class I, Division 2, Groups A, B, C, D. Class II, Division 1, Groups E, F, G. Class II, Division 2, Groups F, G. Class III.
UL 1598 Suitable for Wet Locations. UL 1598A Marine Outside Type. ABS. ETL. NSF Rated. IP66. IK08.
The fixture includes a 5-year warranty.
Frequently Asked Questions
Q: What is the light output of this explosion proof linear LED fixture?
A: The fixture produces 11,200 lumens while using 80 watts.
Q: What voltage does this fixture operate on?
A: The fixture operates on 100-277V at 50-60Hz.
Q: Can this fixture be dimmed?
A: Yes. It supports 1-10V dimming.
Q: What mounting options are available?
A: The fixture is available with yoke mounting or 3/4-inch NPT pendant mounting.
Q: How should fixture spacing be planned?
A: Mounting height, target light levels, obstructions, and layout requirements affect spacing. A specific spacing value is not established by the supplied product data.
Application Questions and Clarification
Q: Is this fixture suitable for hazardous location lighting?
A: The fixture is rated UL 844 for Class I, Division 2, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class II, Division 2, Groups F, G; and Class III locations.
Q: What should be confirmed for paint booth lighting installations?
A: Confirm the required location classification, electrical installation requirements, mounting method, and fixture layout before installation.
Q: Can this fixture be used for marine environment lighting?
A: The fixture is UL 1598A Marine Outside Type listed, ABS rated, and IP66 rated.
Web ID: 2668