70 Watt Round Explosion Proof LED Light | 9800 Lumens | Class 1 Div 1 | 5000K | 100-277V

SKU: LLS-EXPLC-70-5-C1D1 Web ID: 2314
Starting at: $681.78

 

Availability: 64 In Stock Ships 3-5 Days

This 70 watt round explosion proof LED fixture is a strong choice for hazardous locations due to its certified suitability for Class 1 Division 1 and Division 2, Groups B, C, D, as well as Class 2 and 3 environments, making it reliable in areas with explosive gases, vapors, or dusts. Its 9800 lumen output at 5000K ensures clear visibility for industrial tasks, while the IP66 and IK10 ratings provide robust protection against water, dust, and impacts. With flexible mounting options and a 150,000 hour L70 lifespan, it is ideal for chemical plants, refineries, paint shops, grain processing, and marine facilities.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

64 in stock (can be backordered)

Product Options

Product total

Options total

Sub-Total

Product Specifications

UL Listed - Verified for Electrical Safety and PerformanceCSA Listed - Verified for Electrical Safety and PerformanceClass 1 Division 1 - UL844 Certified for Hazardous Locations5 Year Unlimited Usage Warranty

UL Specs

  • UL 844 Hazardous Locations
  • Class 1 Division 1, Group B, C, D
  • Class 1 Division 2, Group B, C, D
  • Class 2, Division 1, Groups E, F, G
  • Class 2, Division 2, Groups F, G
  • Class 3
  • UL 1598 Suitable for Wet Locations
  • UL1598A Marine Outside Type
  • CSA / ATEX / IECEX

Key Features

Brand LED Lighting Supply
Watts 70
Lumens 9800
Lumens Per Watt 140
Replaces 250 Watt Metal Halide
Voltage 100V-277V
Color Temperature 5000K
CRI 70+
Dimming 1-10V
Beam Angles (Std) 120°
Optics Tempered Glass Lens
Lifespan 150,000 (L70) hours
Mounting Yoke or 3/4 in NPT Pendant
Mounting (Opt) Surface or Wall
Fixture Color Gray
Frequency (Hz) 50/60
Power Factor >.90
THD < 10%

Durable Construction

Housing Powder Coated Aluminum
IP Rating IP66
IK Rating IK10
Surge Protection 10kV
Operating Temperature -22°F to 122°F
Certifications UL
Warranty 5 years

Measurements

Dimensions (in) 13.7 x 11.2
Weight (lbs) 20
Cord Length No Cord

 

Download IES Files

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.20

Product Overview

This 70-watt round explosion proof LED light delivers 9,800 lumens at 5000K for hazardous location lighting. It is built for Class I, II, and III classified areas where fixture construction, sealing, and mounting method must match site conditions. The fixture operates on 100-277V and can replace a 250-watt metal halide fixture. Yoke and 3/4 in NPT pendant mounting support common hazardous-area installation layouts.

Core Performance and Output

The fixture produces 9,800 lumens at 140 lumens per watt. Its 120-degree beam distribution provides broad coverage from a round fixture form factor. It operates at 100-277V, 50/60Hz, with a power factor above 0.90 and THD below 10%. The fixture supports 1-10V dimming. The 9,800-lumen output can be excessive at low mounting heights. Higher mounting positions require layout review to maintain light levels and uniformity.

Adjustability and Control Options

This fixture supports 1-10V dimming. Control wiring and compatibility must be verified against the hazardous-location installation requirements. Standard optics use a tempered glass lens with a 120-degree beam angle. The fixture is available with yoke or 3/4 in NPT pendant mounting, with surface and wall mounting options.

Longevity and Reliability

The rated lifespan is 150,000 hours L70. The fixture includes 10kV surge protection for electrical transient resistance. Its operating temperature range is -22F to 122F. Long-term performance depends on maintaining sealed entries, approved mounting methods, and correct electrical connections.

Build Quality and Physical Characteristics

The housing is powder-coated aluminum with a gray finish. The tempered glass lens protects the optical assembly. This fixture is rated IP66 and IK10. It measures 13.7 by 11.2 inches and weighs 20 pounds. No cord is included. The installer must provide the appropriate wiring method for the selected mounting configuration.

Where This Product Fits Best

This fixture fits classified industrial and marine environments requiring explosion proof lighting with broad distribution and wet-location construction.
  • hazardous location lighting
  • explosion proof lighting
  • chemical processing facility lighting
  • oil and gas facility lighting
  • refinery lighting
  • marine environment lighting
  • offshore rig lighting
IP66, IK10, UL 844, UL 1598 wet-location suitability, and UL1598A Marine Outside Type support use in demanding exposed and classified conditions. Final application fit depends on the installed area’s classification and mounting arrangement.

Installation and Long-Term Use

Yoke mounting suits installations requiring directional aiming, while the 3/4 in NPT pendant connection supports suspended fixture layouts. Surface and wall mounting are optional configurations. The 20-pound fixture requires a mounting structure and connection method appropriate for the installed assembly. All field wiring and sealing details must be completed for the applicable classified location. For long-term use, inspect the glass lens, housing, mounting hardware, and cable entries during scheduled maintenance. Replace damaged components before returning the fixture to service.

How This Fixture Is Commonly Used

In hazardous location lighting, explosion proof lighting, and chemical processing facility lighting, this fixture is positioned to provide broad downward coverage from its 120-degree beam pattern. Mounting height is determined by the area’s layout, required light levels, and obstruction conditions. Oil and gas facility lighting, refinery lighting, marine environment lighting, and offshore rig lighting often use the pendant or yoke mounting configuration based on available structure and aiming requirements. Fixture placement follows the classified-area boundaries and approved installation method. Higher output can reduce fixture count in a layout, but it can also require closer review of glare and uniformity. Spacing varies with mounting height, target illumination, and the selected mounting orientation.

Safety, Certifications, and Warranty

UL 844 Hazardous Locations. Class I Division 1 Groups B, C, D. Class I Division 2 Groups B, C, D. Class II Division 1 Groups E, F, G. Class II Division 2 Groups F, G. Class III. UL 1598 Suitable for Wet Locations. UL1598A Marine Outside Type. CSA. ATEX. IECEx. IP66. IK10. This fixture includes a 5-year warranty.

Frequently Asked Questions

Q: What is the light output of this explosion proof fixture? A: The fixture delivers 9,800 lumens while operating at 70 watts. Q: What voltage does this fixture use? A: The fixture operates on 100-277V, 50/60Hz. Q: Which mounting configurations are available? A: Standard mounting is yoke or 3/4 in NPT pendant. Surface and wall mounting are optional configurations. Q: What should be considered when planning fixture placement? A: The 120-degree beam angle, 9,800-lumen output, mounting height, target light levels, and layout requirements affect fixture placement. A specific spacing value is not established by the supplied product data.

Application Questions and Clarification

Q: Can this fixture be used for hazardous location lighting? A: The fixture is rated UL 844 Hazardous Locations and is classified for Class I Division 1 Groups B, C, D; Class I Division 2 Groups B, C, D; Class II Division 1 Groups E, F, G; Class II Division 2 Groups F, G; and Class III. Q: What should be verified for chemical processing facility lighting? A: Verify the area’s classification, available voltage, mounting arrangement, and required fixture placement before installation. Q: Is this fixture configured for marine environment lighting? A: The fixture is rated UL1598A Marine Outside Type and IP66. Web ID: 2314

You may also like