Skip to content

15+ Years of Lighting Commercial, Industrial, and Sports Projects

50 Watt Round Explosion Proof LED Light | 7000 Lumens | Class 1 Div 1 | 5000K | 100-277V

SKU: LLS-EXPLC-50-5-C1D1 Web ID: 2313
Starting at: $658.00
Availability: 45 In Stock Ships 3-5 Days
This 50W explosion-proof fixture suits hazardous industrial and marine outdoor installations requiring Class I, II, or III ratings. It delivers 7,000 lumens at 140 lm/W, replacing 250W metal halide while supporting 100-277V power and 1-10V dimming. IP66, IK10, 6kV surge protection, and a -22F to 122F operating range support demanding wet and exposed environments. Yoke or 3/4 in NPT pendant mounting aids installation flexibility.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

45 in stock (can be backordered)

Product Options

Product total

Options total

Sub-Total

Product Specifications

UL Listed - Verified for Electrical Safety and PerformanceCSA Listed - Verified for Electrical Safety and PerformanceClass 1 Division 1 - UL844 Certified for Hazardous Locations5 Year Unlimited Usage Warranty

UL Specs

  • UL 844 Hazardous Locations
  • Class 1 Division 1, Group B,C,D
  • Class 1 Division 2, Group B,C,D
  • Class 2, Division 1, Groups E,F,G
  • Class 2, Division 2, Groups F,G
  • Class 3
  • UL 1598 Suitable for Wet Locations
  • UL 1598A Marine Outside Type
  • CSA / ATEX / IECEX

Key Features

BrandLED Lighting Supply
Watts50
Lumens7000
Lumens Per Watt140
Replaces250 Watt Metal Halide
Voltage100V-277V
Color Temperature5000K
CRI70+
Dimming1-10V
Beam Angles (Std)120°
OpticsTempered Glass Lens
Lifespan150,000 (L70) hours
MountingYoke or 3/4 in NPT Pendant
Mounting (Opt)Surface or Wall
Fixture ColorGray
Frequency (Hz)50/60
Power Factor>.90
THD< 10%

Durable Construction

HousingPowder Coated Aluminum
IP RatingIP66
IK RatingIK10
Surge Protection6kV
Operating Temperature-22°F to 122°F
CertificationsUL
Warranty5 years

Measurements

Dimensions (in)13.7 X 11.2
Weight (lbs)20
Cord LengthNo Cord

Notes

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.21

Product Overview

This 50 watt round LED explosion proof light delivers 7,000 lumens at 5000K through a tempered glass lens. It operates on 100-277V power and supports 1-10V dimming for compatible control systems.

The fixture is rated for Class I, Division 1 and 2, Groups B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; and Class III locations.

Core Performance and Output

The 120 degree beam angle provides broad light distribution from a 50 watt fixture producing 140 lumens per watt. This model is identified as a replacement for 250 watt metal halide lighting.

It operates at 50/60 Hz with power factor greater than 0.90 and total harmonic distortion below 10%.

Adjustability and Control Options

1-10V dimming is available for installations using compatible low-voltage dimming controls. Standard mounting choices are a yoke or 3/4 inch NPT pendant mount. Surface and wall mounting are optional configurations.

Longevity and Reliability

The LED system is rated for 150,000 hours L70 life and is covered by a 5 year warranty. The fixture operates from -22 degrees F to 122 degrees F and includes 6kV surge protection.

Build Quality and Physical Characteristics

The gray powder-coated aluminum housing is IP66 rated and IK10 rated. The round fixture measures 13.7 x 11.2 inches and weighs 20 pounds. It is supplied without a cord.

Where This Product Fits Best

This explosion proof fixture is suited to listed hazardous-location lighting applications where its classification, sealed construction, and available mounting arrangements align with project requirements.

  • hazardous location lighting
  • explosion proof lighting
  • paint booth lighting
  • chemical processing facility lighting
  • oil and gas facility lighting
  • refinery lighting
  • marine environment lighting
  • wastewater treatment lighting

Safety, Certifications, and Warranty

The fixture carries UL 844 Hazardous Locations, UL 1598 Suitable for Wet Locations, and UL 1598A Marine Outside Type classifications. It also carries CSA, ATEX, and IECEx certifications. Warranty coverage is 5 years.

Frequently Asked Questions

Q: What mounting options are available for this 50 watt explosion proof light?

A: This 50 watt explosion proof light has yoke and 3/4 inch NPT pendant mounting options, with surface and wall mounting available as optional configurations.

Q: Can this explosion proof light be dimmed?

A: Yes. This explosion proof light supports 1-10V dimming with compatible low-voltage dimming controls.

Q: What hazardous location classifications does this fixture carry?

A: This fixture is rated for Class I, Division 1 and 2, Groups B, C, and D; Class II, Division 1, Groups E, F, and G; Class II, Division 2, Groups F and G; and Class III locations.