50 Watt LED High Temperature Light | 7500 Lumens | 5000K | 100-277V | Rated to 212F
Product Specifications
Key Features
| Brand | LED Lighting Supply |
| Watts | 50 |
| Lumens | 7500 |
| Lumens Per Watt | 150 |
| Replaces | 250 Watt Metal Halide |
| Voltage | 100V-277V |
| Color Temperature | 5000K |
| CRI | 70+ |
| Dimming | No |
| Beam Angles (Std) | 90° |
| Beam Angles (Opt) | 25° or 60° |
| Optics | Polycarbonate Lens |
| Lifespan | 100,000 (L70) hours |
| Mounting | Eye-Hook or Pendant or Trunnion |
| Fixture Color | Gray |
| Frequency (Hz) | 50/60 |
| Power Factor | > .95 |
| THD | < 15% |
Durable Construction
| Housing | Aluminum Alloy |
| IP Rating | IP66 |
| Surge Protection | 6kV |
| Operating Temperature | -40°F to 212°F |
| Certifications | ETL |
| Warranty | 5 years |
Measurements
| Dimensions (in) | 12 x 10.5 x 2.5 |
| Weight (lbs) | 11 |
Product Lighting Layout Estimator
Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.
Project Inputs
Estimated Results
Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.
Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.
Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.
Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.
This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.
Product Overview
This 50 watt LED high temperature light delivers 7,500 lumens at 5000K for facilities with elevated ambient temperatures. It operates on 100-277V power and is rated for operation from -40F to 212F.
The compact fixture uses an aluminum alloy housing, polycarbonate lens, and a standard 90-degree beam angle. Eye-hook, pendant, and trunnion mounting options support different fixture orientations and mounting layouts.
Core Performance and Output
The fixture produces 150 lumens per watt and is identified as a replacement for 250 watt metal halide lighting. Its 70+ CRI and 5000K color temperature provide a cool white industrial lighting appearance.
A 90-degree beam angle is standard. Optional 25-degree and 60-degree beam angles provide narrower distribution options where the standard optic is not appropriate.
Longevity and Reliability
This LED high temperature light has a rated life of 100,000 L70 hours. It includes 6kV surge protection, a power factor greater than 0.95, and total harmonic distortion below 15%.
The IP66-rated housing is designed for demanding industrial environments, while the aluminum alloy construction supports heat management at operating temperatures up to 212F.
Build Quality and Physical Characteristics
The gray fixture measures 12 x 10.5 x 2.5 inches and weighs 11 pounds. Its polycarbonate lens protects the optical assembly, and the fixture operates at 50/60 Hz.
Where This Product Fits Best
This fixture is intended for high-temperature industrial locations where conventional high bay fixtures may not be suitable for the ambient operating temperature.
- high temperature facility lighting
- industrial furnace area lighting
- steel mill lighting
- foundry lighting
- power plant and energy site lighting
- nuclear facility lighting
- kiln lighting
- boiler room lighting
Safety, Certifications, and Warranty
This fixture is ETL certified and carries a 5-year warranty.
Frequently Asked Questions
Q: Can this high temperature light be dimmed?
A: No. This 50 watt LED high temperature light is not dimmable.
Q: What mounting options are available for this fixture?
A: This LED high temperature light supports eye-hook, pendant, or trunnion mounting.
Q: What beam angle comes standard with this light?
A: This LED high temperature light has a standard 90-degree beam angle, with 25-degree and 60-degree beam angles available as options.
Web ID: 2595