100 Watt Round Explosion Proof LED Light | 14000 Lumens | Class 1 Div 1 | 5000K | 100-277V or 277-480V

SKU: MLLG-E-LED-EXPLC-100-50-[V]-C1D1 Web ID: 1747
Starting at: $1,050.00

100V-277V:369 In StockShips 3-5 Days

277V-480V:Built to Order 6 Weeks

This 100-watt hazardous location LED fixture is a strong choice for demanding industrial and marine environments where explosive gases, vapors, or dusts are present, thanks to its UL 844, UL 1598, UL 1598A, ABS, ATEX, and IECEx certifications. Delivering 14,000 lumens at 140 lumens per watt, it efficiently replaces 250-watt metal halide fixtures while supporting 1-10V dimming for operational flexibility. The copper-free aluminum housing, tempered glass lens, IP66, and IK10 ratings ensure durability against water, dust, corrosion, and impact. It is well-suited for chemical plants, refineries, grain processing, marine terminals, and similar hazardous or wet locations.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

    Product total

    Options total

    Sub-Total

    Product Specifications

    ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsClass 1 Division 1 - UL844 Certified for Hazardous Locations5 Year Unlimited Usage Warranty

    UL Specs

    • UL 844 Hazardous Locations
    • Class I, Division 1, Groups C,D
    • Class I, Division 2, Groups A, B, C, D
    • Class II, Division 1, Groups E, F, G
    • Class II, Division 2, Groups F, G
    • Class III
    • UL 1598 Suitable for Wet Locations
    • UL 1598A Marine Outside Type
    • ABS

    ATEX Marking

    • II 2 G D
    • Ex db IIB T6…T3 Gb
    • Ex tb IIIC T80°C…T195°C Db

    IECEx Marking

    • Ex db IIB T6…T3 Gb
    • Ex tb IIIC T80°C…T195°C Db

    Key Features

    Brand LED Lighting Supply
    Watts 100
    Lumens 14000
    Lumens Per Watt 140
    Replaces 250 Watt Metal Halide
    Voltage 100V-277V or 277V-480V
    Color Temperature 5000K
    CRI 70+
    Dimming 1-10V
    Beam Angles (Std) 120°
    Optics Tempered Glass Lens
    Lifespan 50,000 (L70) hours
    Mounting Yoke or 3/4 in NPT Pendant
    Fixture Color Gray
    Frequency (Hz) 50-60Hz
    Power Factor >.95
    THD < 10%

    Durable Construction

    Housing Copper Free Aluminum
    IP Rating IP66
    IK Rating IK10
    Surge Protection 10kV
    Operating Temperature -22°F to 122°F
    Certifications ETL | Rebate Eligible
    Warranty 5 years

    Measurements

    Dimensions (in) 16 X 13.5
    Weight (lbs) 39

    Product SKU Variations

    • SKU: MLLG-E-LED-EXPLC-100-50-C1D1
    • SKU: MLLG-E-LED-EXPLC-100-50-HV-C1D1

    Product Lighting Layout Estimator

    Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

    Project Inputs

    Loading fixture information...

    Estimated Results

    Fixtures --
    Layout --
    Estimated Avg FC --
    Approx. Spacing --
    Fixture Offset --
    Calculation Method: --
    Top-Down Fixture Layout Fixture positions and estimated floor light levels
    Lower estimated FC Near target Higher estimated FC

    Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

    Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

    Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

    Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

    Need Verified Light Levels?

    This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

    Estimator Version 2.9.20

    Product Overview

    This 100-watt round explosion proof LED light delivers 14,000 lumens at 5000K for hazardous location lighting, explosion proof lighting, paint booth lighting, and chemical processing facility lighting. It is available in 100-277V or 277-480V configurations.

    The fixture replaces a 250-watt metal halide fixture and uses a 120-degree beam distribution. Yoke and 3/4-inch NPT pendant mounting support different fixture positioning requirements.

    Core Performance and Output

    The fixture produces 14,000 lumens at 140 lumens per watt. Its 5000K color temperature and 70+ CRI provide a neutral white output for industrial hazardous locations.

