200 Watt Round Explosion Proof LED Light | 28000 Lumens | Class 1 Div 2 | 5000K | 100-277V

SKU: LLS-EXPLB-200-5-C1D2 Web ID: 2682
Starting at: $783.33

Availability: 15 In Stock Ships 3-5 Days

This 200 watt round explosion proof LED fixture is a strong choice for hazardous industrial environments requiring Class 1 Division 2, Class 2 Division 1 or 2, or Class 3 lighting, thanks to its robust certifications, 28,000 lumen output, and 5000K daylight-white color temperature that supports visibility and safety. Its IP66 and IK08 ratings ensure reliable operation in wet, dusty, and impact-prone areas, while the 1-10V dimming and multiple mounting options offer flexibility for various installations. Ideal for chemical plants, refineries, paint shops, grain processing, wastewater treatment, and marine environments.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

15 in stock (can be backordered)

Product Options

Product total

Options total

Sub-Total

Product Specifications

UL Listed - Verified for Electrical Safety and PerformanceClass 1 Division 2 - UL844 Certified for Explosive Atmospheres5 Year Unlimited Usage Warranty

UL Specs

  • UL 844 Hazardous Locations
  • Class 1 Division 2, Group A,B,C,D
  • Class 2, Division 1, Groups E,F,G
  • Class 2, Division 2, Groups F,G
  • Class 3
  • UL 1598 Suitable for Wet Locations
  • UL 1598A Marine Outside Type
  • CSA, ATEX, IECEX

Key Features

Brand LED Lighting Supply
Watts 200
Lumens 28000
Lumens Per Watt 140
Replaces 1000 Watt Metal Halide
Voltage 100V-277V
Color Temperature 5000K
CRI 70+
Dimming 1-10V
Beam Angles (Std) 120°
Optics Tempered Glass Lens
Lifespan 150,000 (L70) hours
Mounting Yoke or 3/4 in NPT Pendant
Mounting (Opt) Surface or Wall
Fixture Color Gray
Frequency (Hz) 50-60Hz
Power Factor >.90
THD < 10%

Durable Construction

Housing Powder Coated Aluminum
IP Rating IP66
IK Rating IK08
Surge Protection 10kV
Operating Temperature -40°F to 149°F
Certifications UL
Warranty 5 years

Measurements

Dimensions (in) 14.96 W X 14.37 H
Weight (lbs) 20
Cord Length No Cord

Download IES Files

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.20

Product Overview

This 200-watt round explosion proof LED light delivers 28,000 lumens at 5000K for hazardous location lighting where classified-location construction is required. It operates on 100-277V and uses a 120-degree beam distribution.

The fixture is rated for Class I Division 2 Groups A, B, C, and D; Class II Division 1 Groups E, F, and G; Class II Division 2 Groups F and G; and Class III locations. Yoke and 3/4 inch NPT pendant mounting support common hazardous-location installation methods.

Core Performance and Output

The fixture produces 28,000 lumens from 200 watts for an efficacy of 140 lumens per watt. The 5000K color temperature and 70+ CRI support high-output task and area illumination in classified spaces.

A standard 120-degree beam angle distributes light broadly below the fixture. This output can be excessive at low mounting heights, while higher mounting heights can require closer layout review to maintain light levels and uniformity.

The driver operates at 100-277V, 50-60Hz, with power factor above 0.90 and THD below 10 percent. It includes 1-10V dimming capability and 10kV surge protection.

Adjustability and Control Options

1-10V dimming is available for installations using compatible dimming controls. Dimming wiring and control equipment must be suitable for the classified location and installation method.

The fixture uses a fixed 120-degree beam angle. There are no listed field-adjustable wattage or beam-angle settings.

Longevity and Reliability

The LED system is rated for 150,000 L70 hours. This rating supports long operating intervals where fixture access can be limited by hazardous-location installation requirements.

The fixture operates from -40 degrees F to 149 degrees F. A 10kV surge protection rating helps address electrical surge exposure.

Build Quality and Physical Characteristics

The housing is powder-coated aluminum with a gray finish. A tempered glass lens protects the optical assembly.

The fixture is IP66 rated and IK08 rated. It measures 14.96 inches wide by 14.37 inches high and weighs 20 pounds.

Standard mounting is yoke or 3/4 inch NPT pendant. Surface and wall mounting are listed as optional configurations. No cord is included.

Where This Product Fits Best

This fixture fits classified industrial and process environments requiring high-output explosion proof lighting, wet-location suitability, and durable enclosed construction.

  • hazardous location lighting
  • paint booth lighting
  • chemical processing facility lighting
  • oil and gas facility lighting
  • refinery lighting
  • marine environment lighting

Its IP66 rating, UL 1598 wet-location suitability, UL 1598A Marine Outside Type rating, and -40 degrees F to 149 degrees F operating range support demanding environmental conditions.

Installation and Long-Term Use

Fixture weight, mounting method, supply voltage, and classified-location requirements should be verified before installation. The yoke and 3/4 inch NPT pendant options require a mounting structure and conduit arrangement appropriate for the selected configuration.

Installations using 1-10V dimming require control wiring compatible with the fixture and location requirements. The fixture has no factory cord, so field wiring is required.

Long-term maintenance should include inspection of the tempered glass lens, mounting hardware, conduit connections, and enclosure condition.

How This Fixture Is Commonly Used

This fixture is mounted at heights established by the hazardous location lighting layout, target light levels, and available mounting structure. Yoke mounting supports directional aiming, while 3/4 inch NPT pendant mounting places the fixture below the mounting point.

Layouts typically use the 120-degree distribution to overlap light between fixtures across the intended work area. Spacing varies with mounting height, required light levels, and the selected mounting configuration.

Higher output can reduce fixture count in a layout, but the final arrangement must control glare and maintain uniformity across the illuminated area.

Safety, Certifications, and Warranty

UL 844 Hazardous Locations. Class I Division 2 Groups A, B, C, D. Class II Division 1 Groups E, F, G. Class II Division 2 Groups F, G. Class III.

UL 1598 Suitable for Wet Locations. UL 1598A Marine Outside Type. CSA. ATEX. IECEx.

The fixture includes a 5-year warranty.

Frequently Asked Questions

Q: What is the light output of this explosion proof fixture?

A: The fixture delivers 28,000 lumens while operating at 200 watts.

Q: What voltage does this fixture use?

A: The fixture operates on 100-277V at 50-60Hz.

Q: What mounting options are available?

A: Standard mounting options are yoke and 3/4 inch NPT pendant. Surface and wall mounting are listed as optional.

Q: What information is needed to plan the fixture layout?

A: Layout planning requires the mounting height, target light levels, mounting configuration, and the fixture’s 28,000-lumen output with 120-degree beam angle.

Application Questions and Clarification

Q: Is this fixture suitable for hazardous location lighting?

A: The fixture is rated for Class I Division 2 Groups A, B, C, and D; Class II Division 1 Groups E, F, and G; Class II Division 2 Groups F and G; and Class III locations.

Q: What should be confirmed for paint booth lighting or chemical processing facility lighting?

A: Confirm the location classification, available supply voltage, mounting method, and required fixture layout before final selection.

Q: Can this fixture be used for marine environment lighting?

A: The fixture is UL 1598A Marine Outside Type rated and has an IP66 rating.

Web ID: 2682

You may also like