Skip to content

80 Watt Square Explosion Proof LED Light | 11200 Lumens | Class 1 Div 2 | 5000K | 100V-277V or 277V-480V

SKU: MLLG-E-LED-EXPLA-80-50-[V]-C1D2 Web ID: 1541
Starting at: $580.00
100V-277V:201 In StockShips 3-5 Days
277V-480V:Built to Order 6 Weeks

This 80W square explosion-proof LED is a practical choice for hazardous locations needing 11,200 lumens, 5000K light, and 140 lm/W efficiency. Its UL hazardous-location classifications, ATEX and IECEx markings support use in qualifying industrial areas, while IP66, IK10 construction, 10kV surge protection, and wet and marine ratings suit demanding environments. Yoke or 3/4 in NPT pendant mounting and selectable optics make it well suited to paint booths, industrial facilities, and marine applications.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

    Product total

    Options total

    Sub-Total

    Product Specifications

    ETL Listed - Certified for Product Safety Compliance to North American StandardsRebate Eligible - Qualifies for Energy Incentive ProgramsClass 1 Division 2 - UL844 Certified for Explosive Atmospheres5 Year Unlimited Usage Warranty

    UL Specs

    • UL 844 Hazardous Locations
    • Class I, Division 2, Groups A, B, C, D
    • Class II, Division 1, Groups E, F, G
    • Class II, Division 2, Groups F, G
    • Class III
    • UL 1598 Suitable for Wet Locations
    • UL 1598A Marine Outside Type
    • ABS

    ATEX Marking

    • II 2 G Ex eb mb IIC T5...T6 Gb
    • II 2 D Ex tb IIIC T80°C...T100°C Db

    IECEx Marking

    • Ex eb mb IIC T5...T6 Gb
    • Ex tb IIIC T80°C...T100°C Db

    Key Features

    BrandLED Lighting Supply
    Watts80
    Lumens11200
    Lumens Per Watt140
    Replaces250 Watt Metal Halide
    Voltage100V-277V or 277V-480V
    Color Temperature5000K
    CRI70+
    Dimming1-10V
    Beam Angles (Std)120°
    Beam Angles (Opt)40° or 60° or 90°
    OpticsTempered Glass Lens
    Lifespan50,000 (L70) hours
    MountingYoke or 3/4 in NPT Pendant
    Fixture ColorGray
    Frequency (Hz)50-60Hz
    Power Factor>.95
    THD< 10%

    Durable Construction

    HousingCopper Free Aluminum
    IP RatingIP66
    IK RatingIK10
    Surge Protection10kV
    Operating Temperature-22°F to 122°F
    CertificationsETL | Rebate Eligible
    Warranty5 years

    Measurements

    Dimensions (in)12.5 X 9.5 X 6.5
    Weight (lbs)26

    Product SKU Variations

    • SKU: MLLG-E-LED-EXPLA-80-50-C1D2
    • SKU: MLLG-E-LED-EXPLA-80-50-HV-C1D2

    Product Lighting Layout Estimator

    Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

    Project Inputs

    Loading fixture information...

    Estimated Results

    Fixtures --
    Layout --
    Estimated Avg FC --
    Approx. Spacing --
    Fixture Offset --
    Calculation Method: --
    Top-Down Fixture Layout Fixture positions and estimated floor light levels
    Lower estimated FC Near target Higher estimated FC

    Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

    Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

    Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

    Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

    Need Verified Light Levels?

    This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

    Estimator Version 2.9.21

    Product Overview

    This 80 watt square LED explosion proof light delivers 11,200 lumens at 5000K for hazardous location lighting. It is available in 100V-277V or 277V-480V configurations and supports 1-10V dimming.

    The fixture can replace a 250 watt metal halide light where its hazardous-location classifications, mounting configuration, and optical distribution meet project requirements.

    Core Performance and Output

    The fixture produces 140 lumens per watt with a standard 120 degree beam angle. Optional 40 degree, 60 degree, and 90 degree beam angles provide narrower distribution choices where a broad 120 degree pattern is not appropriate.

    A tempered glass lens protects the optical assembly. The 5000K color temperature and 70+ CRI configuration provide a cool white output for industrial hazardous-location areas.

    Build Quality and Physical Characteristics

    The gray copper-free aluminum housing measures 12.5 x 9.5 x 6.5 inches and weighs 26 pounds. It is rated IP66 and IK10, with 10kV surge protection.

    The operating temperature range is -22 degrees F to 122 degrees F. Rated life is 50,000 L70 hours.

    Where This Product Fits Best

    This fixture is designed for hazardous and industrial locations requiring an explosion proof lighting configuration with applicable Class I, Class II, or Class III classifications.

    • hazardous location lighting
    • explosion proof lighting
    • paint booth lighting
    • chemical processing facility lighting
    • oil and gas facility lighting
    • refinery lighting
    • marine environment lighting
    • offshore rig lighting

    Installation and Long-Term Use

    Mounting options are yoke mounting or 3/4 in NPT pendant mounting. Select the fixture voltage configuration to match the electrical system: 100V-277V or 277V-480V.

    The fixture operates at 50-60Hz, has power factor greater than 0.95, and total harmonic distortion below 10%.

    Safety, Certifications, and Warranty

    This fixture is UL 844 rated for hazardous locations: Class I, Division 2, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; and Class III. It is also UL 1598 suitable for wet locations, UL 1598A Marine Outside Type, ABS, ETL, ATEX, and IECEx rated.

    ATEX marking is II 2 G Ex eb mb IIC T5…T6 Gb and II 2 D Ex tb IIIC T80 degrees C…T100 degrees C Db. IECEx marking is Ex eb mb IIC T5…T6 Gb and Ex tb IIIC T80 degrees C…T100 degrees C Db. The fixture includes a 5 year warranty.

    Frequently Asked Questions

    Q: What mounting options are available for this explosion proof LED light?

    A: This 80 watt square explosion proof LED light is available with yoke mounting or 3/4 in NPT pendant mounting.

    Q: What beam angles are available?

    A: This explosion proof LED light has a standard 120 degree beam angle and optional 40 degree, 60 degree, or 90 degree beam angles.

    Q: What voltage configurations are available?

    A: This 80 watt explosion proof LED light is available in 100V-277V or 277V-480V configurations.

    Web ID: 1541