60 Watt Explosion Proof 2×2 Low Profile Linear LED Light | 8400 Lumens | Class 1 Div 2 | 5000K | 100-277V

SKU: MLLG-E-LED-EXPLP22-60-50-C1D2 Web ID: 1936
Starting at: $1,085.40

 

Built to Order 8-10 Weeks

The 60 Watt Explosion Proof 2×2 Low Profile Linear LED Light is ideal for hazardous locations, offering 8400 lumens at 5000K with a robust IP66 and IK09 rating. Its UL 844 and Class I/II/III certifications ensure safety in volatile environments like paint booths and industrial facilities. With versatile mounting options and a lifespan of 50,000 hours, it efficiently replaces 250W metal halides, providing reliable, energy-efficient lighting in challenging conditions.

Neil Peterson | CEO and Chief Lighting Specialist

Product Specifications

UL Listed - Verified for Electrical Safety and PerformanceRebate Eligible - Qualifies for Energy Incentive ProgramsNSF Certified - Sanitary and Food-Safe for Clean EnvironmentsClass 1 Division 2 - UL844 Certified for Explosive Atmospheres5 Year Unlimited Usage Warranty

UL Specs

  • UL 844 Hazardous Locations
  • Class 1, Division 2, Groups A,B,C,D
  • Class 2, Division 1, Groups F,G
  • Class 3

Key Features

Brand LED Lighting Supply
Watts 60
Lumens 8400
Lumens Per Watt 140
Replaces 250 Watt Metal Halide
Voltage 100V-277V
Color Temperature 5000K
CRI 70+
Dimming 1-10V
Beam Angles (Std) 120°
Optics Polycarbonate Lens
Lifespan 50,000 (L70) hours
Mounting Chain-Cable or Recessed or Surface
Frequency (Hz) 50-60Hz
Power Factor >.95
THD < 10%

Durable Construction

IP Rating IP66
IK Rating IK09
Operating Temperature -22°F to 122°F
Certifications UL | Rebate Eligible | NSF Rated
Warranty 5 years

Measurements

Dimensions (in) 25.2 L X 23.8 W X 3.7 H
Weight (lbs) 46.3

 

Additional Resources

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.20

Product Overview

This 60 watt explosion proof 2×2 low profile linear LED light delivers 8400 lumens at 5000K. It is built for hazardous location lighting where a linear fixture form factor, low profile housing, and multiple mounting methods are required. The fixture operates on 100-277V and replaces 250 watt metal halide fixtures. Chain-cable, recessed, and surface mounting support different installation layouts within classified areas.

Core Performance and Output

The fixture produces 8400 lumens at 140 lumens per watt. Its 120 degree beam distribution provides broad light coverage from the polycarbonate lens. Electrical performance includes 100-277V operation, 50-60Hz frequency, power factor above 0.95, and THD below 10%. At lower mounting heights, 8400 lumens may create more light than needed unless fixture placement and dimming are considered. The 120 degree distribution supports broad layouts, but mounting height and target light levels affect uniformity. Higher mounting locations require project-specific layout review to control light levels between fixtures.

Adjustability and Control Options

This fixture includes 1-10V dimming. Dimming can be used where adjustable light output is needed after installation. The fixture is available with chain-cable, recessed, or surface mounting. The selected mounting method affects fixture position, ceiling clearance, and access for future maintenance.

Longevity and Reliability

Rated life is 50,000 hours at L70. The fixture is rated for operation from -22F to 122F. The IP66 rating and IK09 impact rating are part of the fixture construction. Long-term performance still depends on maintaining the mounting system, wiring connections, lens condition, and surrounding installation conditions.

Build Quality and Physical Characteristics

The low profile linear housing measures 25.2 inches long by 23.8 inches wide by 3.7 inches high. Fixture weight is 46.3 pounds. A polycarbonate lens provides the optical cover. The fixture uses a 5000K color temperature and a CRI of 70 or higher.

Where This Product Fits Best

This fixture fits classified and hazardous operating areas where explosion proof construction, broad light distribution, and linear mounting options are needed. Its 60 watt output is suited to localized and general lighting layouts based on project light-level requirements.
  • hazardous location lighting
  • explosion proof lighting
  • paint booth lighting
  • chemical processing facility lighting
  • oil and gas facility lighting
  • refinery lighting
UL 844 hazardous locations, Class I Division 2 Groups A, B, C, and D, Class II Division 1 Groups F and G, and Class III ratings apply. The fixture is also IP66, IK09, and NSF rated.

Installation and Long-Term Use

Chain-cable, recessed, and surface mounting are available for this fixture. The 46.3 pound fixture weight and 25.2 by 23.8 inch footprint should be accounted for when preparing the mounting location. Installers should confirm supply voltage, mounting method, fixture orientation, and dimming requirements before installation. The recessed option requires a prepared opening that accommodates the fixture dimensions.

How This Fixture Is Commonly Used

In hazardous location lighting, paint booth lighting, and chemical processing facility lighting, this fixture is positioned according to the mounting height, target light level, and equipment or process layout. The selected mounting method determines whether the fixture is suspended, recessed, or surface mounted. Layouts use the 120 degree beam pattern to create broad coverage across the planned area. Higher output can reduce fixture count, but spacing and mounting height still determine uniformity and glare control.

Safety, Certifications, and Warranty

UL 844 Hazardous Locations. Class I Division 2 Groups A, B, C, and D. Class II Division 1 Groups F and G. Class III. The fixture is UL listed, rebate eligible, NSF rated, IP66 rated, and IK09 rated. Warranty coverage is 5 years.

Frequently Asked Questions

Q: What light output does this explosion proof fixture provide? A: The fixture delivers 8400 lumens while operating at 60 watts. Q: What voltage does this fixture use? A: It operates on 100-277V at 50-60Hz. Q: Can this fixture be dimmed? A: Yes. It includes 1-10V dimming. Q: What fixture information should be considered during layout planning? A: Layout planning should account for the 8400 lumen output, 120 degree beam angle, mounting method, mounting height, and target light levels.

Application Questions and Clarification

Q: Is this fixture intended for hazardous location lighting? A: Yes. It is listed for hazardous location lighting and has UL 844 hazardous locations ratings. Q: Which mounting methods are available for paint booth lighting layouts? A: Chain-cable, recessed, and surface mounting are available. Web ID: 1936

You may also like