Skip to content

80 Watt Round Explosion Proof LED Light | 11200 Lumens | Class 1 Div 1 | 5000K | 100-277V or 277-480V

SKU: MLLG-E-LED-EXPLC-80-50-[V]-C1D1 Web ID: 1746
Starting at: $800.00
100V-277V:151 In StockShips 3-5 Days
277V-480V:Built to Order 6 Weeks

Lighting a large indoor space?

Get a free lighting plan and volume pricing to ensure uniform illumination without overbuying fixtures.

Get Contractor or Bulk Pricing

Get your quote within 1 hour!

Call to Order: (888) 423-3191
This 80W, 11,200-lumen fixture is a practical 250W metal halide replacement for hazardous locations and paint booths. Its UL 844 Class I, II and III ratings, ATEX and IECEx markings support use where combustible gases, dusts or fibers are present. IP66, IK10 construction, 10kV surge protection, marine suitability, and a -22F to 122F operating range suit demanding industrial environments. Yoke or 3/4 in NPT pendant mounting provides installation flexibility.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

    Product total

    Options total

    Sub-Total

    Product Specifications

    ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsClass 1 Division 1 - UL844 Certified for Hazardous Locations5 Year Unlimited Usage Warranty

    UL Specs

    • UL 844 Hazardous Locations
    • Class I, Division 1, Groups C,D
    • Class I, Division 2, Groups A, B, C, D
    • Class II, Division 1, Groups E, F, G
    • Class II, Division 2, Groups F, G
    • Class III
    • UL 1598 Suitable for Wet Locations
    • UL 1598A Marine Outside Type
    • ABS

    ATEX Marking

    • II 2 G D
    • Ex db IIB T6...T3 Gb
    • Ex tb IIIC T80°C...T195°C Db

    IECEx Marking

    • Ex db IIB T6...T3 Gb
    • Ex tb IIIC T80°C...T195°C Db

    Key Features

    BrandLED Lighting Supply
    Watts80
    Lumens11200
    Lumens Per Watt140
    Replaces250 Watt Metal Halide
    Voltage100V-277V or 277V-480V
    Color Temperature5000K
    CRI70+
    Dimming1-10V
    Beam Angles (Std)120°
    OpticsTempered Glass Lens
    Lifespan50,000 (L70) hours
    MountingYoke or 3/4 in NPT Pendant
    Fixture ColorGray
    Frequency (Hz)50-60Hz
    Power Factor>.95
    THD< 10%

    Durable Construction

    HousingCopper Free Aluminum
    IP RatingIP66
    IK RatingIK10
    Surge Protection10kV
    Operating Temperature-22°F to 122°F
    CertificationsETL | Rebate Eligible
    Warranty5 years

    Measurements

    Dimensions (in)16 D x 13.5 H
    Weight (lbs)39

    Notes

    • Class l, Zone 1, Group llB plus hydrogen
    • Class l, Zone 2, Group llB plus hydrogen
    • Zone 20 and Zone 21
    • Zone 22

    Product SKU Variations

    • SKU: MLLG-E-LED-EXPLC-80-50-C1D1
    • SKU: MLLG-E-LED-EXPLC-80-50-HV-C1D1

    Product Lighting Layout Estimator

    Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

    Project Inputs

    Loading fixture information...

    Estimated Results

    Fixtures --
    Layout --
    Estimated Avg FC --
    Approx. Spacing --
    Fixture Offset --
    Calculation Method: --
    Top-Down Fixture Layout Fixture positions and estimated floor light levels
    Lower estimated FC Near target Higher estimated FC

    Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

    Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

    Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

    Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

    Need Verified Light Levels?

    This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

    Estimator Version 2.9.21

    Product Overview

    This 80 watt round LED explosion proof light delivers 11,200 lumens at 5000K for hazardous location lighting. It is available in 100-277V or 277-480V configurations and provides 1-10V dimming capability.

    The fixture uses a 120-degree beam distribution, tempered glass lens, and copper-free aluminum housing. It is an LED replacement option for 250 watt metal halide fixtures.

    Core Performance and Output

    With 140 lumens per watt, this fixture provides high-output illumination from an 80 watt LED system. The 5000K color temperature and 70+ CRI support clear visibility in industrial hazardous locations.

    The fixture operates on 50-60Hz power, has a power factor greater than 0.95, and THD below 10%.

    Build Quality and Physical Characteristics

    The gray copper-free aluminum housing is rated IP66 and IK10. A tempered glass lens protects the optical assembly, while 10kV surge protection supports the fixture’s electrical durability.

    This round fixture measures 16 inches in diameter by 13.5 inches high and weighs 39 pounds.

    Where This Product Fits Best

    This fixture is designed for classified hazardous locations where its listed Class, Division, and Group ratings match the installation requirements.

    • hazardous location lighting
    • explosion proof lighting
    • paint booth lighting
    • chemical processing facility lighting
    • oil and gas facility lighting
    • refinery lighting
    • marine environment lighting
    • offshore rig lighting

    Installation and Long-Term Use

    The fixture mounts by yoke or 3/4 in NPT pendant mounting. Select the required 100-277V or 277-480V fixture configuration for the available electrical system.

    Rated operating temperature is -22 degrees F to 122 degrees F. The LED system is rated for 50,000 L70 hours.

    Safety, Certifications, and Warranty

    This fixture is rated UL 844 Hazardous Locations, UL 1598 Suitable for Wet Locations, UL 1598A Marine Outside Type, and ABS. It carries ATEX and IECEx markings of Ex db IIB T6…T3 Gb and Ex tb IIIC T80°C…T195°C Db.

    UL hazardous location classifications include Class I, Division 1, Groups C and D; Class I, Division 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; and Class III. The fixture includes a 5-year warranty.

    Frequently Asked Questions

    Q: What mounting options are available for this 80 watt explosion proof light?

    A: This 80 watt round explosion proof LED light can be mounted with a yoke or a 3/4 in NPT pendant mount.

    Q: Is this explosion proof fixture available for 277-480V power?

    A: Yes. This explosion proof LED light is available in either 100-277V or 277-480V configurations.

    Web ID: 1746

    You may also like