Skip to content

250 Watt Round Explosion Proof LED Light | 35000 Lumens | Class 1 Div 1 | 5000K | 100-277V or 277-480V

SKU: MLLG-E-LED-EXPLC-250-50-[V]-C1D1 Web ID: 1858
Starting at: $1,290.00
100V-277V:44 In StockShips 3-5 Days
277V-480V:Built to Order 6 Weeks

Lighting a large indoor space?

Get a free lighting plan and volume pricing to ensure uniform illumination without overbuying fixtures.

Get Contractor or Bulk Pricing

Get your quote within 1 hour!

Call to Order: (888) 423-3191
This 250W fixture delivers 35,000 lumens at 140 lm/W, making it a practical replacement for 400W metal halide in hazardous areas. Its UL 844 classifications support numerous gas, dust, and fiber locations, while IP66, IK10, 10kV surge protection, and a -22F to 122F operating range suit demanding installations. The 120-degree beam, 1-10V dimming, and yoke or pendant mounting fit hazardous-location and paint booth lighting.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

    Product total

    Options total

    Sub-Total

    Product Specifications

    ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsClass 1 Division 1 - UL844 Certified for Hazardous Locations5 Year Unlimited Usage Warranty

    UL Specs

    • UL 844 Hazardous Locations
    • Class I, Division 1, Groups C,D
    • Class I, Division 2, Groups A, B, C, D
    • Class II, Division 1, Groups E, F, G
    • Class II, Division 2, Groups F, G
    • Class III
    • UL 1598 Suitable for Wet Locations
    • UL 1598A Marine Outside Type
    • ABS

    ATEX Marking

    • II 2 G D
    • Ex db IIB T6...T3 Gb
    • Ex tb IIIC T80°C...T195°C Db

    IECEx Marking

    • Ex db IIB T6...T3 Gb
    • Ex tb IIIC T80°C...T195°C Db

    Key Features

    BrandLED Lighting Supply
    Watts250
    Lumens35000
    Lumens Per Watt140
    Replaces400 Watt Metal Halide
    Voltage100V-277V or 277V-480V
    Color Temperature5000K
    CRI70+
    Dimming1-10V
    Beam Angles (Std)120°
    OpticsTempered Glass Lens
    Lifespan50,000 (L70) hours
    MountingYoke or 3/4 in NPT Pendant
    Fixture ColorGray
    Frequency (Hz)50-60Hz
    Power Factor>.95
    THD< 10%

    Durable Construction

    HousingCopper Free Aluminum
    IP RatingIP66
    IK RatingIK10
    Surge Protection10kV
    Operating Temperature-22°F to 122°F
    CertificationsETL | Rebate Eligible
    Warranty5 years

    Measurements

    Dimensions (in)16 D x 13.5 H
    Weight (lbs)39

    Product SKU Variations

    • SKU: MLLG-E-LED-EXPLC-250-50-C1D1
    • SKU: MLLG-E-LED-EXPLC-250-50-HV-C1D1

    Product Lighting Layout Estimator

    Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

    Project Inputs

    Loading fixture information...

    Estimated Results

    Fixtures --
    Layout --
    Estimated Avg FC --
    Approx. Spacing --
    Fixture Offset --
    Calculation Method: --
    Top-Down Fixture Layout Fixture positions and estimated floor light levels
    Lower estimated FC Near target Higher estimated FC

    Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

    Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

    Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

    Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

    Need Verified Light Levels?

    This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

    Estimator Version 2.9.21

    Product Overview

    This 250 watt round LED explosion proof light delivers 35,000 lumens at 5000K for hazardous location lighting, explosion proof lighting, paint booth lighting, and other permitted industrial applications. It is available in 100-277V or 277-480V configurations and can replace a 400 watt metal halide fixture.

    Core Performance and Output

    The fixture provides 140 lumens per watt with a 120 degree beam angle and tempered glass lens. A 70+ CRI supports general industrial visibility where a high-output, wide-distribution hazardous location fixture is needed.

    It operates on 50-60Hz power with a power factor above 0.95 and THD below 10%.

    Adjustability and Control Options

    This explosion proof fixture supports 1-10V dimming. Select either the 100-277V or 277-480V voltage configuration to match the electrical system.

    Longevity and Reliability

    The LED system is rated for 50,000 L70 hours. Its operating temperature range is -22 degrees F to 122 degrees F, with 10kV surge protection for added electrical protection.

    Build Quality and Physical Characteristics

    The gray copper-free aluminum housing is rated IP66 and IK10. The round fixture measures 16 inches in diameter by 13.5 inches high and weighs 39 pounds.

    Mounting options include a yoke mount or 3/4 inch NPT pendant mount.

    Where This Product Fits Best

    This fixture is designed for classified hazardous locations covered by its UL 844 classifications, including Class I, Class II, and Class III locations.

    • hazardous location lighting
    • explosion proof lighting
    • paint booth lighting
    • chemical processing facility lighting
    • oil and gas facility lighting
    • refinery lighting
    • marine environment lighting
    • solvent storage area lighting

    Safety, Certifications, and Warranty

    The fixture is UL 844 certified for Class I, Division 1, Groups C and D; Class I, Division 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; and Class III. It is also UL 1598 suitable for wet locations, UL 1598A Marine Outside Type, ABS, ETL, ATEX, and IECEx rated.

    ATEX marking is II 2 G D, Ex db IIB T6…T3 Gb, and Ex tb IIIC T80 degrees C…T195 degrees C Db. IECEx marking is Ex db IIB T6…T3 Gb and Ex tb IIIC T80 degrees C…T195 degrees C Db. The fixture includes a 5-year warranty and is rebate eligible.

    Frequently Asked Questions

    Q: What mounting options are available for this 250 watt explosion proof light?

    A: This 250 watt round explosion proof LED light is available with a yoke mount or a 3/4 inch NPT pendant mount.

    Q: What hazardous location classifications does this fixture carry?

    A: This fixture is UL 844 certified for Class I Division 1 Groups C and D; Class I Division 2 Groups A, B, C, and D; Class II Division 1 Groups E, F, and G; Class II Division 2 Groups F and G; and Class III locations.

    Web ID: 1858