18 Foot Fiberglass Piling | 5 Inches Square
Out of stock
Product Specifications
Key Features
| Brand | LED Lighting Supply |
| Total Height (ft) | 18 |
| Material | Fiberglass Piling |
| Pole Weight (lbs) | 76.5 |
| Pole Width (in) | 5 |
| Pole Finish | Fluoropolymer Coating |
| Pole Color | Bronze | Black | White | Gray | Custom |
| Pole Gauge | .25 in |
| Pole Installation | Direct Burial |
| Warranty | 7 years |
Delivery is made with a flatbed truck and the customer is responsible for offloading. Offloading requires a forklift or appropriate similar machine (customer supplied). Customer is responsible for any costs associated with delivery rescheduling because of improper scheduling or not having the proper offloading equipment available at the time of delivery.
Pricing: Does not include cost of shipping. Shipping is available to the lower 48 USA states. We can supply a budgetary shipping quote or a firm shipping quote that is good for 14 days to your delivery location.
Disclaimer: LED Lighting Supply is not responsible for improper loading (ie what is mounted to the piling), installation costs, or foundation design of piling. Dimensions and specifications of pilings are subject to change without notice.
Please be advised that our fiberglass pilings are covered solely by a 7-year workmanship warranty, which ensures that the pilings are free from defects from the manufacturing process, and structural integrity, for a period of 7 years from the date of purchase. This warranty does not cover damage resulting from external factors, misuse, or normal wear and tear.
Product Overview
This 18-foot fiberglass piling has a 5-inch square profile and is designed for direct-burial structural installation. It is used where a fiberglass piling format is required for marine structures, dock structures, and pier construction.
The piling has a .25-inch wall thickness, a fluoropolymer coating, and a listed weight of 76.5 pounds. Available colors include bronze, black, white, gray, and custom colors.
Core Performance and Output
Structural performance is based on the 18-foot total length, 5-inch square profile, .25-inch wall thickness, and direct-burial installation method. EPA ratings, wind-load ratings, and fixture support limits are not provided in the supplied specifications.
The fiberglass piling format provides a non-metal structural option for the listed piling applications. Final buried depth, exposed height, loading conditions, and structural requirements must be established for the installation.
Adjustability and Control Options
This piling does not include lighting controls, electrical components, or adjustable operating settings. The available configuration options are finish color selections.
Bronze, black, white, gray, and custom colors are listed for the fluoropolymer-coated finish. The supplied specifications do not identify field-adjustable length or profile options.
Longevity and Reliability
The piling includes a 7-year warranty. Its fiberglass construction and fluoropolymer coating are part of the supplied product configuration.
Long-term condition depends on proper direct-burial installation and the loading requirements of the completed structure. The supplied specifications do not provide inspection intervals or service-life values.
Build Quality and Physical Characteristics
This is a fiberglass piling with a 5-inch square profile. Total height is 18 feet, and listed pole weight is 76.5 pounds.
The wall thickness is .25 inches. The piling has a fluoropolymer coating and is available in bronze, black, white, gray, or custom colors.
Where This Product Fits Best
This piling fits direct-burial structural work associated with marine and waterfront construction. Its 18-foot length and square fiberglass profile align with piling installations that require a defined structural member.
- dock structures
- pier construction
- marine structures
- marina construction
- boardwalk structures
- coastal facility construction
Application fit depends on the required buried depth, exposed piling height, loading conditions, and structural design. EPA, wind-load, and load-capacity values are not listed in the supplied data.
Installation and Long-Term Use
This piling is specified for direct-burial installation. Installation planning should account for the required below-grade embedment, finished exposed height, and structural layout.
The 18-foot total height is not the same as installed above-grade height because part of the piling is buried. Final placement and structural support requirements must be determined for the completed installation.
How This Fixture Is Commonly Used
For dock structures, pier construction, and marina construction, pilings are positioned as part of the structural layout rather than as isolated components. The layout follows the required structure alignment and support points.
The 18-foot total length establishes the available piling length before burial. Exposed height and spacing vary with the project structural layout, since no embedment depth or spacing values are provided.
Safety, Certifications, and Warranty
No certifications are listed in the supplied specifications. The product is identified as a fiberglass piling for direct-burial installation.
The listed warranty period is 7 years. Structural design requirements remain project-specific because load, wind, and EPA information is not supplied.
Frequently Asked Questions
Q: What is the total height of this fiberglass piling?
A: The total height is 18 feet.
Q: What is the profile size of the piling?
A: The piling has a 5-inch square profile.
Q: How is this piling installed?
A: The specified installation method is direct burial.
Q: What is the wall thickness?
A: The wall thickness is .25 inches.
Q: What warranty is provided?
A: The listed warranty is 7 years.
Application Questions and Clarification
Q: Is this piling appropriate for dock structures and pier construction?
A: Dock structures and pier construction are listed applications for this piling family. Final suitability depends on the project structural requirements.
Q: What should be confirmed before using this piling for marina construction?
A: Confirm the required buried depth, exposed height, loading conditions, and structural layout. EPA ratings and load-capacity values are not provided in the supplied specifications.
Q: Can this piling be specified for boardwalk structures?
A: Boardwalk structures are listed as a secondary application. The direct-burial installation requirement must be incorporated into the project design.
Web ID: 2770