Skip to content

150 Watt Round Explosion Proof LED Light | 21000 Lumens | Class 1 Div 1 | 5000K | 100V-277V or 277V-480V

SKU: MLLG-E-LED-EXPLC-150-50-[V]-C1D1 Web ID: 1777
Starting at: $1,120.00
100V-277V:349 In StockShips 3-5 Days
277V-480V:Out of Stock
This 150W fixture delivers 21,000 lumens with a 120 degree beam for hazardous-location and paint booth lighting. Its UL 844 Class I, II, and III ratings, ATEX and IECEx markings support use in specified gas, dust, and fiber hazard classifications. IP66, IK10 construction, 10kV surge protection, and -22F to 122F operation suit demanding wet, marine outside-type, and industrial environments. Yoke or 3/4 in NPT pendant mounting adds installation flexibility.

Cory Peterson | VP of Marketing and Sales Operations

Prefer to Order Online? Select Options

    Product total

    Options total

    Sub-Total

    Product Specifications

    ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsClass 1 Division 1 - UL844 Certified for Hazardous Locations5 Year Unlimited Usage Warranty

    UL Specs

    • UL 844 Hazardous Locations
    • Class I, Division 1, Groups C,D
    • Class I, Division 2, Groups A, B, C, D
    • Class II, Division 1, Groups E, F, G
    • Class II, Division 2, Groups F, G
    • Class III
    • UL 1598 Suitable for Wet Locations
    • UL 1598A Marine Outside Type
    • ABS

    ATEX Marking

    • II 2 G D
    • Ex db IIB T6...T3 Gb
    • Ex tb IIIC T80°C...T195°C Db

    IECEx Marking

    • Ex db IIB T6...T3 Gb
    • Ex tb IIIC T80°C...T195°C Db

    Key Features

    BrandLED Lighting Supply
    Watts150
    Lumens21000
    Lumens Per Watt140
    Replaces400 Watt Metal Halide
    Voltage100V-277V or 277V-480V
    Color Temperature5000K
    CRI70+
    Dimming1-10V
    Beam Angles (Std)120°
    OpticsTempered Glass Lens
    Lifespan50,000 (L70) hours
    MountingYoke or 3/4 in NPT Pendant
    Fixture ColorGray
    Frequency (Hz)50-60Hz
    Power Factor>.95
    THD< 10%

    Durable Construction

    HousingCopper Free Aluminum
    IP RatingIP66
    IK RatingIK10
    Surge Protection10kV
    Operating Temperature-22°F to 122°F
    CertificationsETL | Rebate Eligible
    Warranty5 years

    Measurements

    Dimensions (in)16 X 13.5
    Weight (lbs)39

    Product SKU Variations

    • SKU: MLLG-E-LED-EXPLC-150-50-C1D1
    • SKU: MLLG-E-LED-EXPLC-150-50-HV-C1D1

    Product Lighting Layout Estimator

    Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

    Project Inputs

    Loading fixture information...

    Estimated Results

    Fixtures --
    Layout --
    Estimated Avg FC --
    Approx. Spacing --
    Fixture Offset --
    Calculation Method: --
    Top-Down Fixture Layout Fixture positions and estimated floor light levels
    Lower estimated FC Near target Higher estimated FC

    Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

    Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

    Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

    Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

    Need Verified Light Levels?

    This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

    Estimator Version 2.9.21

    Product Overview

    This 150-watt round explosion proof LED light is a hazardous-location fixture with 21,000 lumens of 5000K light output. It is configured for Class I, II, and III hazardous locations within its listed classifications.

    The fixture replaces a 400-watt metal halide system and uses a copper-free aluminum housing, tempered glass lens, and sealed IP66 construction. Yoke and 3/4 in NPT pendant mounting support common fixed mounting arrangements.

    Core Performance and Output

    The fixture produces 21,000 lumens at 150 watts for 140 lumens per watt. Its 5000K color temperature and 70+ CRI provide a cool white output for hazardous location lighting and paint booth lighting.

    A standard 120-degree beam angle provides broad downward distribution. At lower mounting heights, this output can be excessive without a layout matched to the area. At higher mounting heights, uniformity depends on fixture placement and the required light level.

