Need help choosing the right fans?
Get expert recommendations and a custom fan plan within 1 day! Get Product Recommendations ➜
24 Foot HVLS Ceiling Fan | 6 Blades | 18,300 Square Foot Coverage | 208-240V or 380-480V
This 24-foot HVLS fan is a strong choice for large industrial and commercial spaces needing high-volume air movement, thanks to its 547,378 CFM output and coverage of up to 18,300 square feet. The IP55 fan and IP66 controller ratings allow reliable operation in environments with dust or water exposure, while the aluminum blades and PMSM motor support long-term, efficient use. The low 38 dB sound level minimizes noise impact, making it suitable for occupied areas. Ideal applications include warehouses, manufacturing floors, distribution centers, and sports venues. Proper structural support and electrical compatibility must be confirmed before installation.
Product Description
Key Features
- Diameter: 24 ft
- Speed: Variable
- Phase: 1P | 3P
- Color: Silver
- Blade Material: Aluminum
- Controller: Wall Mounted VFD
- Blades: 6
- Frequency (hz): 50/60
- Fan CFM: 547,378
- Coverage Area (sq ft): 18,300
- RPM: 60
- Sound Level (db): 38
- Fan Weight (lbs): 345
- Motor Size: 2 HP 1500 Watt | PMSM Motor
- IP Rating: IP55 | Controller IP66
- Downrod (in): 39
- Voltage: 208V-240V | 380V-480V
- Warranty: 2 years
Web ID: 2705
Product Overview
This 24 Foot HVLS Ceiling Fan is engineered for large-scale air movement in commercial and industrial environments. The six-blade design and 24-foot diameter deliver high-volume, low-speed airflow for effective ventilation and occupant comfort. Typical installations include warehouses, manufacturing facilities, and agricultural buildings with high ceilings and open floor plans. The fan operates on either 208-240V or 380-480V, supporting both single and three-phase power systems.
The fan is equipped with a 2 HP PMSM motor and a wall-mounted VFD controller for variable speed operation. The IP55 fan and IP66 controller ratings provide protection against dust and water ingress, supporting use in demanding environments. The 39-inch downrod allows for proper clearance and optimal air distribution in spaces with tall ceilings.
Core Performance and Output
This HVLS fan delivers up to 547,378 CFM, providing coverage for areas up to 18,300 square feet. The variable speed control allows adjustment of airflow to match seasonal and occupancy needs. At maximum output, the fan operates at 60 RPM and maintains a low sound level of 38 dB, minimizing noise impact in occupied spaces.
The 2 HP, 1500W PMSM motor ensures efficient operation and consistent performance. Excessive output may occur in smaller or low-ceiling spaces, so installation is best suited for large, open areas with adequate mounting height. Uniform airflow is maintained across the coverage area, but obstructions or irregular layouts can reduce effectiveness.
Adjustability and Control Options
The fan includes a wall-mounted VFD controller, supporting variable speed operation for precise airflow management. The controller is rated IP66 for protection against dust and water, suitable for industrial and agricultural settings. Speed adjustments can be made to accommodate changes in temperature, occupancy, or process requirements.
Control wiring and integration with building management systems may be possible, depending on site requirements and controller compatibility. The fan supports both 50 Hz and 60 Hz operation, allowing deployment in a range of global electrical environments.
Longevity and Reliability
The fan is constructed with an aluminum blade set and a PMSM motor designed for continuous operation in demanding environments. The IP55 rating protects the motor and electronics from dust and water spray, supporting long-term reliability in industrial and agricultural buildings.
Routine inspection and cleaning of blades and motor housing are recommended to maintain performance. The fan is covered by a 2-year warranty, supporting maintenance planning and operational continuity.
Build Quality and Physical Characteristics
This fan features a 24-foot diameter with six aluminum blades, providing a balance of strength and low weight for efficient operation. The total fan weight is 345 lbs, requiring a structurally sound mounting point. The 39-inch downrod ensures proper clearance from the ceiling and obstructions.
