16 Foot HVLS Ceiling Fan | 5 Blades | 6,400 Square Foot Coverage

SKU: LLS-G-HVLS-FAN-16FT-5B Web ID: 2628
Starting at: $6,831.67

Availability: 2 In Stock Ships 7-14 Days
This 16-foot HVLS ceiling fan is a strong choice for large indoor spaces needing broad, even air movement, thanks to its five aluminum blades and coverage of up to 6,400 square feet. The direct drive PMSM motor ensures efficient, quiet operation below 40 dBA, which is important for occupied environments. Its IP57 rating allows reliable use in areas exposed to dust or occasional water, such as loading docks or washdown zones. I-beam mounting with a 59-inch downrod suits facilities with exposed steel, and variable speed control adapts airflow to seasonal needs. Ideal applications include warehouses, manufacturing floors, distribution centers, and sports venues.

Dwayne Kula | President, CTO and Founder

Product Specifications

Wet Location Rated - Safe for Direct Exposure to MoistureMET Certified - Independent Safety Certification for Electrical Equipment15 Year Unlimited Usage Warranty

Key Features

Brand LED Lighting Supply
Diameter 16 ft
Speed Variable
Phase 1P
Color Black | Silver
Blade Material Aluminum
Controller Wall Mounted VFD with Remote Control
Blades 5
AMPs 2.0 A at 220V
Frequency (hz) 50/60Hz
Coverage Area (sq ft) 6,400
RPM 25-75
Sound Level (db) <40
Fan Weight (lbs) 120
Motor Size 800 Watt PMSM Direct Drive
IP Rating IP57
Downrod (in) 59
Mounting I-Beam Standard
Voltage 208V-240V | 277V-480V Optional
Warranty 15-year mechanical | 5-year motor | 3-year electrical

Product Overview

This 16-foot HVLS ceiling fan is designed to move air across large interior areas with a five-blade aluminum airfoil assembly and an 800W PMSM direct-drive motor. It operates at variable speed from 25 to 75 RPM.

The fan provides up to 6,400 square feet of coverage and uses a standard I-beam mounting arrangement with a 59-inch downrod. It is configured for facilities that need broad air movement from a ceiling-mounted fan rather than localized airflow.

Core Performance and Output

The 800W PMSM direct-drive motor operates on single-phase 208V-240V power at 50/60Hz. A 277V-480V option is available. Current draw is 2.0A at 220V.

Variable speed operation allows the fan to run from 25 to 75 RPM. The 16-foot diameter and five aluminum blades support a coverage area of 6,400 square feet.

Coverage depends on the installed layout, mounting height, obstructions, and required air movement. A single fan may not provide uniform airflow where structural members or equipment interrupt the air path.

Adjustability and Control Options

The fan uses a wall-mounted VFD controller with remote control. The controller provides variable-speed adjustment for changing operating conditions.

Speed can be reduced where lower air movement is required and increased when broader circulation is needed. The controller location should remain accessible to facility personnel after installation.

Longevity and Reliability

The direct-drive PMSM motor eliminates belt-driven components from the fan assembly. This reduces the number of mechanical wear items associated with belt-driven fan systems.

The fan carries a 15-year mechanical warranty, a 5-year motor warranty, and a 3-year electrical warranty. Routine inspection should include the I-beam mounting connection, blade condition, downrod, and electrical connections.

Build Quality and Physical Characteristics

This fan has a 16-foot diameter, five aluminum blades, and a 120-pound fan weight. Available finish colors are black and silver.

The standard mounting configuration is I-beam mounting with a 59-inch downrod. The IP57 rating supports use where the equipment requires protection from dust and water exposure consistent with that rating.

Where This Product Fits Best

This fan fits large facilities that require broad ceiling-mounted air movement across open operational areas. Its 16-foot blade span and 6,400-square-foot coverage area align with larger ventilation zones.

  • warehouse ventilation
  • manufacturing facility ventilation
  • agricultural building ventilation
  • gymnasium ventilation
  • aircraft hangar ventilation
  • distribution center ventilation

I-beam mounting, available 208V-240V operation, and the optional 277V-480V configuration should be confirmed against the building structure and electrical service. Fan clearance and airflow paths need to remain free of structural and operational obstructions.

Installation and Long-Term Use

The fan mounts to an I-beam using the standard mounting configuration and hangs from a 59-inch downrod. The supporting structure must accommodate the 120-pound fan assembly and operating loads.

Installation requires the correct voltage configuration, secure mechanical mounting, and wall-mounted VFD controller placement. The controller and remote control should remain available for speed adjustment and service access.

Long-term maintenance should include checking mounting hardware, blade attachment points, electrical connections, and controller operation. Keep the blades clear of accumulated debris that can affect balance and airflow.

How This Fixture Is Commonly Used

In warehouse ventilation and distribution center ventilation layouts, the fan is positioned over open areas where the 16-foot diameter can move air across a broad zone. Mounting height must provide clearance for the 59-inch downrod, blade diameter, and surrounding structure.

For manufacturing facility ventilation, agricultural building ventilation, gymnasium ventilation, and aircraft hangar ventilation, fan placement is coordinated around roof structure, equipment, and open floor areas. Layouts typically use repeated fan locations when the ventilation area extends beyond the stated 6,400-square-foot coverage area.

Fan spacing varies with the required coverage, mounting height, and obstructions. Higher fan speed increases air movement, while lower speed reduces airflow and operating sound.

Safety, Certifications, and Warranty

This fan is IP57 rated. It operates on single-phase 208V-240V power at 50/60Hz, with 277V-480V available as an option.

The warranty is 15 years for mechanical components, 5 years for the motor, and 3 years for electrical components. Installation must maintain secure I-beam mounting and protected electrical connections.

Frequently Asked Questions

Q: What is the diameter of this HVLS ceiling fan?

A: The fan has a 16-foot diameter.

Q: What area does the fan cover?

A: The stated coverage area is 6,400 square feet.

Q: What voltage does the fan use?

A: The standard voltage is 208V-240V single phase at 50/60Hz. A 277V-480V option is available.

Q: How is fan speed controlled?

A: The fan uses a wall-mounted VFD controller with remote control and operates at variable speed from 25 to 75 RPM.

Application Questions and Clarification

Q: Is this fan suited to warehouse ventilation and manufacturing facility ventilation?

A: Yes. Warehouse ventilation and manufacturing facility ventilation are primary applications for this HVLS fan.

Q: What should be reviewed when planning fan placement?

A: Review the 16-foot blade diameter, 59-inch downrod, 6,400-square-foot coverage area, I-beam mounting location, structural clearance, and airflow obstructions. A specific spacing value is not established by the supplied product data.

Q: Can this fan be used for agricultural building ventilation?

A: Yes. Agricultural building ventilation is a primary application for this HVLS fan.

Q: What mounting arrangement is supplied as standard?

A: The standard mounting arrangement is I-beam mounting with a 59-inch downrod.

Web ID: 2628

You may also like