30 Watt Explosion Proof Vapor Tight LED Light | 4200 Lumens | Class 1 Div 2 | 5000K | 100-277V | 2 Foot

SKU: MLLG-LED-EXPLR2-30-50-C1D2 Web ID: 1633
Starting at: $590.00

Availability: 18 In Stock Ships 3-5 Days

This 30 Watt explosion proof vapor tight LED fixture is a strong choice for hazardous and demanding industrial environments due to its certified suitability for Class I Division 2, Class II Division 1 and 2, and Class III locations, as well as its robust IP66 and IK10 ratings for water, dust, and impact resistance. Its 4200 lumen output at 5000K with 1-10V dimming and broad 120-degree beam angle supports effective area lighting while replacing less efficient 150 Watt metal halide units. Ideal applications include chemical plants, refineries, marine environments, and wet or washdown areas requiring certified hazardous location protection.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

18 in stock

    Product total

    Options total

    Sub-Total

    Product Specifications

    ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsClass 1 Division 2 - UL844 Certified for Explosive Atmospheres5 Year Unlimited Usage Warranty

    UL Specs

    • UL 844 Hazardous Locations
    • Class I, Division 2, Groups A, B, C, D
    • Class II, Division 1, Groups E, F, G
    • Class II, Division 2, Groups F, G
    • Class III
    • UL 1598 Suitable for Wet Locations
    • UL 1598A Marine Outside Type
    • ABS

    Key Features

    Brand LED Lighting Supply
    Watts 30
    Lumens 4200
    Lumens Per Watt 140
    Replaces 150 Watt Metal Halide
    Voltage 100V-277V
    Color Temperature 5000K
    CRI 80+
    Dimming 1-10V
    Beam Angles (Std) 120°
    Optics Polycarbonate Lens
    Lifespan 50,000 (L70) hours
    Mounting Surface
    Frequency (Hz) 50-60Hz
    Power Factor >.95
    THD < 10%

    Durable Construction

    Housing Stainless Steel
    IP Rating IP66
    IK Rating IK10
    Operating Temperature -40°F to 122°F
    Certifications ETL | Rebate Eligible
    Warranty 5 years

    Measurements

    Dimensions (in) 28.9 X 8.2 X 4.7
    Weight (lbs) 11

    Product Lighting Layout Estimator

    Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

    Project Inputs

    Loading fixture information...

    Estimated Results

    Fixtures --
    Layout --
    Estimated Avg FC --
    Approx. Spacing --
    Fixture Offset --
    Calculation Method: --
    Top-Down Fixture Layout Fixture positions and estimated floor light levels
    Lower estimated FC Near target Higher estimated FC

    Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

    Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

    Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

    Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

    Need Verified Light Levels?

    This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

    Estimator Version 2.9.20

    Product Overview

    This 2-foot explosion proof vapor tight LED light provides 4,200 lumens from 30 watts at 5000K. It is built for hazardous location lighting where a compact, surface-mounted linear fixture is needed.

    The fixture operates on 100-277V and replaces 150-watt metal halide lighting. Its stainless steel housing, polycarbonate lens, IP66 rating, and IK10 impact rating support demanding operating conditions.

    Core Performance and Output

    This fixture delivers 140 lumens per watt with a 120-degree beam distribution. The 80+ CRI, 5000K output, power factor above 0.95, and THD below 10% support stable general illumination on 100-277V, 50-60Hz electrical systems.

    The 4,200-lumen output suits localized and lower-output hazardous location layouts. At low mounting heights or in confined areas, the 120-degree distribution can place more light on the work plane than required.

    Adjustability and Control Options

    1-10V dimming is included. The dimming system allows output adjustment where the connected control equipment is compatible with 1-10V operation.

    The fixture uses a fixed 120-degree beam angle and polycarbonate lens. There are no alternate optical distributions listed for this configuration.

    Longevity and Reliability

    The LED system is rated for 50,000 L70 hours. This rating identifies the point at which output is expected to reach 70% of initial lumens.

    The listed operating temperature range is -40F to 122F. The stainless steel housing, IP66 enclosure rating, and IK10 impact rating address moisture, dust, and physical exposure conditions covered by the product specifications.

    Build Quality and Physical Characteristics

    The fixture has a stainless steel housing and a polycarbonate lens. It measures 28.9 x 8.2 x 4.7 inches and weighs 11 pounds.

    Surface mounting is the listed installation method. The 2-foot linear form factor is suited to layouts that need light distributed along a narrow fixture body rather than from a point-source housing.

    Where This Product Fits Best

    This fixture fits hazardous and classified locations requiring a compact linear vapor tight light with surface mounting. The listed hazardous location classifications and wet-location construction support use in specified industrial and marine-related environments.

    • hazardous location lighting
    • explosion proof lighting
    • chemical processing facility lighting
    • paint booth lighting
    • oil and gas facility lighting
    • refinery lighting
    • marine environment lighting

    IP66 and IK10 ratings support locations exposed to dust, water, and impact. UL 1598A Marine Outside Type and ABS are listed for this fixture.

    Installation and Long-Term Use

    Surface mounting requires a supporting structure that can carry the 11-pound fixture and maintain the intended orientation. Confirm the mounting surface, supply voltage, and 1-10V control wiring requirements before installation.

    Use the supplied dimensions when checking clearances around structural members, conduit, and equipment. Long-term service access should allow lens cleaning, fixture inspection, and replacement work without disturbing adjacent equipment.

    How This Fixture Is Commonly Used

    In hazardous location lighting, explosion proof lighting, and paint booth lighting, this fixture is surface mounted where its linear shape follows the equipment or structural layout. Mounting height should be established from the required light level and the available mounting surface.

    For chemical processing facility lighting, oil and gas facility lighting, refinery lighting, and marine environment lighting, layouts commonly follow the physical arrangement of the area being illuminated. Spacing varies with mounting height, target light levels, and the 120-degree distribution.

    Safety, Certifications, and Warranty

    UL 844 Hazardous Locations. Class I, Division 2, Groups A, B, C, D. Class II, Division 1, Groups E, F, G. Class II, Division 2, Groups F, G. Class III.

    UL 1598 Suitable for Wet Locations. UL 1598A Marine Outside Type. ABS. ETL. Rebate eligible.

    This fixture includes a 5-year warranty.

    Frequently Asked Questions

    Q: What is the light output of this fixture?

    A: This fixture delivers 4,200 lumens while consuming 30 watts.

    Q: What voltage does this explosion proof vapor tight light use?

    A: It operates on 100-277V, 50-60Hz power.

    Q: Can this fixture be dimmed?

    A: Yes. It has 1-10V dimming.

    Q: What mounting method is listed?

    A: Surface mounting is the listed mounting method.

    Q: What should be considered when planning fixture spacing?

    A: Mounting height, target light levels, and the 120-degree beam distribution affect spacing. The supplied product data does not establish a specific spacing value.

    Application Questions and Clarification

    Q: Is this fixture listed for hazardous location lighting?

    A: Yes. It is listed to UL 844 Hazardous Locations with Class I, Division 2, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class II, Division 2, Groups F, G; and Class III classifications.

    Q: Can this fixture be considered for marine environment lighting?

    A: UL 1598A Marine Outside Type and ABS are listed for this fixture. Final application fit should account for the site conditions and required classification.

    Q: What conditions should be confirmed for chemical processing facility lighting?

    A: Confirm the required hazardous location classification, available 100-277V power, mounting surface, and required light level. The fixture is rated for operation from -40F to 122F.

    Web ID: 1633

    You may also like