Key Features
- Diameter: 24 ft
- Speed: Variable
- Phase: 3P
- Color: Brushed Aluminum | Black | Blue | White
- Blade Material: Aluminum
- Controller: Wall Mounted VFD
- Blades: 8
- AMPs: 208-240V, 3P: 12 A | 460-480V, 3P: 6 A
- Frequency (hz): 60
- Fan CFM: 259,438
- Coverage Area (sq ft): 25,000
- RPM: 62
- Sound Level (db): <59
- Fan Weight (lbs): 262
- Motor Size: 3 HP Gear Drive
- Downrod (in): 1
- Mounting: I-Beam | Z-Purlins | Open Joist
- Voltage: 208V-240V | 460V-480V
- Min Mounting Height: 15 feet
- Min Ceiling Clearance: 6-8 Feet
- Min Horizontal Clearance: 2 Feet
- Warranty: 5 years
The LLS-HVLS-FAN-24FT-8B is a 24 foot diameter 8 blade high volume low speed (HVLS) ceiling fan. It is ideal for industrial-grade and commercial spaces with open floor plans. It includes a NEMA 1 wall-mounted VFD for controlling your unit. The controller features a safety disconnect, on/off toggle, and speed regulator. Safety features include, safety cable, hub clips, hub retainer, dual-method fastening of all joined components, and integrated sprinkler shut-off.
This 24 foot HVLS fan provides huge airflow and comfort. It is perfect for installations in gyms, warehouses, workshops, hangars, manufacturing facilities, and factories.
Web ID: 2327
Product Overview
This 24 Foot HVLS Ceiling Fan is engineered for large-scale air movement in expansive industrial and commercial interiors. With an 8-blade, 24-foot diameter design and a 3 HP gear drive motor, it is built to deliver high-volume, low-speed airflow for occupant comfort and energy efficiency. Typical installations include open floor plan environments such as warehouses, manufacturing plants, and aircraft hangars with mounting heights of 20 feet and above.
The fan includes a NEMA 1 wall-mounted VFD controller for variable speed operation, safety disconnect, and integrated safety features. It is suitable for mounting to I-Beams, Z-Purlins, or open joist structures. Minimum mounting height is 15 feet, with required ceiling and horizontal clearances for safe operation.
Core Performance and Output
This HVLS fan delivers up to 259,438 CFM at a maximum diameter of 24 feet, providing effective coverage for up to 25,000 square feet. The 3 HP motor and 8 aluminum blades are optimized for high-efficiency air movement at low rotational speeds (up to 62 RPM), maintaining sound levels below 59 dB. Variable speed control allows adjustment to match seasonal or occupancy needs.
Performance is consistent across a range of mounting heights, but output may be excessive for spaces under 15 feet or with significant obstructions. Uniform airflow is best achieved in open-plan layouts without dense racking or partitions. At maximum coverage, airflow uniformity may decrease at the perimeter of the coverage area.
Adjustability and Control Options
The included wall-mounted VFD controller provides variable speed adjustment, on/off toggle, and a safety disconnect. Speed can be set to match comfort requirements or energy management strategies. The controller is NEMA 1 rated for indoor use and supports both 208-240V and 460-480V three-phase power.
No integrated network or BMS connectivity is provided as standard. Control is local to the wall station. The fan supports reversible operation only if specified by the manufacturer; default configuration is standard forward airflow.
Longevity and Reliability
The fan is constructed with a 3 HP gear drive motor and aluminum blades for long-term durability in demanding environments. All joined components use dual-method fastening, and safety features include a safety cable, hub clips, hub retainer, and integrated sprinkler shut-off. The fan is designed for continuous operation in industrial settings.
Routine maintenance is limited to periodic inspection of mechanical fasteners and electrical connections. The system is covered by a 5-year warranty. Operating conditions outside recommended voltage or mounting requirements may affect longevity.
Build Quality and Physical Characteristics
The 24-foot diameter fan uses 8 extruded aluminum blades and weighs 262 lbs. Blade finish options include brushed aluminum, black, blue, or white. The downrod is 1 inch in diameter, and the fan requires a minimum ceiling clearance of 6?8 feet and a minimum horizontal clearance of 2 feet from obstructions.