    A 120-degree beam angle supports broad distribution from overhead mounting locations. This output can be excessive at low mounting heights, while higher mounting locations may require closer layout review to maintain uniformity.

    Adjustability and Control Options

    This fixture supports 1-10V dimming. Dimming control wiring should be planned with the selected voltage configuration and hazardous-location installation requirements.

    The fixture is available with a yoke mount or 3/4-inch NPT pendant mount. The mounting method affects aiming, fixture orientation, and final layout flexibility.

    Longevity and Reliability

    The rated life is 50,000 hours at L70. The fixture includes 10kV surge protection and operates from -22 degrees F to 122 degrees F.

    A power factor above 0.95 and total harmonic distortion below 10 percent support electrical performance on 50-60Hz systems. Long-term operation depends on maintaining the fixture, mounting components, and electrical connections in serviceable condition.

    Build Quality and Physical Characteristics

    The housing is copper-free aluminum with a gray finish. A tempered glass lens protects the optical assembly.

    This fixture is rated IP66 and IK10. It measures 16 by 13.5 inches and weighs 39 pounds, so the mounting location and support method must accommodate the fixture weight.

    Where This Product Fits Best

    This fixture fits hazardous and classified environments where explosion proof lighting construction, wet-location suitability, and durable enclosure protection are required. The 100-watt output suits installations needing a moderate-output round fixture.

    • hazardous location lighting
    • explosion proof lighting
    • paint booth lighting
    • chemical processing facility lighting
    • oil and gas facility lighting
    • refinery lighting
    • solvent storage area lighting

    Its IP66 rating, IK10 rating, marine outside type listing, and operating temperature range support demanding environmental conditions covered by its listed classifications.

    Installation and Long-Term Use

    Install the fixture using the yoke mount or 3/4-inch NPT pendant mount. Confirm the selected voltage version, mounting support, and fixture orientation before installation.

    The 39-pound fixture requires secure mounting hardware and support structure. Access for future inspection, cleaning, and electrical service should be considered during layout planning.

    How This Fixture Is Commonly Used

    In hazardous location lighting and explosion proof lighting layouts, fixtures are mounted overhead using pendant or yoke mounting based on the available structure and required aiming. Paint booth lighting and chemical processing facility lighting installations use the 120-degree distribution to establish broad light coverage.

    Fixture spacing and layout depend on mounting height, target light levels, and the selected mounting method. Higher output can reduce fixture count, but layout review is needed to control glare and maintain uniformity.

    Safety, Certifications, and Warranty

    UL 844 Hazardous Locations. Class I, Division 1, Groups C and D. Class I, Division 2, Groups A, B, C, and D. Class II, Division 1, Groups E, F, and G. Class II, Division 2, Groups F and G. Class III.

    UL 1598 Suitable for Wet Locations. UL 1598A Marine Outside Type. ABS. ATEX. IECEx. ETL. Rebate eligible. The warranty is 5 years.

    Frequently Asked Questions

    Q: What is the light output of this explosion proof fixture?

    A: The fixture delivers 14,000 lumens while operating at 100 watts.

    Q: What voltage configurations are available?

    A: The fixture is available in 100-277V or 277-480V configurations.

    Q: Can this fixture be dimmed?

    A: Yes. It supports 1-10V dimming.

    Q: What mounting options are available?

    A: The fixture is available with a yoke mount or a 3/4-inch NPT pendant mount.

    Q: What should be considered when planning fixture layout?

    A: Mounting height, target light levels, the 120-degree beam angle, and fixture orientation affect the final layout. The supplied data does not establish a specific spacing value or fixture quantity.

    Application Questions and Clarification

    Q: Is this fixture appropriate for paint booth lighting?

    A: Paint booth lighting is a listed primary application for this explosion proof fixture.

    Q: Can this fixture be used for oil and gas facility lighting?

    A: Oil and gas facility lighting is a listed secondary application. Final application fit must align with the fixture’s stated hazardous-location classifications.

    Q: What should be confirmed for chemical processing facility lighting?

    A: Confirm the required hazardous-location classification, selected voltage configuration, mounting method, and layout requirements. Chemical processing facility lighting is a listed primary application.

    Web ID: 1747

    You may also like