    The fixture operates on either 100V-277V or 277V-480V at 50-60Hz. Power factor is greater than 0.95, and total harmonic distortion is less than 10%.

    Adjustability and Control Options

    This fixture supports 1-10V dimming. Control wiring and dimming compatibility need to match the installed control system.

    The light output is fixed at 150 watts and 21,000 lumens. The standard optical distribution is 120 degrees.

    Longevity and Reliability

    Rated life is 50,000 hours at L70. The fixture includes 10kV surge protection.

    The operating temperature range is -22 degrees F to 122 degrees F. Long-term performance depends on maintaining the sealed enclosure, electrical connections, and mounting hardware.

    Build Quality and Physical Characteristics

    The gray housing is copper-free aluminum with a tempered glass lens. The fixture is IP66 rated and IK10 rated.

    Fixture dimensions are 16 x 13.5 inches, and weight is 39 pounds. The mounting structure must support the fixture weight and the selected yoke or 3/4 in NPT pendant arrangement.

    Where This Product Fits Best

    This fixture fits classified locations where the listed hazardous-location ratings, wet-location suitability, and sealed construction match site conditions. Its 21,000-lumen output is suited to larger work areas requiring broad overhead distribution.

    • hazardous location lighting
    • paint booth lighting
    • chemical processing facility lighting
    • explosion proof lighting
    • oil and gas facility lighting
    • refinery lighting
    • solvent storage area lighting

    The fixture is rated for wet locations and marine outside type use. Application fit must remain within the listed Class, Division, Group, ATEX, and IECEx markings.

    Installation and Long-Term Use

    Install the fixture using the yoke or 3/4 in NPT pendant mount. The 39-pound fixture weight, mounting orientation, and wiring method need to be addressed before installation.

    Select the 100V-277V or 277V-480V configuration to match the available supply voltage. Hazardous-location installation must follow the applicable electrical requirements and the fixture’s listed classifications.

    How This Fixture Is Commonly Used

    In hazardous location lighting and chemical processing facility lighting, the fixture is mounted overhead using the selected yoke or pendant method. Mounting height is determined by the facility layout, target light level, and required equipment clearance.

    Paint booth lighting and refinery lighting layouts typically use the 120-degree distribution to create broad coverage across the defined work area. Spacing varies with mounting height, required light levels, and the need to control overlap between fixtures.

    For oil and gas facility lighting and solvent storage area lighting, fixture placement must align with the applicable classified area boundaries and the listed fixture classification.

    Safety, Certifications, and Warranty

    UL 844 Hazardous Locations. UL 1598 Suitable for Wet Locations. UL 1598A Marine Outside Type. ABS. ETL. ATEX. IECEx.

    Class I, Division 1, Groups C and D. Class I, Division 2, Groups A, B, C, and D. Class II, Division 1, Groups E, F, and G. Class II, Division 2, Groups F and G. Class III. Warranty is 5 years.

    Frequently Asked Questions

    Q: What is the light output of this explosion proof fixture?

    A: The fixture produces 21,000 lumens at 150 watts, with an efficacy of 140 lumens per watt.

    Q: What voltage configurations are available?

    A: The fixture is available in 100V-277V or 277V-480V configurations.

    Q: Does this fixture support dimming?

    A: Yes. It supports 1-10V dimming.

    Q: What mounting options are provided?

    A: The fixture mounts with a yoke or a 3/4 in NPT pendant mount.

    Q: What planning information is provided for fixture layout?

    A: The product data provides 21,000 lumens, a 120-degree beam angle, and fixture dimensions. It does not establish a fixture spacing value, mounting height, or fixture quantity.

    Application Questions and Clarification

    Q: Is this fixture listed for paint booth lighting?

    A: Paint booth lighting is a listed primary application. Final application fit must align with the fixture’s listed hazardous-location classifications.

    Q: Can this fixture be used for marine environment lighting?

    A: Marine environment lighting is a listed secondary application. The fixture is UL 1598A Marine Outside Type and IP66 rated.

    Q: What should be confirmed for chemical processing facility lighting?

    A: Confirm the available voltage, mounting method, classified area requirements, and required light level. The fixture is available in 100V-277V or 277V-480V configurations with yoke or 3/4 in NPT pendant mounting.

    Web ID: 1777

    You may also like