Mounting hardware supports installation on I-Beams, Z-Purlins, or open joists. The fan is suitable for indoor use in dry, non-corrosive environments. Sound output remains below 59 dB at maximum speed, supporting use in occupied spaces.
Where This Product Fits Best
This HVLS fan is designed for large, open-plan industrial and commercial interiors where high-volume air movement is required for occupant comfort and energy efficiency. It is most effective in facilities with high ceilings and minimal obstructions.
- warehouse ventilation
- manufacturing facility ventilation
- aircraft hangar ventilation
- gymnasium ventilation
- distribution center ventilation
- convention center ventilation
- agricultural building ventilation
- large retail ventilation
Best suited for indoor environments with mounting heights above 15 feet and open floor layouts. Not intended for outdoor or corrosive atmospheres. Structural mounting points must support the fan?s weight and dynamic loads.
Installation and Long-Term Use
Installation requires structural mounting to I-Beams, Z-Purlins, or open joists with adequate load capacity. Minimum mounting height is 15 feet, with 6?8 feet of ceiling clearance and at least 2 feet of horizontal clearance from obstructions. Electrical connection supports 208-240V or 460-480V three-phase power.
Routine inspection of mounting hardware, safety cable, and electrical connections is recommended. The fan is designed for continuous operation and minimal maintenance. Access to the wall-mounted VFD controller should be maintained for safe operation and adjustment.
How This Fixture Is Commonly Used
Typical mounting heights range from 20 to 40 feet, depending on ceiling structure and desired airflow. Fans are often spaced to provide overlapping coverage in very large facilities, with one unit covering up to 25,000 square feet. In open-plan layouts, a single fan can serve a large zone, while multiple fans may be used for even air distribution.
Spacing and layout are determined by ceiling height, obstructions, and required comfort levels. Higher output allows for fewer fans, but may increase localized air movement near the fan center. Adjusting speed can help balance comfort and energy use.
Safety, Certifications, and Warranty
This HVLS fan includes integrated safety features: safety cable, hub clips, hub retainer, dual-method fastening, and sprinkler shut-off. The controller is NEMA 1 rated. The fan is designed for compliance with standard industrial safety practices for overhead equipment.
Warranty coverage is 5 years. All installation and operation must follow manufacturer guidelines for safety and performance. No additional third-party certifications are specified.
Frequently Asked Questions
Q: What is the maximum area this fan can effectively cover?
A: The fan is rated for up to 25,000 square feet of open floor space, depending on ceiling height and layout.
Q: What is the minimum mounting height for this fan?
A: Minimum mounting height is 15 feet from the finished floor to the fan blades.
Q: What type of mounting structures are supported?
A: The fan can be mounted to I-Beams, Z-Purlins, or open joist structures with adequate load capacity.
Q: Is the fan speed adjustable?
A: Yes, the included wall-mounted VFD controller allows variable speed adjustment.
Q: How loud is the fan during operation?
A: Maximum sound level is less than 59 dB at full speed.
Q: Can this fan be used in outdoor or corrosive environments?
A: This model is intended for indoor use in dry, non-corrosive environments only.
Q: How should I plan fan spacing in a large facility?
A: Spacing depends on ceiling height, obstructions, and desired airflow; one fan typically covers up to 25,000 square feet, but overlapping coverage may be needed for uniformity in very large or irregular spaces.
Application Questions and Clarification
Q: Is this fan suitable for use in an aircraft hangar?
A: Yes, this fan is commonly installed for aircraft hangar ventilation when mounting height and structure are appropriate.
Q: Can this fan be used in a livestock or agricultural building?
A: Yes, it is suitable for agricultural building ventilation, provided the environment is dry and non-corrosive.
Q: Is this fan appropriate for gymnasium ventilation?
A: Yes, it is frequently used in gymnasiums with sufficient ceiling height and open space.
Q: What are the electrical requirements for installation?
A: The fan operates on 208-240V or 460-480V three-phase power, with a 3 HP motor drawing 12A or 6A depending on voltage.