35 Foot Piling | Class C | .60 CCA Treated | Southern Yellow Pine

SKU: LLS-PILING-35-CC-SYP-.6CCA Web ID: 2613
Starting at: $663.64
Minimum Order: 4
Minimum Order Total: $2,654.56
Built to Order 4 Weeks
This 35-foot Class C Southern Yellow Pine piling is a practical support option for marine environment lighting and architectural site lighting. Its .60 CCA treatment is specified to help prevent decay and damage, while ASTM D25 manufacturing and AWPA treatment standards support consistent material selection. The listed 985-1165 lb weight and pole dimensions help installers plan handling and mounting requirements.

Dwayne Kula | President, CTO and Founder

Product Specifications

Proudly Made or Assembled in the USA - Supporting Domestic Manufacturing1 Year Unlimited Usage Warranty

Key Features

BrandLED Lighting Supply
Total Height (ft)35
ANSI ClassClass C
MaterialWood Piling
Pole Weight (lbs)985-1165
Min Pole Top Circ (in)19
Min Pole Top OD (in)6
Min Circ 3 ft from Butt (in)38
OD 3 ft From Butt (in)12
Treatment.60 CCA
Opt Treatment.80 CCA | 1.0 CCA | 1.5 CCA | 2.5 CCA
Warranty1 year

Our 35 foot Class C CCA Treated Southern Yellow Pine Pilings are grown, debarked, and treated in the United States. They are manufactured to ASTM D25 standards and are treated to the latest American Wood Preservers Association (AWPA) standards to prevent decay and damage.

USE CASE and CCA TREATMENT LEVELS

  • Foundation: 0.6 pounds
  • Fresh Water: 0.8 pounds
  • Brackish Water, Salt Water: 1.0 pounds
  • Salt Water: 1.5 pounds
  • Salt Water where marine bores are present (piers, marinas, bulkheads, and jetties): 2.5 pounds

Delivery is made with a flatbed truck and the customer is responsible for offloading. Offloading requires a forklift or appropriate similar machine (customer supplied). Customer is responsible for any costs associated with delivery rescheduling because of improper scheduling or not having the proper offloading equipment available at the time of delivery.

Pricing: Does not include cost of shipping. Shipping is available to the lower 48 USA states. We can supply a budgetary shipping quote or a firm shipping quote that is good for 14 days to your delivery location.

Disclaimer: LED Lighting Supply is not responsible for improper loading (ie what is mounted to the piling), installation costs, or foundation design of piling. Dimensions and specifications of pilings are subject to change without notice but the tip and butt dimensions will always be within ASTM specifications. While our main product line is southern yellow pine, we at times are able to offer other species including douglas fir and red pine. All poles are treated with CCA unless specified otherwise. Our standard treatment is .60 pounds per cubic foot.

Please be advised that our wood pilings are covered solely by a 1-year workmanship warranty, which ensures that the pilings are free from defects from the manufacturing process, and structural integrity, for a period of one year from the date of purchase. This warranty does not cover damage resulting from external factors, misuse, or normal wear and tear.

Product Overview

This 35 foot Class C wood piling is a Southern Yellow Pine piling treated with .60 CCA for marine and waterfront structural work. It is grown, debarked, and treated in the United States.

The piling is manufactured to ASTM D25 standards and treated to current AWPA standards. Its 35 foot overall length supports projects where driven depth and exposed structural length must be coordinated with site conditions.

Core Performance and Output

This piling has a minimum 19 inch top circumference and a minimum 38 inch circumference measured 3 feet from the butt. The minimum top outside diameter is 6 inches, while the outside diameter 3 feet from the butt is 12 inches.

Weight ranges from 985 to 1,165 pounds. Handling equipment, driving equipment, and site access need to accommodate the piling length and weight.

The .60 CCA treatment provides decay resistance. Optional treatment levels include .80 CCA, 1.0 CCA, 1.5 CCA, and 2.5 CCA.

Adjustability and Control Options

This is a fixed-length, 35 foot wood piling. It does not include adjustable structural components or control systems.

Treatment retention can be selected from the listed .60 CCA standard treatment and optional higher CCA treatment levels. Treatment selection should align with the project requirements.

Longevity and Reliability

The .60 CCA treatment is intended to resist decay and damage. Treatment is applied in accordance with current AWPA standards.

Southern Yellow Pine is the specified wood material. The piling carries a 1 year warranty.

Build Quality and Physical Characteristics

This Class C piling is manufactured from wood and has a tapered profile from the butt to the top. The minimum circumference at 3 feet from the butt is 38 inches.

The piling has a minimum 19 inch top circumference. Natural wood dimensions and weight vary within the stated minimum dimensions and weight range.

Where This Product Fits Best

This piling fits waterfront and marine structural work requiring treated wood pilings. Its length, Class C designation, and treatment make it applicable where a driven wood support is part of the structural design.

  • marine structures
  • dock structures
  • pier construction
  • waterfront structures
  • marina construction
  • boardwalk structures

Project conditions should account for the piling’s 35 foot length, butt dimensions, treatment level, and installation equipment access. Coastal facility construction and mooring structures may require review of the specified CCA treatment level.

Installation and Long-Term Use

The piling requires handling and driving equipment appropriate for a 985 to 1,165 pound wood member. Site access must allow safe movement and positioning of the full 35 foot length.

Embedment depth, exposed height, driving method, and final cut elevation are project-specific structural requirements. The supplied product data does not establish an installation depth or load capacity.

How This Fixture Is Commonly Used

In marine structures, dock structures, and pier construction, these pilings are positioned as driven structural members according to the project layout. The 35 foot overall length is divided between embedded and exposed portions based on the structural design.

For marina construction and boardwalk structures, piling locations follow the planned support line, deck arrangement, or waterfront layout. Final spacing varies with structural loading, site conditions, and project requirements.

Safety, Certifications, and Warranty

This piling is manufactured to ASTM D25 standards. The treatment complies with current AWPA standards.

The warranty is 1 year. Installation planning must account for the stated length, weight range, and minimum piling dimensions.

Frequently Asked Questions

Q: What is the overall length of this piling?

A: The piling is 35 feet long.

Q: What are the minimum top and butt dimensions?

A: The minimum top circumference is 19 inches, with a minimum top outside diameter of 6 inches. At 3 feet from the butt, the minimum circumference is 38 inches and the outside diameter is 12 inches.

Q: What treatment does this piling have?

A: The standard treatment is .60 CCA. Optional treatment levels are .80 CCA, 1.0 CCA, 1.5 CCA, and 2.5 CCA.

Q: What should be reviewed when planning a piling layout?

A: Review the 35 foot length, the stated minimum top and butt dimensions, the 985 to 1,165 pound weight range, and project-specific structural requirements. The supplied product data does not establish piling spacing or embedment depth.

Application Questions and Clarification

Q: Is this piling applicable to dock structures and pier construction?

A: Dock structures and pier construction are listed applications for this piling. Final structural suitability depends on the project requirements.

Q: Can this piling be used for marina construction?

A: Marina construction is a listed secondary application. Confirm the required treatment level and structural design requirements for the project.

Q: What should be considered for waterfront structures?

A: Consider the required piling length, treatment level, minimum dimensions, handling weight, and project-specific embedment and loading requirements.