40 Watt Explosion Proof Vapor Tight LED Light | 5600 Lumens | Class 1 Div 2 | 5000K | 100-277V | 2 Foot
This hazardous location LED fixture is a strong choice for environments where safety, durability, and efficiency are critical. With 5600 lumens at 40 watts, it efficiently replaces 150W metal halide units while providing broad, even illumination through its 120 degree beam angle. The stainless steel housing, polycarbonate lens, IP66, and IK10 ratings ensure reliable operation in wet, dusty, corrosive, or high-impact areas. UL 844, UL 1598, UL 1598A, ABS, and ETL certifications support use in hazardous, marine, and industrial settings such as chemical plants, refineries, offshore platforms, and cold storage.
137 in stock
Product Specifications
UL Specs
- UL 844 Hazardous Locations
- Class I, Division 2, Groups A, B, C, D
- Class II, Division 1, Groups E, F, G
- Class II, Division 2, Groups F, G
- Class III
- UL 1598 Suitable for Wet Locations
- UL 1598A Marine Outside Type
- ABS
Key Features
| Brand | LED Lighting Supply |
| Watts | 40 |
| Lumens | 5600 |
| Lumens Per Watt | 140 |
| Replaces | 150 Watt Metal Halide |
| Voltage | 100V-277V |
| Color Temperature | 5000K |
| CRI | 80+ |
| Dimming | 1-10V |
| Beam Angles (Std) | 120° |
| Optics | Polycarbonate Lens |
| Lifespan | 50,000 (L70) hours |
| Mounting | Surface |
| Frequency (Hz) | 50-60Hz |
| Power Factor | >.95 |
| THD | < 10% |
Durable Construction
| Housing | Stainless Steel |
| IP Rating | IP66 |
| IK Rating | IK10 |
| Operating Temperature | -40°F to 122°F |
| Certifications | ETL | Rebate Eligible |
| Warranty | 5 years |
Measurements
| Dimensions (in) | 28 X 8.6 X 5.3 |
| Weight (lbs) | 11 |
Download IES Files
Product Lighting Layout Estimator
Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.
Project Inputs
Estimated Results
Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.
Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.
Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.
Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.
This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.
Product Overview
This 40-watt explosion proof vapor tight LED light is a 2-foot linear fixture for hazardous location lighting where a sealed, impact-resistant housing is required. It produces 5600 lumens at 5000K through a polycarbonate lens.
The fixture is configured for Class I, II, and III hazardous locations and supports 100-277V electrical systems. Its 150-watt metal halide replacement rating makes it suitable for lower-output hazardous location retrofit work where existing fixture locations and surface mounting points are retained.
Core Performance and Output
This fixture delivers 5600 lumens at 140 lumens per watt. The standard 120-degree distribution provides broad light coverage from the linear housing, while the 80+ CRI supports general visibility in hazardous work areas.
Input voltage is 100-277V at 50-60Hz. Power factor is greater than 0.95 and total harmonic distortion is below 10%.
The 5600-lumen output can be excessive where mounting height is low or where fixtures are closely spaced. Higher mounting locations and wider layouts require review of target light levels and uniformity because the fixture has a fixed 120-degree beam distribution.
Adjustability and Control Options
This fixture supports 1-10V dimming. Dimming wiring and control equipment must be compatible with the fixture’s 1-10V input.
The standard optical system uses a polycarbonate lens with a 120-degree beam angle. No alternate beam distribution or field-adjustable output is specified.
Longevity and Reliability
The LED system is rated for 50,000 L70 hours. L70 indicates the point at which light output is rated at 70 percent of initial output.
The fixture operates from -40 degrees F to 122 degrees F. This operating range supports installations exposed to low-temperature and elevated-temperature conditions within the stated limits.
Build Quality and Physical Characteristics
The housing is stainless steel and the lens is polycarbonate. The fixture is rated IP66 and IK10.
Overall dimensions are 28 x 8.6 x 5.3 inches, and fixture weight is 11 pounds. It is designed for surface mounting.
Where This Product Fits Best
This fixture fits hazardous industrial and marine-related locations requiring Class I, II, or III hazardous location classifications, wet-location suitability, and a surface-mounted linear form factor.
- hazardous location lighting
- explosion proof lighting
- oil and gas facility lighting
- chemical processing facility lighting
- refinery lighting
- marine environment lighting
- offshore rig lighting
Its IP66 rating, stainless steel housing, polycarbonate lens, and UL 1598A Marine Outside Type listing support use in wet and marine conditions covered by the listed applications.
Installation and Long-Term Use
Surface mounting requires a secure mounting location capable of supporting the 11-pound fixture. Confirm mounting surface condition, wiring entry arrangement, and hazardous-location installation requirements before installation.
The 100-277V input range allows use across common commercial and industrial voltage systems within that range. Connect 1-10V control wiring only when dimming is part of the installation.
Long-term maintenance should include inspection of the stainless steel housing, polycarbonate lens, mounting condition, and wiring integrity. Maintain the enclosure condition required for the installed hazardous location classification.
How This Fixture Is Commonly Used
In hazardous location lighting and explosion proof lighting layouts, the fixture is surface mounted along work areas, process areas, access routes, and equipment zones covered by the project lighting plan. Mounting height is determined by the site layout, target light levels, and required equipment clearance.
Oil and gas facility lighting, refinery lighting, and chemical processing facility lighting installations commonly use repeated linear fixture rows where the 120-degree distribution can overlap between adjacent fixtures. Fixture spacing varies with mounting height, existing mounting locations, and required light levels.
For marine environment lighting and offshore rig lighting, the stainless steel housing and IP66 enclosure support exposed conditions within the fixture’s stated operating range. Higher output can reduce fixture count, but closer evaluation of glare and uniformity is needed in tighter layouts.
Safety, Certifications, and Warranty
UL 844 Hazardous Locations. Class I, Division 2, Groups A, B, C, D. Class II, Division 1, Groups E, F, G. Class II, Division 2, Groups F, G. Class III.
UL 1598 Suitable for Wet Locations. UL 1598A Marine Outside Type. ABS. ETL. Rebate Eligible.
The fixture includes a 5-year warranty.
Frequently Asked Questions
Q: What light output does this explosion proof fixture provide?
A: This fixture produces 5600 lumens at 40 watts, delivering 140 lumens per watt.
Q: What voltage does this fixture operate on?
A: The fixture operates on 100-277V at 50-60Hz.
Q: Is dimming available?
A: Yes. The fixture supports 1-10V dimming.
Q: What mounting method is specified?
A: The fixture is specified for surface mounting.
Q: What should be considered when planning fixture placement?
A: Mounting height, target light levels, existing mounting locations, and layout requirements affect fixture placement. A specific spacing value is not established by the supplied product data.
Application Questions and Clarification
Q: Is this fixture appropriate for hazardous location lighting?
A: Yes. The fixture is listed under UL 844 Hazardous Locations for the stated Class I, Class II, and Class III classifications.
Q: Can this fixture be used for marine environment lighting?
A: The fixture is UL 1598A Marine Outside Type listed and ABS certified. It also has an IP66 rating and stainless steel housing.
Q: What should be confirmed for oil and gas facility lighting layouts?
A: Confirm the hazardous location classification, supply voltage, mounting location, mounting height, target light levels, and layout requirements for the installation.
Web ID: 2659