100 Watt Round Explosion Proof LED Light | 14000 Lumens | Class 1 Div 2 | 5000K | 100V-277V | NSF Rated
Product Specifications
UL Specs
- UL 844 Hazardous Locations
- Class I, Division 2, Groups A, B, C, D
- Class II, Division 1, Groups E, F, G
- Class II, Division 2, Groups F, G
- Class III
- UL 1598 Suitable for Wet Locations
- UL 1598A Marine Outside Type
- ABS
- NSF
Key Features
| Brand | LED Lighting Supply |
| Watts | 100 |
| Lumens | 14000 |
| Lumens Per Watt | 140 |
| Replaces | 400 Watt Metal Halide |
| Voltage | 100V-277V |
| Color Temperature | 5000K |
| CRI | 80+ |
| Dimming | 1-10V |
| Beam Angles (Std) | 120° |
| Optics | Polycarbonate Lens |
| Lifespan | 50,000 (L70) hours |
| Mounting | 3/4 in NPT Pendant |
| Frequency (Hz) | 50-60Hz |
| Power Factor | >.95 |
Durable Construction
| Housing | Copper Free Aluminum |
| IP Rating | IP66 |
| IK Rating | IK10 |
| Surge Protection | 10kV |
| Operating Temperature | -40°F to 140°F |
| Certifications | ETL | Rebate Eligible | NSF Rated |
| Warranty | 5 years |
Measurements
| Dimensions (in) | 12.6 D X 9.2 H |
| Weight (lbs) | 22.60 |
Features/Accessories
- NSF Rated Food Grade
Download IES Files
Product Lighting Layout Estimator
Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.
Project Inputs
Estimated Results
Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.
Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.
Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.
Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.
This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.
Product Overview
This 100-watt round explosion proof LED light delivers 14,000 lumens at 5000K for hazardous location lighting where classified-location ratings, wet-location construction, and impact resistance are required. The round fixture uses a 3/4 in NPT pendant mount and operates on 100V-277V power.
The fixture replaces a 400-watt metal halide fixture while reducing connected load. Its NSF rating, IP66 enclosure, and copper-free aluminum housing support demanding industrial and marine operating conditions.
Core Performance and Output
This fixture produces 14,000 lumens at 140 lumens per watt. The 120 degree beam distribution provides broad downward light from a pendant-mounted position, with an 80+ CRI and 5000K color temperature.
Input voltage is 100V-277V at 50-60Hz, with a power factor above 0.95. The fixture includes 10kV surge protection and 1-10V dimming.
The 14,000-lumen output can be excessive where mounting positions are low or closely spaced. Higher mounting positions require layout review to maintain uniformity across the intended area.
Adjustability and Control Options
The fixture supports 1-10V dimming. Dimming controls must match the fixture’s 1-10V control input.
The standard optic is a polycarbonate lens with a 120 degree beam angle. This configuration provides a fixed broad distribution rather than an adjustable beam pattern.
Longevity and Reliability
Rated life is 50,000 L70 hours. The operating temperature range is -40 degrees F to 140 degrees F.
The fixture includes 10kV surge protection. Its sealed IP66 construction limits exposure to dust and water ingress during long-term operation.
Build Quality and Physical Characteristics
The housing is copper-free aluminum with an IK10 impact rating. The polycarbonate lens protects the optical assembly.
This fixture measures 12.6 inches in diameter by 9.2 inches high and weighs 22.60 pounds. Mounting is through a 3/4 in NPT pendant connection.
Where This Product Fits Best
This fixture fits classified industrial, processing, and marine environments that require explosion proof lighting or hazardous location lighting. Its listed Class I, Class II, and Class III ratings support use where the applicable classification matches the installation.
- hazardous location lighting
- explosion proof lighting
- paint booth lighting
- chemical processing facility lighting
- oil and gas facility lighting
- marine environment lighting
IP66, IK10, NSF, ABS, UL 844, UL 1598, and UL 1598A ratings are listed for this fixture. The final installation must match the applicable area classification and mounting conditions.
Installation and Long-Term Use
The fixture installs through its 3/4 in NPT pendant mount. The mounting structure and conduit arrangement must support the 22.60-pound fixture weight and suit the classified installation.
Use the 100V-277V electrical range and 1-10V dimming connections only where the site electrical system and controls match the fixture specifications. Maintain access for inspection, cleaning, and future driver or fixture service.
How This Fixture Is Commonly Used
In hazardous location lighting, explosion proof lighting, paint booth lighting, and chemical processing facility lighting, fixtures are placed from pendant mounting positions to direct the 120 degree distribution into the working area. Layouts are arranged around the required light level, mounting position, and classified-area boundaries.
Oil and gas facility lighting and marine environment lighting installations require attention to fixture placement, conduit routing, and service access. Wider spacing can reduce fixture count, but uniformity depends on mounting position and the 120 degree distribution.
Safety, Certifications, and Warranty
UL 844 Hazardous Locations. Class I, Division 2, Groups A, B, C, D. Class II, Division 1, Groups E, F, G. Class II, Division 2, Groups F, G. Class III.
UL 1598 Suitable for Wet Locations. UL 1598A Marine Outside Type. ABS. NSF. ETL. IP66. IK10. Warranty: 5 years.
Frequently Asked Questions
Q: What light output does this explosion proof fixture provide?
A: The fixture uses 100 watts and produces 14,000 lumens at 5000K with an 80+ CRI.
Q: What voltage does this fixture require?
A: The fixture operates on 100V-277V, 50-60Hz power.
Q: Can this fixture be dimmed?
A: Yes. The fixture supports 1-10V dimming.
Q: What mounting connection does this fixture use?
A: The fixture uses a 3/4 in NPT pendant mount.
Q: What should be considered when planning the fixture layout?
A: The 14,000-lumen output, 120 degree beam angle, mounting position, and target light levels affect layout planning. The supplied data does not establish a fixed spacing value or fixture quantity.
Application Questions and Clarification
Q: Is this fixture listed for hazardous location lighting?
A: Yes. The fixture is UL 844 listed and rated for Class I, Division 2, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class II, Division 2, Groups F, G; and Class III.
Q: What should be verified for paint booth lighting or chemical processing facility lighting?
A: Verify that the site classification matches the fixture’s listed Class and Division ratings, and confirm that the 3/4 in NPT pendant mounting arrangement matches the installation.
Q: What conditions support use in marine environment lighting?
A: The fixture is UL 1598A Marine Outside Type listed, ABS rated, IP66 rated, and constructed with a copper-free aluminum housing.
Web ID: 2491