Skip to content

15+ Years of Lighting Commercial, Industrial, and Sports Projects

200 Watt Square Explosion Proof LED Light | 28000 Lumens | Class 1 Div 2 | 5000K | 100V-277V or 277V-480V

SKU: MLLG-E-LED-EXPLA-200-50-[V]-C1D2 Web ID: 1519
Starting at: $790.00
100V-277V:424 In StockShips 3-5 Days
277V-480V:Built to Order 6 Weeks
This 200W hazardous-location LED fixture is well suited to paint booths and classified industrial areas, delivering 28,000 lumens at 140 lm/W as a 400W metal halide replacement. Its UL 844 Class I, II, and III listings, ATEX and IECEx markings support use in specified hazardous environments. IP66, IK10, 10kV surge protection, and -40F to 122F operation address demanding conditions, while yoke or 3/4 in NPT pendant mounting and selectable optics help match installation needs.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

    Product total

    Options total

    Sub-Total

    Product Specifications

    ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsClass 1 Division 2 - UL844 Certified for Explosive Atmospheres5 Year Unlimited Usage Warranty

    UL Specs

    • UL 844 Hazardous Locations
    • Class I, Division 2, Groups A, B, C, D
    • Class II, Division 1, Groups E, F, G
    • Class II, Division 2, Groups F, G
    • Class III
    • UL 1598 Suitable for Wet Locations
    • UL 1598A Marine Outside Type
    • ABS

    ATEX Marking

    • II 2 G Ex eb mb IIC T5...T6 Gb
    • II 2 D Ex tb IIIC T80°C...T100°C Db

    IECEx Marking

    • Ex eb mb IIC T5...T6 Gb
    • Ex tb IIIC T80°C...T100°C Db

    Key Features

    BrandLED Lighting Supply
    Watts200
    Lumens28000
    Lumens Per Watt140
    Replaces400 Watt Metal Halide
    Voltage100V-277V or 277V-480V
    Color Temperature5000K
    CRI70+
    Dimming1-10V
    Beam Angles (Std)120°
    Beam Angles (Opt)40° or 60° or 90°
    OpticsTempered Glass Lens
    Lifespan50,000 (L70) hours
    MountingYoke or 3/4 in NPT Pendant
    Fixture ColorGray
    Frequency (Hz)50-60Hz
    Power Factor>.95
    THD< 10%

    Durable Construction

    HousingCopper Free Aluminum
    IP RatingIP66
    IK RatingIK10
    Surge Protection10kV
    Operating Temperature-40°F to 122°F
    CertificationsETL | Rebate Eligible
    Warranty5 years

    Measurements

    Dimensions (in)19 X 9 X 7.4
    Weight (lbs)26

    Product SKU Variations

    • SKU: MLLG-E-LED-EXPLA-200-50-C1D2
    • SKU: MLLG-E-LED-EXPLA-200-50-HV-C1D2

    Product Lighting Layout Estimator

    Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

    Project Inputs

    Loading fixture information...

    Estimated Results

    Fixtures --
    Layout --
    Estimated Avg FC --
    Approx. Spacing --
    Fixture Offset --
    Calculation Method: --
    Top-Down Fixture Layout Fixture positions and estimated floor light levels
    Lower estimated FC Near target Higher estimated FC

    Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

    Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

    Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

    Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

    Need Verified Light Levels?

    This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

    Estimator Version 2.9.21

    Product Overview

    This 200 Watt square LED explosion proof high bay delivers 28,000 lumens at 5000K for hazardous location lighting. It is available in 100V-277V or 277V-480V configurations and can replace a 400 Watt metal halide fixture.

    Core Performance and Output

    The fixture produces 140 lumens per watt with a standard 120 degree beam angle. Optional 40 degree, 60 degree, and 90 degree beam angles provide narrower distribution choices for layouts that require more directed light.

    It has a 70+ CRI, 1-10V dimming, power factor greater than .95, and THD below 10%.

    Longevity and Reliability

    The LED system is rated for 50,000 L70 hours and operates from -40 degrees F to 122 degrees F. A 10kV surge protection rating supports electrical protection in demanding installations.

    Build Quality and Physical Characteristics

    The gray copper-free aluminum housing uses a tempered glass lens. IP66 and IK10 ratings address ingress protection and impact resistance.

    This fixture measures 19 x 9 x 7.4 inches and weighs 26 pounds.

    Where This Product Fits Best

    This fixture is intended for hazardous location lighting where its Class I, II, and III classifications and explosion protection markings match project requirements.

    • hazardous location lighting
    • explosion proof lighting
    • paint booth lighting
    • chemical processing facility lighting
    • oil and gas facility lighting
    • refinery lighting
    • marine environment lighting
    • wastewater treatment lighting

    Installation and Long-Term Use

    Mounting options include a yoke mount or 3/4 in NPT pendant mount. Select the voltage configuration and mounting method that match the installation.

    Safety, Certifications, and Warranty

    The fixture is UL 844 rated for Class I, Division 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; and Class III locations. It is also UL 1598 suitable for wet locations, UL 1598A Marine Outside Type, ABS, ATEX, IECEx, and ETL certified.

    ATEX marking: II 2 G Ex eb mb IIC T5…T6 Gb and II 2 D Ex tb IIIC T80°C…T100°C Db. IECEx marking: Ex eb mb IIC T5…T6 Gb and Ex tb IIIC T80°C…T100°C Db. The fixture carries a 5-year warranty.

    Frequently Asked Questions

    Q: What voltage options are available for this 200 Watt explosion proof light?

    A: This 200 Watt explosion proof LED light is available in either 100V-277V or 277V-480V configurations.

    Q: What mounting options are available?

    A: This square explosion proof LED light can be mounted with a yoke mount or a 3/4 in NPT pendant mount.

    Q: Can the beam angle be changed?

    A: This fixture has a standard 120 degree beam angle, with optional 40 degree, 60 degree, and 90 degree beam angles.

    Web ID: 1519

    You may also like