The silver finish and industrial-grade construction are designed for durability in high-traffic and high-dust environments. The fan is suitable for both single-phase and three-phase power supplies, with voltage options of 208-240V or 380-480V. The low sound level supports use in occupied spaces where noise is a concern.
Where This Product Fits Best
This HVLS fan is designed for large, open environments with high ceilings and significant ventilation needs. It is commonly installed in:
- warehouse ventilation
- manufacturing facility ventilation
- gymnasium ventilation
- agricultural building ventilation
- aircraft hangar ventilation
- distribution center ventilation
- convention center ventilation
- large retail ventilation
The fan?s IP55 and IP66 ratings support use in dusty, humid, or partially exposed environments. Adequate ceiling height and structural support are required for safe installation and optimal performance.
Installation and Long-Term Use
Installation requires a secure mounting structure capable of supporting the 345 lb fan and dynamic loads during operation. The 39-inch downrod provides necessary clearance for airflow and safety. Electrical connection supports both 208-240V and 380-480V, single or three-phase, depending on site power availability.
Routine maintenance includes periodic inspection of mounting hardware, blade cleaning, and controller checks. The fan?s low sound output and efficient motor design support continuous operation in occupied spaces. Long-term reliability is supported by robust construction and ingress protection ratings.
How This Fixture Is Commonly Used
Typical mounting heights range from 20 to 40 feet, depending on ceiling structure and clearance requirements. Fans are spaced to provide overlapping coverage, with one unit typically serving up to 18,300 square feet. In larger facilities, multiple fans are installed in a grid pattern to maintain consistent airflow throughout the space.
Variable speed control allows adjustment for seasonal changes or process needs. Higher speeds increase air movement but may require wider spacing to avoid excessive airflow overlap. Layout and spacing should account for obstructions, racking, or equipment that may disrupt airflow patterns.
Safety, Certifications, and Warranty
The fan is rated IP55 for the motor and IP66 for the controller. These ratings provide protection against dust and water ingress. The aluminum blade construction and PMSM motor are designed for industrial use. The fan operates at a low sound level of 38 dB, supporting safe use in occupied environments.
A 2-year warranty is provided. All safety and certification information is stated as supplied by the manufacturer. Installation must comply with local codes and structural requirements.
Frequently Asked Questions
Q: What is the recommended mounting height for this 24-foot HVLS fan?
A: Recommended mounting height is typically 20 to 40 feet, depending on ceiling structure and required clearance.
Q: How much area does this fan effectively cover?
A: The fan is designed to provide airflow coverage for up to 18,300 square feet per unit.
Q: Can this fan be used in environments with high dust or humidity?
A: Yes, the fan is rated IP55 and the controller is rated IP66, supporting use in dusty or humid environments.
Q: What type of power supply is required?
A: The fan supports 208-240V or 380-480V, single-phase or three-phase power, at 50 or 60 Hz.
Q: How loud is the fan during operation?
A: The fan operates at a sound level of 38 dB at maximum speed.
Q: How should I plan fan spacing in a large facility?
A: Spacing is typically based on the 18,300 square foot coverage per fan, with adjustments for obstructions and desired airflow overlap.
Application Questions and Clarification
Q: Is this fan suitable for use in livestock or agricultural buildings?
A: Yes, the fan is commonly installed in agricultural building ventilation and livestock facility ventilation applications.
Q: Can this fan be installed in an aircraft hangar?
A: Yes, the fan is suitable for aircraft hangar ventilation, provided mounting height and structural support requirements are met.
Q: Is the controller protected against water and dust?
A: The wall-mounted VFD controller is rated IP66, providing high protection against dust and water ingress.
Q: What maintenance is required for long-term operation?
A: Routine maintenance includes inspecting mounting hardware, cleaning blades, and checking the controller for proper operation.