Skip to content

60 Watt Round Explosion Proof LED Light | 8400 Lumens | Class 1 Div 2 | 5000K | 100V-277V

SKU: MLLG-E-LED-EXPLB-60-50-[V]-C1D2 Web ID: 1609
Starting at: $560.00
100V-277V:237 In StockShips 3-5 Days
277V-480V:Built to Order 6 Weeks
This 60 watt round explosion proof LED fixture is a strong choice for hazardous industrial environments due to its certified suitability for Class I Division 2, Class II Division 1 and 2, and Class III locations, along with IP66 and IK10 ratings for water, dust, and impact resistance. Its 8400 lumen output at 140 lumens per watt efficiently replaces 250 watt metal halide fixtures, reducing energy use and maintenance with a 50,000 hour L70 lifespan. Flexible mounting, dimming, and beam angle options make it practical for chemical plants, refineries, paint shops, and marine facilities where safety and reliability are critical.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

    Product total

    Options total

    Sub-Total

    Product Specifications

    ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsClass 1 Division 2 - UL844 Certified for Explosive Atmospheres5 Year Unlimited Usage Warranty

    UL Specs

    • UL 844 Hazardous Locations
    • Class I, Division 2, Groups A, B, C, D
    • Class II, Division 1, Groups E, F, G
    • Class II, Division 2, Groups F, G
    • Class III
    • UL 1598 Suitable for Wet Locations
    • UL 1598A Marine Outside Type
    • ABS

    ATEX Marking

    • II 3 G Ex ec IIC T6...T3 Gc
    • II 2 D Ex tb IIIC T85°C...T103°C Db

    IECEx Marking

    • Ex ec IIC T6...T3 Gc
    • Ex tb IIIC T85°C...T100°C Db

    Key Features

    BrandLED Lighting Supply
    Watts60
    Lumens8400
    Lumens Per Watt140
    Replaces250 Watt Metal Halide
    Voltage100V-277V or 277V-480V
    Color Temperature5000K
    CRI70+
    Dimming1-10V
    Beam Angles (Std)120°
    Beam Angles (Opt)40° or 60° or 90°
    OpticsTempered Glass Lens
    Lifespan50,000 (L70) hours
    MountingYoke or 3/4 in NPT Pendant
    Fixture ColorGray
    Frequency (Hz)50-60Hz
    Power Factor>.95
    THD< 10%

    Durable Construction

    HousingCopper Free Aluminum
    IP RatingIP66
    IK RatingIK10
    Surge Protection10kV
    Operating Temperature-40°F to 140°F
    CertificationsETL | Rebate Eligible
    Warranty5 years

    Measurements

    Dimensions (in)7.09 x 9.09
    Weight (lbs)8 lbs

    Product SKU Variations

    • SKU: MLLG-E-LED-EXPLB-60-50-C1D2
    • SKU: MLLG-E-LED-EXPLB-60-50-C1D2-HV

    Product Lighting Layout Estimator

    Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

    Project Inputs

    Loading fixture information...

    Estimated Results

    Fixtures --
    Layout --
    Estimated Avg FC --
    Approx. Spacing --
    Fixture Offset --
    Calculation Method: --
    Top-Down Fixture Layout Fixture positions and estimated floor light levels
    Lower estimated FC Near target Higher estimated FC

    Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

    Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

    Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

    Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

    Need Verified Light Levels?

    This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

    Estimator Version 2.9.21

    Product Overview

    This 60W round LED explosion proof light delivers 8,400 lumens at 5000K for hazardous-location lighting. It is available in 100V-277V or 277V-480V configurations and provides a 120-degree standard beam angle.

    The fixture is rated for Class I, Division 2 Groups A, B, C, and D; Class II Division 1 Groups E, F, and G; Class II Division 2 Groups F and G; and Class III locations. It can replace a 250W metal halide fixture.

    Core Performance and Output

    The 60W LED system produces 140 lumens per watt with a CRI of 70+ and a 5000K color temperature. Optional 40-degree, 60-degree, and 90-degree beam angles are available where a narrower distribution is needed.

    1-10V dimming is supported. The driver operates at 50-60Hz with a power factor greater than 0.95 and THD below 10%.

    Longevity and Reliability

    The fixture has a 50,000-hour L70 rated life and operates in ambient temperatures from -40 degrees F to 140 degrees F. A 10kV surge protection rating supports use on electrical systems exposed to transient voltage events.

    Build Quality and Physical Characteristics

    The gray copper-free aluminum housing uses a tempered glass lens. Its IP66 rating and IK10 impact rating support use in wet and demanding industrial environments.

    The round fixture measures 7.09 x 9.09 inches and weighs 8 lb. Mounting options include a yoke mount or 3/4 in NPT pendant mount.

    Where This Product Fits Best

    This explosion proof fixture is suited to hazardous and industrial locations within its stated hazardous-location classifications, including wet and marine outside environments.

    • hazardous location lighting
    • explosion proof lighting
    • paint booth lighting
    • chemical processing facility lighting
    • oil and gas facility lighting
    • refinery lighting
    • marine environment lighting
    • offshore rig lighting

    Safety, Certifications, and Warranty

    This fixture is UL 844 hazardous location certified, UL 1598 suitable for wet locations, UL 1598A Marine Outside Type, ABS, ETL listed, ATEX marked, and IECEx marked. It carries a 5-year warranty.

    Frequently Asked Questions

    Q: What hazardous-location classifications does this 60W explosion proof light carry?

    A: This 60W explosion proof light is rated for Class I, Division 2 Groups A, B, C, and D; Class II Division 1 Groups E, F, and G; Class II Division 2 Groups F and G; and Class III locations.

    Q: What mounting options are available for this round explosion proof light?

    A: This round explosion proof light is available with a yoke mount or a 3/4 in NPT pendant mount.

    Q: Is this explosion proof light available with different beam angles?

    A: This explosion proof light has a 120-degree standard beam angle and optional 40-degree, 60-degree, and 90-degree beam angles.