This 30 watt, 2 foot explosion proof linear LED fixture is a strong choice for hazardous locations requiring reliable, efficient lighting with robust safety certifications. Delivering 4800 lumens at 160 lumens per watt and a 5000K color temperature, it provides bright, wide-area illumination with reduced glare thanks to its frosted lens and 120 degree beam angle. The IP66 and IK08 ratings ensure durability against water, dust, and impacts, while the fiberglass reinforced polycarbonate housing resists corrosion. Its compact size, flexible mounting options, and broad certification make it ideal for chemical plants, refineries, paint shops, grain facilities, and marine environments.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

94 in stock

Product total

Options total

Sub-Total

Product Specifications

UL Listed - Verified for Electrical Safety and PerformanceClass 1 Division 2 - UL844 Certified for Explosive Atmospheres5 Year Unlimited Usage Warranty

Key Features

Brand LED Lighting Supply
Watts 30
Lumens 4800
Lumens Per Watt 160
Replaces 175 Watt Metal Halide
Voltage 100V-277V
Color Temperature 5000K
CRI 70+
Dimming 1-10V
Beam Angles (Std) 120°
Optics Frosted Polycarbonate Lens
Lifespan 150,000 (L70) hours
Mounting Surface or Trunnion or 3/4 in NPT Pendant
Fixture Color Gray
Frequency (Hz) 50/60
Power Factor >.90
THD < 10%

Durable Construction

Housing Fiberglass reinforced polycarbonate
IP Rating IP66
IK Rating IK08
Surge Protection 6kV
Operating Temperature -31°F to 131°F
Certifications UL
Warranty 5 years

Measurements

Dimensions (in) 24.3 x 4.7 x 4.8
Weight (lbs) 7.7
Cord Length No Cord

Download IES Files

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.20

Product Overview

This 30-watt explosion proof linear LED light delivers 4,800 lumens at 5000K through a frosted polycarbonate lens. The 2-foot fixture is built for hazardous location lighting where a compact linear form factor and certified hazardous-location construction are required.

It operates on 100-277V input and replaces a 175-watt metal halide fixture. Surface, trunnion, and 3/4 inch NPT pendant mounting support different installation conditions.

Core Performance and Output

The fixture produces 4,800 lumens at 160 lumens per watt with a 120-degree beam angle. Its 5000K output and 70+ CRI provide a cool white light distribution for defined work areas and equipment zones.

Electrical performance includes 100-277V operation, 50/60Hz frequency, power factor above 0.90, and THD below 10 percent. The 4,800-lumen output is better suited to localized layouts than large-area coverage from high mounting positions.

Adjustability and Control Options

This fixture supports 1-10V dimming. Dimming control requires a compatible 1-10V control system.

Mounting options include surface mounting, trunnion mounting, and 3/4 inch NPT pendant mounting. The standard optical system uses a fixed 120-degree distribution and frosted polycarbonate lens.

Longevity and Reliability

The LED system is rated for 150,000 hours L70 life. The fixture includes 6kV surge protection.

Operating temperature is rated from -31F to 131F. The five-year warranty applies to the fixture.

Build Quality and Physical Characteristics

The housing is fiberglass reinforced polycarbonate with a gray finish. The fixture is rated IP66 and IK08.

Overall dimensions are 24.3 x 4.7 x 4.8 inches, and fixture weight is 7.7 pounds. It is supplied without a cord.

Where This Product Fits Best

This fixture fits hazardous-location installations requiring a compact, wet-location-rated linear light. Its certified construction also supports installations exposed to marine conditions, process areas, and outdoor industrial conditions.

  • hazardous location lighting
  • explosion proof lighting
  • oil and gas facility lighting
  • chemical processing facility lighting
  • paint booth lighting
  • marine environment lighting
  • wastewater treatment lighting

IP66, IK08, UL 844, UL 1598 wet-location suitability, UL 1598A Marine Outside Type, CSA, ATEX, and IECEx ratings are included. The fixture is rated for Class I Division 2 Groups B, C, and D; Class II Division 2 Groups F and G; and Class III.

Installation and Long-Term Use

Surface mounting is used where the fixture follows the mounting plane. Trunnion mounting allows directional positioning, while the 3/4 inch NPT pendant option supports pendant-mounted installations.

Confirm the selected mounting method, available mounting structure, branch voltage, and 1-10V control requirements before installation. The fixture has no factory-installed cord.

How This Fixture Is Commonly Used

In hazardous location lighting, explosion proof lighting, and chemical processing facility lighting, this 2-foot fixture is placed where focused linear coverage is needed rather than broad high-output coverage. Mounting height is determined by the available structure, required light levels, and the 120-degree beam distribution.

Oil and gas facility lighting, paint booth lighting, marine environment lighting, and wastewater treatment lighting may use surface, trunnion, or pendant layouts based on the installation condition. Fixture spacing varies with mounting height, target light level, and required uniformity.

Safety, Certifications, and Warranty

UL 844 Hazardous Locations. UL 1598 Suitable for Wet Locations. UL 1598A Marine Outside Type.

Class I Division 2 Groups B, C, and D. Class II Division 2 Groups F and G. Class III. CSA, ATEX, and IECEx. Five-year warranty.

Frequently Asked Questions

Q: What is the light output of this explosion proof linear fixture?

A: The fixture uses 30 watts and delivers 4,800 lumens at 160 lumens per watt.

Q: What voltage does this fixture operate on?

A: It operates on 100-277V at 50/60Hz.

Q: Can this fixture be dimmed?

A: Yes. It supports 1-10V dimming.

Q: What mounting options are available?

A: The fixture supports surface mounting, trunnion mounting, and 3/4 inch NPT pendant mounting.

Q: What hazardous-location classifications are listed for this fixture?

A: It is rated for Class I Division 2 Groups B, C, and D; Class II Division 2 Groups F and G; and Class III.

Application Questions and Clarification

Q: Is this fixture appropriate for oil and gas facility lighting?

A: Oil and gas facility lighting is a listed application. The fixture is rated UL 844 and Class I Division 2 Groups B, C, and D.

Q: What should be reviewed when planning fixture placement for hazardous location lighting?

A: Mounting height, target light level, layout requirements, and the 120-degree beam distribution affect fixture placement. A specific spacing value is not established by the supplied product data.