50 Watt LED High Temperature Light | 7500 Lumens | 5000K | 100-277V | Rated to 302F

SKU: LLS-LS-HB-HT150-50-50 Web ID: 2165
Starting at: $1,071.91

Built to Order 8 Weeks
This 50W LED high temperature fixture is well suited to power plants and nuclear facilities where ambient conditions can reach 302F. Its 7,500-lumen output, 150 lm/W efficacy, 120-degree beam angle, IP66 aluminum alloy housing, tempered glass lens, and 6kV surge protection support dependable area lighting in demanding environments. Pendant mounting and 100-277V operation simplify installation, while its 100,000-hour L70 life and 5-year warranty support long-term maintenance planning.

Dwayne Kula | President, CTO and Founder

Product Specifications

ETL Listed - Certified for Product Safety Compliance to North American StandardsHigh Temperature Rated - Reliable Operation in Elevated Heat Conditions5 Year Unlimited Usage Warranty

Key Features

Brand LED Lighting Supply
Watts 50
Lumens 7500
Lumens Per Watt 150
Replaces 250 Watt Metal Halide
Voltage 100V-277V
Color Temperature 5000K
CRI 75+
Dimming No
Beam Angles (Std) 120°
Optics Tempered Glass Lens
Lifespan 100,000 (L70) hours
Mounting Pendant
Fixture Color Silver
Frequency (Hz) 50/60 hz
Power Factor > .95
THD < 15%

Durable Construction

Housing Aluminum Alloy
IP Rating IP66
Surge Protection 6kV
Operating Temperature -40°F to 302°F
Certifications ETL
Warranty 5 years

Measurements

Dimensions (in) 12 x 10.5 x 2.5
Weight (lbs) 11 lbs

Options

LLS-LS-HT150-10M: 32 foot (10 meter) cord for remote driver installation

LLS-LS-HT150-15M: 49 foot (15 meter) cord for remote driver installation

LLS-LS-HT150-20M: 68 foot (20 meter) cord for remote driver installation

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.20

Product Overview

This 50-watt LED high temperature light delivers 7,500 lumens at 5000K for elevated-temperature industrial lighting conditions. It is built with an aluminum alloy housing, tempered glass lens, and pendant mounting configuration.

The fixture operates from -40F to 302F and is suited to locations where standard high bay fixtures may not tolerate sustained heat exposure. Its 50-watt output replaces a 250-watt metal halide fixture.

Core Performance and Output

This fixture produces 7,500 lumens at 150 lumens per watt. The 120-degree beam angle provides a broad distribution from a pendant-mounted position.

It operates on 100-277V, 50/60 Hz power with a power factor above 0.95 and THD below 15%. The 7,500-lumen output can be excessive where mounting height is low or where concentrated task-area lighting is required.

The broad 120-degree distribution supports wider coverage, but uniformity depends on the mounting height and fixture layout. Higher mounting positions may require layout review to maintain light levels between fixtures.

Adjustability and Control Options

This fixture has a fixed 50-watt output and is not dimmable. It operates at a fixed 5000K color temperature with a CRI of 75+.

The standard optic is a tempered glass lens with a 120-degree beam angle. No alternate beam angles or control options are listed for this configuration.

Longevity and Reliability

The LED system is rated for 100,000 hours L70 life. This rating supports long operating intervals in high temperature facility lighting and other heat-exposed industrial areas.

A 6kV surge protection rating is included. The fixture carries a 5-year warranty.

Build Quality and Physical Characteristics

The housing is aluminum alloy with a silver finish. A tempered glass lens protects the optical assembly.

The fixture is IP66 rated and measures 12 x 10.5 x 2.5 inches. It weighs 11 pounds and uses pendant mounting.

Where This Product Fits Best

This fixture fits elevated-temperature industrial areas where the operating environment can reach up to 302F. Its pendant mount, broad beam pattern, and high-temperature operating range align with heat-exposed lighting locations.

  • industrial furnace area lighting
  • power plant and energy site lighting
  • nuclear facility lighting
  • high temperature facility lighting
  • boiler room lighting
  • heat treatment facility lighting
  • kiln lighting

The IP66-rated enclosure and tempered glass lens support use where dust and water ingress protection are required. Final suitability depends on actual ambient temperature at the fixture location and the pendant mounting arrangement.

Installation and Long-Term Use

Pendant mounting requires a suitable overhead mounting point and support for the 11-pound fixture. The installation location must keep the fixture within its stated -40F to 302F operating temperature range.

Verify the available supply voltage is within the listed 100-277V range before installation. The fixture is non-dimmable, so it should be connected only where fixed-output operation is required.

How This Fixture Is Commonly Used

In industrial furnace area lighting, boiler room lighting, and heat treatment facility lighting, fixtures are pendant-mounted below the available overhead structure. Mounting height is established around the heat source, structural conditions, and required light distribution.

Layouts use the 120-degree beam pattern to distribute light across the selected area. Spacing varies with mounting height, target light levels, and the 7,500-lumen output.

For power plant and energy site lighting, nuclear facility lighting, and kiln lighting, fixture placement should account for the measured ambient temperature at the installed location. The 302F maximum operating temperature applies to the fixture environment, not only the nearby process temperature.

Safety, Certifications, and Warranty

This fixture is ETL listed. It is IP66 rated.

The operating temperature range is -40F to 302F. The fixture includes 6kV surge protection and a 5-year warranty.

Frequently Asked Questions

Q: What is the light output of this high temperature fixture?

A: The fixture delivers 7,500 lumens at 50 watts, producing 150 lumens per watt.

Q: What voltage does this fixture operate on?

A: It operates on 100-277V, 50/60 Hz power.

Q: Can this fixture be dimmed?

A: No. This configuration is not dimmable.

Q: What mounting method is provided?

A: The fixture uses pendant mounting.

Q: What should be considered when planning fixture layout?

A: Layout should account for the 7,500-lumen output, 120-degree beam angle, mounting height, and required light levels. The supplied product data does not establish a specific spacing value or fixture quantity.

Application Questions and Clarification

Q: Is this fixture suitable for industrial furnace area lighting?

A: The fixture is rated for operation from -40F to 302F and is listed for industrial furnace area lighting. Actual ambient temperature at the fixture location must remain within the stated operating range.

Q: Can this fixture be used for power plant and energy site lighting?

A: Power plant and energy site lighting is a listed application. Fixture placement must account for pendant mounting and the available 100-277V supply.

Q: What should be confirmed for boiler room lighting?

A: Confirm the ambient temperature at the fixture location, pendant mounting arrangement, supply voltage, and required layout. The fixture is rated to 302F and has a 120-degree beam angle.

Web ID: 2165