80 Watt Round High Temperature Explosion Proof LED Light | 8000 Lumens | Class 1 Div 2 | 5000K | 120V | Rated to 194F

SKU: MLLG-E-LED-EXPLB-80-50-C1D2-HT Web ID: 2302
Starting at: $880.70

Built to Order 8 Weeks

This 80 watt round explosion proof LED fixture is a strong choice for hazardous locations requiring Class I Division 2, Class II Division 1 or 2, and Class III protection, especially where high ambient temperatures up to 194°F are present. Its 8000 lumen output at 5000K with a wide 120° beam angle ensures even illumination in process areas, foundries, or industrial spaces exposed to explosive gases, dust, water jets, or physical impacts. The IP66 and IK10 ratings, copper-free aluminum housing, and tempered glass lens support durability in harsh environments. Note, this fixture is non-dimmable and operates only on 120V.

Dwayne Kula | President, CTO and Founder

Product Specifications

ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsClass 1 Division 2 - UL844 Certified for Explosive Atmospheres5 Year Unlimited Usage Warranty

UL Specs

  • UL 844 Hazardous Locations
  • Class I, Division 2, Groups A, B, C, D
  • Class II, Division 1, Groups E, F, G
  • Class II, Division 2, Groups F, G
  • Class III
  • UL 1598 Suitable for Wet Locations
  • UL 1598A Marine Outside Type
  • ABS

Key Features

Brand LED Lighting Supply
Watts 80
Lumens 8000
Lumens Per Watt 100
Replaces 250 Watt Metal Halide
Voltage 120V
Color Temperature 5000K
CRI 70+
Dimming No
Beam Angles (Std) 120°
Optics Tempered Glass Lens
Lifespan 50,000 (L70) hours
Mounting Yoke or 3/4 in NPT Pendant
Fixture Color Gray
Frequency (Hz) 50-60Hz
Power Factor >.95
THD < 10%

Durable Construction

Housing Copper Free Aluminum
IP Rating IP66
IK Rating IK10
Surge Protection 10kV
Operating Temperature -40°F to 194°F
Certifications ETL | Rebate Eligible
Warranty 5 years

Measurements

Dimensions (in) 9.1 X 8.7
Weight (lbs) 15 lbs

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.20

Product Overview

This 80-watt round high temperature explosion proof LED light delivers 8,000 lumens at 5000K for high temperature facility lighting and classified locations. It operates on 120V and is rated for ambient temperatures from -40F to 194F.

The fixture combines hazardous-location classifications with a compact round housing, tempered glass lens, and 120-degree beam distribution. It is a 250-watt metal halide replacement where the existing electrical system is 120V.

Core Performance and Output

The fixture produces 8,000 lumens from 80 watts, delivering 100 lumens per watt. A 5000K color temperature and 70+ CRI provide a cool white output for industrial visual tasks.

The standard 120-degree beam angle spreads light broadly from yoke or pendant mounting positions. This output can be excessive at low mounting heights, while mounting from higher positions requires layout review to maintain uniformity.

Electrical operation is 120V, 50-60Hz, with power factor above 0.95 and THD below 10%. This fixture does not include dimming.

Adjustability and Control Options

This fixture is a fixed-output 80-watt unit with no dimming function. Output selection and control changes are not available within this configuration.

The 120-degree optic is standard and uses a tempered glass lens. Yoke mounting allows aiming adjustment, while the 3/4 inch NPT pendant mount positions the fixture downward.

Longevity and Reliability

The LED system is rated for 50,000 L70 hours. The fixture includes 10kV surge protection.

Its operating temperature range is -40F to 194F. This rating supports high temperature facility lighting where ambient heat is a primary operating condition.

Build Quality and Physical Characteristics

The housing is copper-free aluminum with a gray finish. The fixture measures 9.1 by 8.7 inches and weighs 15 pounds.

An IP66 rating and IK10 impact rating support use in demanding industrial conditions. The tempered glass lens protects the optical assembly.

Where This Product Fits Best

This fixture fits high temperature and hazardous industrial locations where ambient conditions, classified-location requirements, and fixed 120V operation align with the product ratings.

  • industrial furnace area lighting
  • foundry lighting
  • steel mill lighting
  • power plant and energy site lighting
  • kiln lighting
  • boiler room lighting

The fixture is rated for temperatures up to 194F and carries Class I, II, and III hazardous-location classifications. Final placement must account for the actual ambient temperature and location classification.

Installation and Long-Term Use

Installation uses either the yoke mount or 3/4 inch NPT pendant mount. The selected mounting method must support the 15-pound fixture weight and maintain the required aiming or downward orientation.

Verify the available supply is 120V before installation. The fixture is rated IP66 and suitable for wet locations under UL 1598.

Long-term maintenance should include inspection of the tempered glass lens, mounting hardware, and electrical connections. Access planning matters where the fixture is installed near high-temperature equipment.

How This Fixture Is Commonly Used

In industrial furnace area lighting, foundry lighting, and steel mill lighting, fixtures are positioned from available structural mounting points to direct the broad 120-degree distribution across the work area. Yoke mounting is used where aiming adjustment is needed, while pendant mounting supports a fixed downward pattern.

For power plant and energy site lighting, kiln lighting, and boiler room lighting, layout decisions account for mounting height, equipment arrangement, target light levels, and ambient temperature. Spacing varies with mounting height and required light distribution.

Higher output can reduce fixture count in a layout, but broad distribution and mounting position affect glare and uniformity. The supplied data does not establish a fixed mounting height or spacing pattern.

Safety, Certifications, and Warranty

UL 844 Hazardous Locations. Class I, Division 2, Groups A, B, C, D. Class II, Division 1, Groups E, F, G. Class II, Division 2, Groups F, G. Class III.

UL 1598 Suitable for Wet Locations. UL 1598A Marine Outside Type. ABS. ETL. IP66. IK10.

The fixture includes a 5-year warranty. It is rebate eligible.

Frequently Asked Questions

Q: What is the light output of this fixture?

A: This fixture produces 8,000 lumens at 80 watts, or 100 lumens per watt.

Q: What voltage does this fixture require?

A: This fixture operates on 120V, 50-60Hz.

Q: Can this fixture be dimmed?

A: No. This fixture does not include dimming.

Q: What mounting options are available?

A: The fixture is available with yoke mounting or 3/4 inch NPT pendant mounting.

Q: What should be considered when planning fixture placement?

A: Mounting height, equipment arrangement, target light levels, and the 120-degree beam distribution affect placement. The supplied product data does not establish a fixed spacing value or fixture count.

Application Questions and Clarification

Q: Is this fixture suitable for high temperature facility lighting?

A: The fixture is rated for operation from -40F to 194F and is listed for high temperature facility lighting.

Q: Can this fixture be used for industrial furnace area lighting?

A: Industrial furnace area lighting is a listed application. Confirm that the actual ambient temperature remains within the -40F to 194F operating range.

Q: What hazardous-location classifications does this fixture carry?

A: It is UL 844 listed for Class I, Division 2, Groups A, B, C, D; Class II, Division 1, Groups E, F, G; Class II, Division 2, Groups F, G; and Class III locations.

Web ID: 2302

You may also like