16 Foot HVLS Ceiling Fan | 5 Blades | 5,400 Square Foot Coverage | 208-240V or 380-480V

SKU: LLS-EC-HVLS-FAN-16FT-5B Web ID: 2709
Starting at: $4,523.72

Built to Order 8 Weeks

This 16-foot HVLS ceiling fan is a strong choice for large commercial and industrial spaces needing reliable, high-volume air movement with minimal noise. Its 353,147 CFM output and 5,400 square foot coverage efficiently address air circulation in warehouses, manufacturing floors, distribution centers, and sports venues. The IP55 fan and IP66 controller ratings support use in dusty or damp environments, while the wall-mounted VFD allows precise speed control to match operational needs. Aluminum blades offer corrosion resistance and reduced weight. Note that installation requires adequate structural support due to the 186 lb weight.

Dwayne Kula | President, CTO and Founder

Product Specifications

ETL Listed - Certified for Product Safety Compliance to North American Standards

Key Features

Brand LED Lighting Supply
Diameter 16 ft
Speed Variable
Phase 1P | 3P
Color Silver
Blade Material Aluminum
Controller Wall Mounted VFD
Blades 5
Frequency (hz) 50/60
Fan CFM 353,147
Coverage Area (sq ft) 5,400
RPM 80
Sound Level (db) 38
Fan Weight (lbs) 186
Motor Size 1 HP 750 Watt | PMSM Motor
IP Rating IP55 | Controller IP66
Downrod (in) 2
Voltage 208V-240V | 380V-480V
Warranty 2 years

Product Overview

This 16-foot HVLS ceiling fan is designed to move high volumes of air across large interior spaces. Its five aluminum blades and 1 HP PMSM motor deliver up to 353,147 CFM at variable speed.

The fan has a 5,400 square foot coverage area and operates from a wall-mounted VFD controller. It is commonly configured for warehouse ventilation and manufacturing facility ventilation where broad, low-speed air movement is required.

Core Performance and Output

The 750-watt, 1 HP PMSM motor drives the fan at speeds up to 80 RPM. Maximum airflow is 353,147 CFM, with speed adjustment available through the wall-mounted VFD controller.

The 16-foot diameter is intended for open areas requiring broad air coverage rather than concentrated airflow. The stated coverage area is 5,400 square feet, but final layout depends on ceiling structure, obstructions, and air movement requirements.

This fan operates on 208V-240V or 380V-480V power at 50/60 Hz. It is available for single-phase or three-phase operation.

Adjustability and Control Options

Variable-speed operation is controlled through the wall-mounted VFD controller. This allows facility personnel to adjust airflow for changing operating conditions.

The controller is rated IP66. Confirm the available voltage and phase before installation, since the fan supports both 208V-240V and 380V-480V configurations.

Longevity and Reliability

The fan uses a PMSM motor rated at 1 HP and 750 watts. The fan housing is rated IP55.

The controller carries an IP66 rating. The product includes a two-year warranty.

Build Quality and Physical Characteristics

This HVLS fan has a 16-foot diameter, five aluminum blades, and a silver finish. Fan weight is 186 pounds.

The supplied downrod dimension is 2 inches. The fan produces a listed sound level of 38 dB.

Where This Product Fits Best

This fan fits large indoor areas where broad air movement is needed across an open floor area. Its diameter, airflow output, and stated coverage area align with large-scale ventilation layouts.

  • warehouse ventilation
  • manufacturing facility ventilation
  • distribution center ventilation
  • aircraft hangar ventilation
  • agricultural building ventilation
  • livestock facility ventilation
  • gymnasium ventilation

The IP55 fan rating and IP66 controller rating support installations where equipment protection ratings are part of the facility requirement. Ceiling structure, clearances, voltage, and phase must be verified before installation.

Installation and Long-Term Use

The 186-pound fan requires a ceiling mounting point capable of supporting the installed equipment. The 16-foot blade sweep also requires clear space around the fan.

Install the wall-mounted VFD controller where it can be accessed for speed adjustment. Verify whether the electrical supply is 208V-240V or 380V-480V and whether the installation uses single-phase or three-phase power.

Long-term operation includes maintaining blade clearance and keeping the controller accessible. Inspect the fan and mounting assembly as part of the facility maintenance program.

How This Fixture Is Commonly Used

In warehouse ventilation and distribution center ventilation layouts, the fan is positioned to move air across broad open areas. Manufacturing facility ventilation layouts also account for equipment locations and overhead obstructions.

In agricultural building ventilation, livestock facility ventilation, aircraft hangar ventilation, and gymnasium ventilation, blade clearance and ceiling structure remain primary layout factors. The 16-foot diameter requires an unobstructed operating area.

Fan placement is based on the 5,400 square foot stated coverage area, mounting conditions, and the required air movement pattern. Higher fan speed increases airflow output and may change air movement across the space.

Safety, Certifications, and Warranty

The fan is rated IP55. The wall-mounted VFD controller is rated IP66.

The fan operates at 50/60 Hz and supports 208V-240V or 380V-480V power. A two-year warranty is included.

Frequently Asked Questions

Q: What is the diameter of this HVLS fan?

A: The fan has a 16-foot diameter.

Q: What airflow does the fan produce?

A: The listed maximum airflow is 353,147 CFM.

Q: Can the fan speed be adjusted?

A: Yes. The fan has variable speed operation through a wall-mounted VFD controller.

Q: What electrical configurations are supported?

A: The fan supports 208V-240V or 380V-480V operation at 50/60 Hz. It is available for single-phase or three-phase power.

Q: What coverage area should be considered during fan layout?

A: The stated coverage area is 5,400 square feet. Final placement also depends on ceiling structure, clearances, obstructions, and required air movement.

Application Questions and Clarification

Q: Is this fan appropriate for warehouse ventilation?

A: The 16-foot diameter, 353,147 CFM maximum airflow, and 5,400 square foot stated coverage area align with warehouse ventilation layouts that require broad air movement.

Q: What should be reviewed for manufacturing facility ventilation?

A: Review ceiling structure, blade clearance, overhead equipment, available voltage, phase, and controller location before finalizing the installation.

Q: Can this fan be considered for agricultural building ventilation or livestock facility ventilation?

A: Agricultural building ventilation and livestock facility ventilation are valid applications. Confirm the installation structure, clear operating area, and electrical configuration for the specific project.

Web ID: 2709