Out of stock
Product Description
UL Specs
- UL 844 Hazardous Locations
- Class I, Division 2, Groups A, B, C, D
- Class II, Division 1, Groups E, F, G
- Class II, Division 2, Groups F, G
- Class III
- UL 1598 Suitable for Wet Locations
- UL 1598A Marine Outside Type
- ABS
Key Features
- Watts: 100
- Lumens: 10000
- Lumens Per Watt: 100
- Replaces: 400 Watt Metal Halide
- Voltage: 120V
- Color Temperature: 5000K
- CRI: 70+
- Dimming: No
- Beam Angles (Std): 120°
- Beam Angles (Opt): 40° or 60° or 90°
- Optics: Tempered Glass Lens
- Lifespan: 50,000 (L70) hours
- Mounting: Yoke or 3/4 in NPT Pendant
- Fixture Color: Gray
- Frequency: 50-60Hz
- Power Factor: >.95
- THD: < 10%
Durable Construction
- Housing: Copper Free Aluminum
- IP Rating: IP66
- IK Rating: IK10
- Surge Protection: 10kV
- Operating Temperature: -40°F to 176°F
- Certifications: ETL | Rebate Eligible
- Warranty: 5 years
Measurements
- Dimensions: 14 in D X 11.3 in H
- Weight: 26 lbs
Product Overview
This 100 watt explosion proof LED fixture delivers 10,000 lumens at 5000K and operates on 120V input. It replaces 400 watt metal halide fixtures while maintaining hazardous location compliance across multiple classifications. The fixture is built with copper-free aluminum housing and a tempered glass lens.
Classified for Class I Division 2 Groups A, B, C, D and Class II Division 1 Groups E, F, G as well as Class II Division 2 Groups F, G and Class III environments. The fixture carries UL 844 listing for hazardous locations, UL 1598 wet location suitability, and UL 1598A marine outside type rating with ABS certification.
Physical dimensions are 14 inches in diameter by 11.3 inches in height with a weight of 26 pounds. The standard beam angle is 120 degrees with optional 40, 60, or 90 degree optics available. Mounting is supported via yoke or 3/4 inch NPT pendant.
Where This Product Fits Best
This fixture is designed for hazardous environments where combustible gases, vapors, dusts, or fibers may be present. The Class I Division 2 rating covers areas where flammable gases or vapors are handled but not normally present in ignitable concentrations during normal operations. Class II Division 1 and Division 2 ratings address combustible dust environments.
The extended operating temperature range from -40°F to 176°F makes this fixture suitable for heat-intensive industrial processes and extreme cold storage applications. Facilities operating near the upper temperature threshold should verify ambient conditions remain within the rated range during peak operational periods.
Wet location suitability and marine outside type ratings extend application to outdoor industrial sites, waterfront facilities, and marine vessels. The ABS certification supports marine and offshore installations requiring third-party vessel classification.
Performance and Functional Considerations
The fixture produces 100 lumens per watt at 10,000 total lumens output. Color rendering index is 70+ at 5000K color temperature, which provides functional visibility for industrial tasks without the color accuracy required for inspection or color-matching work.
This is a non-dimming fixture operating at fixed 100 watt output. Facilities requiring variable light levels or integration with building automation systems should confirm this fixed-output configuration meets operational requirements before specifying.
Electrical characteristics include power factor greater than 0.95 and total harmonic distortion under 10 percent at 50-60Hz frequency. The 120V single-voltage input requires verification of available service voltage before installation in facilities with 208V, 240V, 277V, or 480V distribution.
Installation and Long-Term Use
Mounting options include yoke mounting for surface or structure attachment and 3/4 inch NPT pendant mounting for suspended installation. The 26-pound fixture weight requires mounting hardware and structural support rated for this load plus any additional forces from vibration or environmental exposure.
IP66 ingress protection allows the fixture to withstand high-pressure water jets and complete dust exclusion. IK10 impact rating provides resistance to physical contact equivalent to heavy tool impacts. The 10kV surge protection addresses transient voltage events common in industrial electrical environments.
Rated lifespan is 50,000 hours at L70, meaning the fixture will maintain at least 70 percent of initial lumen output at that point. The copper-free aluminum housing and tempered glass lens construction support long-term operation in corrosive and physically demanding environments.
How This Fixture Is Commonly Used
Once installed, this fixture operates at fixed output with no field-adjustable wattage or dimming capability. Day-to-day operation is straightforward with the fixture energizing to full output when powered. Facilities relying on this fixture in hazardous areas can expect consistent light levels without the warm-up time associated with the 400 watt metal halide systems it replaces.
The optional beam angles allow configuration at the time of specification to match ceiling height and coverage requirements. The 120-degree standard optic spreads light across wide areas while the narrower 40, 60, and 90-degree options concentrate output for higher mounting heights or task-specific illumination.
In high-temperature environments approaching the 176°F upper limit, the fixture is designed to continue operating without thermal shutdown or accelerated degradation. Maintenance personnel should be aware of the fixture weight when planning lamp or fixture replacement compared to lighter non-explosion-proof alternatives.
Safety, Certifications, and Warranty
This fixture is ETL listed and rebate eligible. UL 844 listing covers hazardous location classifications including Class I Division 2, Class II Division 1 and Division 2, and Class III environments. UL 1598 confirms wet location suitability and UL 1598A confirms marine outside type rating.
ABS certification supports installations on vessels and offshore structures where classification society approval is required. All hazardous location ratings are specific to the groups listed and do not extend to unlisted gas, vapor, or dust classifications.
We provide a 5-year warranty on this fixture.
Frequently Asked Questions
What voltage does this fixture require?
This fixture operates on 120V at 50-60Hz only. It is not multi-voltage and cannot be connected to 208V, 240V, 277V, or 480V circuits.
What hazardous location classifications does this fixture cover?
Class I Division 2 Groups A, B, C, D for flammable gases and vapors. Class II Division 1 Groups E, F, G and Class II Division 2 Groups F, G for combustible dusts. Class III for fibers and flyings.
Is this fixture eligible for utility rebates?
Yes. The fixture is listed as rebate eligible.
What is the maximum ambient operating temperature?
The fixture is rated for operation from -40°F to 176°F.
Can this fixture be dimmed?
No. This is a fixed-output, non-dimming fixture.
What warranty coverage is provided?
This fixture includes a 5-year warranty.
Application Questions and Clarification
This product description reflects the provided specifications, ratings, and configuration options. For questions related to site-specific conditions, electrical compatibility, control integration, or application requirements not addressed in the provided data, our team is available to provide clarification.