Skip to content

3 Watt Explosion Proof Exit Emergency LED Light | Class 1 Div 1

SKU: MLLG-E-LED-EXPLJ-3-50-C1D1 Web ID: 1766
Starting at: $1,867.40
Built to Order 6 Weeks
This 3W emergency LED light is a practical choice for hazardous and marine environments requiring UL-listed emergency lighting. Its Class I, II, and III hazardous-location ratings, IP66 wet-location protection, IK10 impact rating, and -40F to 140F operating range support demanding installations. Aluminum alloy construction, tempered glass lens, and 50,000-hour L70 life add durability, while chain-cable or 3/4 in NPT pendant mounting provides installation flexibility.

Dwayne Kula | President, CTO and Founder

Product Specifications

ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsClass 1 Division 1 - UL844 Certified for Hazardous Locations5 Year Unlimited Usage Warranty

UL Specs

  • UL 844 Hazardous Locations
  • Class I, Division 1, Groups C, D
  • Class I, Division 2, Groups A, B, C, D
  • Class II, Division 1, Groups E, F, G
  • Class II, Division 2, Groups F, G
  • Class III
  • UL 924 Emergency Lighting
  • UL 1598A Marine Outside Type
  • UL 1598 Wet Locations
  • UL 8750 LED Safety

Key Features

BrandLED Lighting Supply
Watts3
Voltage100V-277V
DimmingNo
OpticsTempered Glass Lens
Lifespan50,000 (L70) hours
MountingChain-Cable or 3/4 in NPT Pendant
Frequency (Hz)50-60Hz
Power Factor>.95
THD< 10%

Durable Construction

HousingAluminum Alloy
IP RatingIP66
IK RatingIK10
Operating Temperature-40°F to 140°F
CertificationsETL | Rebate Eligible
Warranty5 years

Measurements

Dimensions (in)16 X 11.7
Weight (lbs)14

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.21

Product Overview

This 3 watt explosion proof emergency LED light is built for hazardous location emergency lighting where a sealed, impact-resistant enclosure is required. It operates on 100-277V input and uses a tempered glass lens with an aluminum alloy housing.

The fixture is rated for Class I, II, and III hazardous locations as listed in its UL specifications. Chain-cable and 3/4 in NPT pendant mounting support suspended installation layouts.

Core Performance and Output

This fixture operates at 3 watts on 100-277V, 50-60Hz power. Power factor is greater than 0.95 and total harmonic distortion is less than 10%.

The tempered glass lens protects the LED assembly. Output is intended for emergency lighting duties rather than general hazardous location illumination.

Mounting height and fixture placement need to match the required emergency lighting layout. The supplied product data does not establish spacing, coverage, or fixture quantity.

Adjustability and Control Options

This fixture is non-dimming. It operates across a 100-277V input range.

No optical adjustment or control compatibility is specified. Fixture placement should be determined before installation because the tempered glass lens is a fixed component.

Longevity and Reliability

Rated LED life is 50,000 L70 hours. The operating temperature range is -40 degrees F to 140 degrees F.

The aluminum alloy housing, IP66 rating, and IK10 impact rating support use where moisture, dust, and physical exposure are present. Long-term performance also depends on maintaining the integrity of the mounting and electrical connections.

Build Quality and Physical Characteristics

The housing is aluminum alloy with a tempered glass lens. The fixture measures 16 x 11.7 inches and weighs 14 pounds.

IP66 and IK10 ratings are provided. Chain-cable and 3/4 in NPT pendant mounting are available.

Where This Product Fits Best

This fixture fits hazardous and classified environments requiring emergency lighting equipment with the listed Class I, Class II, and Class III ratings. It is also suited to wet and marine outside type locations covered by its certifications.

  • hazardous location lighting
  • explosion proof lighting
  • chemical processing facility lighting
  • paint booth lighting
  • oil and gas facility lighting
  • marine environment lighting

Its IP66 enclosure, aluminum alloy housing, tempered glass lens, and -40 degrees F to 140 degrees F operating range support exposed industrial conditions. Application fit must remain within the fixture’s listed hazardous location classifications.

Installation and Long-Term Use

Install the fixture using the chain-cable or 3/4 in NPT pendant mounting method specified for the project. The 14 pound fixture weight must be considered when preparing the support structure.

Verify the available voltage is within the 100-277V range. Electrical and mounting work must maintain the enclosure integrity required for the installed environment.

How This Fixture Is Commonly Used

In hazardous location lighting and explosion proof lighting layouts, this fixture is mounted where pendant or chain-cable suspension is appropriate. Mounting height is determined by the facility layout and emergency lighting requirements.

For chemical processing facility lighting, paint booth lighting, oil and gas facility lighting, and marine environment lighting, placement is coordinated with the required emergency lighting layout and the available mounting structure. Fixture spacing varies by the project lighting plan because no coverage or spacing values are supplied.

Safety, Certifications, and Warranty

UL 844 Hazardous Locations. UL 924 Emergency Lighting. UL 1598A Marine Outside Type. UL 1598 Wet Locations. UL 8750 LED Safety.

Class I, Division 1, Groups C and D. Class I, Division 2, Groups A, B, C, and D. Class II, Division 1, Groups E, F, and G. Class II, Division 2, Groups F and G. Class III.

ETL. Rebate Eligible. IP66. IK10. Warranty: 5 years.

Frequently Asked Questions

Q: What input voltage does this explosion proof emergency LED light use?

A: The fixture operates on 100-277V input power at 50-60Hz.

Q: Is this fixture dimmable?

A: No. This fixture is non-dimming.

Q: What mounting methods are available?

A: The fixture supports chain-cable mounting or 3/4 in NPT pendant mounting.

Q: What hazardous location classifications are listed?

A: The fixture is listed for Class I, Division 1, Groups C and D; Class I, Division 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; and Class III.

Application Questions and Clarification

Q: Can this fixture be used for chemical processing facility lighting?

A: Chemical processing facility lighting is a valid application. The installed location must match one of the fixture’s listed hazardous location classifications.

Q: What should be reviewed when planning fixture placement for hazardous location lighting?

A: Review mounting height, mounting structure, voltage, required emergency lighting layout, and the hazardous location classification. The supplied data does not establish fixture spacing or coverage values.

Web ID: 1766