60 Watt Round Explosion Proof LED Light | 8400 Lumens | Class 1 Div 2 | 5000K | 100V-277V | NSF Rated
Product Specifications
UL Specs
- UL 844 Hazardous Locations
- Class I, Division 2, Groups A, B, C, D
- Class II, Division 1, Groups E, F, G
- Class II, Division 2, Groups F, G
- Class III
- UL 1598 Suitable for Wet Locations
- UL 1598A Marine Outside Type
- ABS
- NSF
Key Features
| Brand | LED Lighting Supply |
| Watts | 60 |
| Lumens | 8400 |
| Lumens Per Watt | 140 |
| Replaces | 250 Watt Metal Halide |
| Voltage | 100V-277V |
| Color Temperature | 5000K |
| CRI | 80+ |
| Dimming | 1-10V |
| Beam Angles (Std) | 120° |
| Optics | Polycarbonate Lens |
| Lifespan | 50,000 (L70) hours |
| Mounting | 3/4 in NPT Pendant |
| Frequency (Hz) | 50-60Hz |
| Power Factor | >.95 |
Durable Construction
| Housing | Copper Free Aluminum |
| IP Rating | IP66 |
| IK Rating | IK10 |
| Surge Protection | 10kV |
| Operating Temperature | -40°F to 140°F |
| Certifications | ETL | Rebate Eligible | NSF Rated |
| Warranty | 5 years |
Features/Accessories
- NSF Rated Food Grade
Download IES Files
Product Lighting Layout Estimator
Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.
Project Inputs
Estimated Results
Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.
Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.
Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.
Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.
This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.
Product Overview
This 60-watt round explosion proof LED light delivers 8,400 lumens at 5000K for hazardous location lighting. It uses a 3/4 in NPT pendant mount and operates on 100V-277V power.
The fixture is configured for locations requiring Class I, II, or III hazardous-location ratings. Its 120 degree distribution supports broad downward illumination from a pendant-mounted position.
Core Performance and Output
The fixture produces 8,400 lumens at 140 lumens per watt. It replaces a 250-watt metal halide fixture and provides 80+ CRI light at 5000K.
A standard 120 degree beam angle distributes light across a broad area below the fixture. At lower mounting heights, the 8,400-lumen output can create higher light levels directly beneath the fixture.
The driver operates at 100V-277V, 50-60Hz, with a power factor above 0.95. It includes 1-10V dimming capability.
Adjustability and Control Options
This fixture supports 1-10V dimming. Dimming wiring and control compatibility should be confirmed during project layout and electrical design.
The fixture has a fixed 120 degree beam distribution. The polycarbonate lens is part of the standard optical configuration.
Longevity and Reliability
Rated life is 50,000 hours at L70. The fixture includes 10kV surge protection.
The operating temperature range is -40 degrees F to 140 degrees F. A five-year warranty is included.
Build Quality and Physical Characteristics
The housing is copper-free aluminum with an IK10 impact rating. The fixture carries an IP66 rating.
A polycarbonate lens protects the optical assembly. The 3/4 in NPT pendant mount provides a threaded mounting connection for the fixture.
Where This Product Fits Best
This fixture fits hazardous and classified environments where its Class I, II, and III ratings align with site requirements. The NSF rating and wet-location suitability support installations with demanding environmental conditions.
- hazardous location lighting
- explosion proof lighting
- chemical processing facility lighting
- paint booth lighting
- oil and gas facility lighting
- marine environment lighting
Its IP66 rating, IK10 impact rating, copper-free aluminum housing, and -40 degrees F to 140 degrees F operating range address wet, exposed, and physically demanding conditions within the listed applications.
Installation and Long-Term Use
The fixture mounts through a 3/4 in NPT pendant connection. The mounting assembly, support structure, wiring method, and hazardous-location requirements must match the installation conditions.
Mounting height affects the distribution pattern and light level at the work plane. The fixed 120 degree optic should be reviewed against the planned fixture layout before installation.
How This Fixture Is Commonly Used
In hazardous location lighting, paint booth lighting, and chemical processing facility lighting, fixtures are typically arranged around the mounting height, required light level, and available pendant locations. The broad 120 degree optic is intended for downward area coverage.
For oil and gas facility lighting and marine environment lighting, the installation layout must account for fixture position and environmental exposure. Higher output can reduce fixture count, but layout requirements still control light uniformity.
Safety, Certifications, and Warranty
UL 844 Hazardous Locations. Class I, Division 2, Groups A, B, C, D. Class II, Division 1, Groups E, F, G. Class II, Division 2, Groups F, G. Class III.
UL 1598 Suitable for Wet Locations. UL 1598A Marine Outside Type. ABS. NSF. ETL. Rebate Eligible. Five-year warranty.
Frequently Asked Questions
Q: What light output does this explosion proof fixture provide?
A: The fixture delivers 8,400 lumens while consuming 60 watts.
Q: What voltage does this fixture operate on?
A: The fixture operates on 100V-277V, 50-60Hz power.
Q: Does this fixture support dimming?
A: Yes. It supports 1-10V dimming.
Q: What mounting connection does this fixture use?
A: The fixture uses a 3/4 in NPT pendant mount.
Q: What is the standard beam angle?
A: The standard beam angle is 120 degrees.
Application Questions and Clarification
Q: Can this fixture be considered for hazardous location lighting?
A: Yes. The fixture is rated UL 844 Hazardous Locations and is listed for Class I, Division 2; Class II, Division 1 and Division 2; and Class III locations.
Q: What should be reviewed when planning fixture placement?
A: Mounting height, target light levels, pendant mounting locations, and the fixed 120 degree beam distribution affect fixture placement. Specific spacing values are not established by the supplied product data.
Q: Can this fixture be used in marine environment lighting?
A: The fixture is UL 1598A Marine Outside Type, ABS rated, and IP66 rated. Final application fit depends on the site conditions and applicable classification requirements.
Web ID: 2490