200 Watt LED High Temperature Light | 26000 Lumens | 5000K | 100V-277V or 347V-480V | Rated to 194F

SKU: MLLG-LS-LED-HB-200-[Color]-HT-[V] Web ID: 1325
Starting at: $2,063.07

100V-277V:Built to Order 6 Weeks

347V-480V:Built to Order 8 Weeks
This 200W high-temperature LED high bay delivers 26,000 lumens while replacing a 400W metal halide, making it a practical upgrade for facilities seeking lower wattage and long service life. Its IP66 aluminum alloy construction and -40F to 194F operating range suit demanding power plant and nuclear facility environments. Multiple beam angles, 4000K or 5000K options, and eye-hook or pendant mounting help match light distribution and installation needs.

Cory Peterson | VP of Marketing and Sales Operations

Prefer to Order Online? Select Options

Out of stock

Product Specifications

ETL Listed - Certified for Product Safety Compliance to North American StandardsHigh Temperature Rated - Reliable Operation in Elevated Heat Conditions5 Year Unlimited Usage Warranty

Key Features

Brand LED Lighting Supply
Watts 200
Lumens 26000
Lumens Per Watt 130
Replaces 400 Watt Metal Halide
Voltage 100V-277V or 347V-480V
Color Temperature 4000K or 5000K
CRI 80+
Dimming No
Beam Angles (Opt) 10° or 25° or 40° or 90° or 120°
Optics Polycarbonate Lens
Lifespan 70,000 hours
Mounting Eye-Hook or Pendant
Fixture Color Gray
Frequency (Hz) 50/60 hz
Power Factor > .95
THD < 15%

Durable Construction

Housing Aluminum Alloy
IP Rating IP66
Operating Temperature -40°F to 194°F
Certifications ETL
Warranty 5 years

Measurements

Dimensions (in) 18.11 X 14.17 X 8.65
Weight (lbs) 24.6 lbs

Product SKU Variations

  • SKU: MLLG-LS-LED-HB-200-50-90-HT
  • SKU: MLLG-LS-LED-HB-200-50-90-HT-HV

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.20

Product Overview

This 200 watt LED high temperature light is a UFO fixture built for continuous operation in elevated-heat areas. It produces 26,000 lumens and operates in ambient temperatures from -40F to 194F.

The fixture is configured for eye-hook or pendant mounting and uses an aluminum alloy housing with a polycarbonate lens. It replaces a 400 watt metal halide fixture where the existing lighting system and mounting arrangement support the change.

Core Performance and Output

This fixture delivers 26,000 lumens at 130 lumens per watt. Available 4000K and 5000K color temperatures provide options for different visual conditions, while the 80+ CRI supports general industrial visibility.

Available beam angles are 10, 25, 40, 90, and 120 degrees. Narrow optics concentrate output for targeted layouts, while wider optics support broader coverage; a wide beam can create excessive brightness when mounted too close to the work area.

The fixture operates on 100V-277V or 347V-480V, at 50/60 Hz. Power factor is greater than 0.95 and THD is less than 15%.

Adjustability and Control Options

This high temperature light is available in 4000K or 5000K and with five beam angle options. Optic selection should match the mounting position, target area, and required distribution pattern.

The fixture is not dimmable. Voltage must be selected as either 100V-277V or 347V-480V for the installed electrical system.

Longevity and Reliability

The rated lifespan is 70,000 hours. The high temperature operating range supports installations with ambient temperatures up to 194F.

Long-term performance depends on maintaining the fixture within its listed temperature range and keeping the lens and mounting assembly in serviceable condition. This fixture is intended for fixed high-temperature lighting locations rather than dimming-controlled operation.

Build Quality and Physical Characteristics

The gray aluminum alloy housing measures 18.11 x 14.17 x 8.65 inches and weighs 24.6 pounds. The polycarbonate lens protects the optical system.

IP66 construction supports exposure to dust and water intrusion consistent with the rating. Eye-hook and pendant mounting configurations require a mounting point capable of supporting the fixture weight.

Where This Product Fits Best

This fixture fits high temperature facility lighting where elevated ambient heat would limit standard industrial fixtures. Its 194F maximum operating temperature supports demanding fixed-location installations.

  • power plant and energy site lighting
  • industrial furnace area lighting
  • steel mill lighting
  • foundry lighting
  • nuclear facility lighting
  • boiler room lighting

IP66 construction, aluminum alloy housing, and high-temperature operation suit locations with heat, dust, and water exposure. Beam angle selection remains important where mounting positions and illuminated areas vary.

Installation and Long-Term Use

Install the fixture by eye-hook or pendant mounting on a structure that supports its 24.6 pound weight. Verify the selected voltage matches the available 100V-277V or 347V-480V electrical system before energizing the fixture.

Maintain clear access for lens inspection and fixture servicing. Confirm that ambient temperature at the installed location remains within the -40F to 194F operating range.

How This Fixture Is Commonly Used

In power plant and energy site lighting, industrial furnace area lighting, steel mill lighting, and foundry lighting, the fixture is mounted above the target area using an eye-hook or pendant. Layouts use the selected optic to direct light toward the required work or equipment area.

For nuclear facility lighting and boiler room lighting, mounting height and fixture placement follow the available structural locations and required light distribution. Narrower optics concentrate output, while wider optics spread output across a larger area.

Spacing varies with beam angle, mounting height, target light levels, and the layout requirements of the selected application. A higher output concentration can reduce spill outside the target area but may require more careful aiming.

Safety, Certifications, and Warranty

This fixture is ETL listed.

The fixture is IP66 rated and carries a 5-year warranty.

Frequently Asked Questions

Q: What is the output of this high temperature light?

A: This fixture uses 200 watts and produces 26,000 lumens at 130 lumens per watt.

Q: What ambient temperature range is this fixture rated for?

A: The operating temperature range is -40F to 194F.

Q: Is this fixture dimmable?

A: No. This fixture is not dimmable.

Q: What mounting options are available?

A: The available mounting options are eye-hook and pendant mounting.

Q: What should be considered when planning fixture layout?

A: Beam angle, mounting height, target light levels, and the required distribution pattern affect the layout. Available beam angles are 10, 25, 40, 90, and 120 degrees.

Application Questions and Clarification

Q: Is this fixture appropriate for high temperature facility lighting?

A: The fixture is designed for high temperature facility lighting and is rated for ambient temperatures up to 194F.

Q: What should be confirmed for industrial furnace area lighting or boiler room lighting?

A: Confirm the ambient temperature at the fixture location, available voltage, mounting method, and required beam distribution. The fixture operates from -40F to 194F and is available in 100V-277V or 347V-480V versions.

Q: Which optic should be considered for steel mill lighting or foundry lighting?

A: The appropriate optic depends on the mounting position and required distribution pattern. This fixture is available with 10, 25, 40, 90, and 120 degree beam angles.

Web ID: 1325

You may also like