200 Watt Round Explosion Proof LED Light | 28000 Lumens | Class 1 Div 1 | 5000K | 100-277V or 277-480V

SKU: MLLG-E-LED-EXPLC-200-50-[V]-C1D1 Web ID: 2175
Starting at: $1,150.00

 

100V-277V:37 In StockShips 3-5 Days

 

277V-480V:Built to Order 6 Weeks
This 200 watt hazardous location LED fixture is a strong choice for demanding industrial and marine environments where safety, durability, and reliable performance are critical. With 28,000 lumens at 140 lumens per watt, it directly replaces 400 watt metal halide systems, providing wide 120° coverage and consistent daylight-white output. Its UL 844, UL 1598, UL 1598A, ABS, ATEX, and IECEx certifications support use in classified hazardous, wet, and marine locations, while the IP66 and IK10 ratings ensure resilience against dust, water, and impact. Ideal applications include chemical plants, refineries, marine terminals, and other hazardous or outdoor industrial sites.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

Product total

Options total

Sub-Total

Product Specifications

ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsClass 1 Division 1 - UL844 Certified for Hazardous Locations5 Year Unlimited Usage Warranty

UL Specs

  • UL 844 Hazardous Locations
  • Class I, Division 1, Groups C,D
  • Class I, Division 2, Groups A, B, C, D
  • Class II, Division 1, Groups E, F, G
  • Class II, Division 2, Groups F, G
  • Class III
  • UL 1598 Suitable for Wet Locations
  • UL 1598A Marine Outside Type
  • ABS

ATEX Marking

  • II 2 G D
  • Ex db IIB T6…T3 Gb
  • Ex tb IIIC T80°C…T195°C Db

IECEx Marking

  • Ex db IIB T6…T3 Gb
  • Ex tb IIIC T80°C…T195°C Db

Key Features

Brand LED Lighting Supply
Watts 200
Lumens 28000
Lumens Per Watt 140
Replaces 400 Watt Metal Halide
Voltage 100V-277V or 277V-480V
Color Temperature 5000K
CRI 70+
Dimming 1-10V
Beam Angles (Std) 120°
Optics Tempered Glass Lens
Lifespan 50,000 (L70) hours
Mounting Yoke or 3/4 in NPT Pendant
Fixture Color Gray
Frequency (Hz) 50-60Hz
Power Factor >.95
THD < 10%

Durable Construction

Housing Copper Free Aluminum
Housing C
IP Rating IP66
IK Rating IK10
Surge Protection 10kV
Operating Temperature -22°F to 122°F
Certifications ETL | Rebate Eligible
Warranty 5 years

Measurements

Dimensions (in) 16 x 13.5
Weight (lbs) 39

 

Product SKU Variations

  • SKU: MLLG-E-LED-EXPLC-200-50-C1D1
  • SKU: MLLG-E-LED-EXPLC-200-50-HV-C1D1

 

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.20

Product Overview

This 200 watt round explosion proof LED light provides 28,000 lumens at 5000K for hazardous location lighting. It is built for Class I, II, and III hazardous locations with a 120 degree distribution and tempered glass lens. The fixture is commonly used for oil and gas facility lighting, chemical processing facility lighting, refinery lighting, and paint booth lighting where a standard high bay is not appropriate. It replaces 400 watt metal halide fixtures.

Core Performance and Output

Output is 28,000 lumens from 200 watts, producing 140 lumens per watt. The 5000K color temperature and 70+ CRI provide a neutral white operating light. The standard 120 degree beam angle distributes light across broad work areas. At lower mounting heights, this output can create excessive brightness if fixture locations are not planned around the work plane. The fixture operates on 100-277V or 277-480V power at 50-60Hz. Power factor is greater than 0.95 and total harmonic distortion is below 10%.

Adjustability and Control Options

This fixture supports 1-10V dimming. Dimming capability allows output adjustment where the connected control system supports 1-10V control. Voltage selection must match the available site electrical system. The fixture is available in 100-277V and 277-480V configurations.

Longevity and Reliability

Rated life is 50,000 hours L70. The fixture includes 10kV surge protection for electrical transient protection. Operating temperature range is -22F to 122F. The 5 year warranty applies to the fixture.

Build Quality and Physical Characteristics

The housing is copper free aluminum with a gray finish. The fixture measures 16 x 13.5 inches and weighs 39 pounds. An IP66 rating and IK10 impact rating support use in demanding hazardous location environments. The tempered glass lens protects the optical assembly.

Where This Product Fits Best

This fixture fits hazardous environments requiring classified-location lighting, wet-location suitability, and a high-output round fixture. Its construction also supports marine environment lighting and offshore rig lighting.
  • hazardous location lighting
  • chemical processing facility lighting
  • oil and gas facility lighting
  • refinery lighting
  • paint booth lighting
  • marine environment lighting
  • offshore rig lighting
UL 844 hazardous location ratings cover Class I, Division 1 Groups C and D; Class I, Division 2 Groups A, B, C, and D; Class II; and Class III classifications. The fixture is UL 1598 suitable for wet locations and UL 1598A Marine Outside Type.

Installation and Long-Term Use

Mounting options are yoke mounting or 3/4 inch NPT pendant mounting. The 39 pound fixture weight and selected mounting method need to be accounted for during installation. Installers should confirm the fixture voltage configuration, hazardous location classification, and mounting arrangement before installation. Long-term service access should be considered when establishing fixture locations.

How This Fixture Is Commonly Used

In hazardous location lighting and explosion proof lighting layouts, fixtures are positioned around the mounting height, target light level, and equipment or process areas requiring illumination. The broad 120 degree distribution is suited to layouts needing wide light spread from each fixture. Oil and gas facility lighting, refinery lighting, and chemical processing facility lighting layouts often require fixture placement around classified boundaries and available mounting points. Higher output can reduce fixture count, but spacing and mounting height still affect uniformity and brightness.

Safety, Certifications, and Warranty

Certifications and ratings include UL 844 Hazardous Locations, UL 1598 Suitable for Wet Locations, UL 1598A Marine Outside Type, ABS, ATEX, IECEx, ETL, IP66, and IK10. ATEX marking is II 2 G D, Ex db IIB T6…T3 Gb, and Ex tb IIIC T80C…T195C Db. IECEx marking is Ex db IIB T6…T3 Gb and Ex tb IIIC T80C…T195C Db. Warranty is 5 years.

Frequently Asked Questions

Q: What output does this explosion proof LED light provide? A: The fixture uses 200 watts and produces 28,000 lumens at 140 lumens per watt. Q: What hazardous location classifications are listed for this fixture? A: It is UL 844 rated for Class I, Division 1 Groups C and D; Class I, Division 2 Groups A, B, C, and D; Class II, Division 1 Groups E, F, and G; Class II, Division 2 Groups F and G; and Class III. Q: What mounting options are available? A: The fixture is available with yoke mounting or 3/4 inch NPT pendant mounting. Q: Can this fixture be dimmed? A: Yes. The fixture supports 1-10V dimming.

Application Questions and Clarification

Q: Is this fixture suited for oil and gas facility lighting? A: Oil and gas facility lighting is a listed application. Final fit depends on confirming the hazardous location classification against the fixture’s UL 844 ratings. Q: What should be considered when planning fixture placement for hazardous location lighting? A: Mounting height, target light levels, mounting locations, and the 120 degree beam distribution affect placement. A specific spacing value is not established by the supplied product data. Q: Can this fixture be used for marine environment lighting? A: Marine environment lighting is a listed application. The fixture is UL 1598A Marine Outside Type and has an IP66 rating. Web ID: 2175

You may also like