Skip to content

Explosion Proof Wall Mount Arm Bracket | Class 1 Div 2

SKU: MLLG-E-EXPL-Wall-ARM Web ID: 1995
Starting at: $106.73
Availability: 234 In Stock Ships 3-5 Days
This wall mount arm bracket is a practical choice for installing compatible EXPLA and EXPLB explosion proof fixtures in classified areas. Its UL844 hazardous-location listing, including Class 1 Div 2 Groups E, F, G and Class 2 Div 1 Groups A, B, C, D, supports use in hazardous location and paint booth lighting applications. The compact 5.6 x 5.6 x 4.2 inch size helps where mounting space is limited.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online? Select Options

234 in stock

Product total

Options total

Sub-Total

Product Specifications

UL Specs

  • UL844 Hazardous Location
  • Class 1 Div 2: Groups E,F,G
  • Class 2 Div 1: Groups A,B,C,D

Key Features

BrandLED Lighting Supply

Measurements

Dimensions (in)5.6 x 5.6 x 4.2

Explosion Proof Wall Mount Arm Bracket. Designed for our

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.21

Product Overview

This explosion proof wall mount arm bracket supports wall-mounted EXPLA and EXPLB explosion proof fixtures. It is intended for hazardous location lighting installations where the fixture requires a wall arm mounting arrangement.

The bracket measures 5.6 x 5.6 x 4.2 inches. Its hazardous-location classifications align with installations requiring Class I Division 2 or Class II Division 1 equipment.

Core Performance and Output

This is a fixture mounting component and does not produce light output. Its function is to provide a wall mount arm configuration for compatible EXPLA and EXPLB fixtures.

Bracket placement must account for the fixture dimensions, wall structure, aiming requirements, and available clearance. The supplied data does not establish fixture weight capacity, EPA rating, or wind-load performance.

Adjustability and Control Options

No fixture controls, dimming functions, or electrical components are included with this wall mount arm bracket. Controls are determined by the compatible EXPLA or EXPLB fixture configuration.

The supplied product data does not identify an adjustable arm, swivel, or aiming mechanism. Final fixture direction depends on the installed fixture and wall mounting position.

Longevity and Reliability

The bracket is classified for UL 844 hazardous location use. It is intended for installations using compatible EXPLA and EXPLB fixtures.

Long-term performance depends on correct wall mounting, fixture compatibility, and maintaining the installation within the listed hazardous-location classification. Material construction and environmental exposure limits are not stated in the supplied data.

Build Quality and Physical Characteristics

The bracket has overall dimensions of 5.6 x 5.6 x 4.2 inches. Its compact size should be checked against available wall surface, conduit routing, fixture clearance, and required aiming position.

This bracket is designed for EXPLA and EXPLB explosion proof fixtures. No alternate fixture compatibility is identified in the supplied product information.

Where This Product Fits Best

This wall mount arm bracket fits hazardous-location lighting installations using compatible EXPLA or EXPLB fixtures. It applies where a wall-mounted fixture position is required within the listed classifications.

  • hazardous location lighting
  • explosion proof lighting
  • paint booth lighting
  • chemical processing facility lighting
  • oil and gas facility lighting
  • refinery lighting

Installation conditions must remain consistent with the listed Class I Division 2 Groups E, F, and G and Class II Division 1 Groups A, B, C, and D classifications. The supplied data does not establish suitability for applications outside these classifications.

Installation and Long-Term Use

The bracket mounts compatible EXPLA and EXPLB fixtures to a wall-mounted arm position. Confirm wall structure, mounting location, fixture clearance, and the required fixture orientation before installation.

Mounting height is determined by the lighting layout and fixture placement requirements for the project. The supplied data does not provide a mounting-height range, hardware list, or structural loading value.

How This Fixture Is Commonly Used

This bracket is used where hazardous location lighting requires an EXPLA or EXPLB fixture to be positioned from a wall. Wall placement is coordinated with the intended fixture direction and the available mounting surface.

Fixture layout depends on mounting height, target light levels, and the arrangement of the hazardous location lighting area. A wall-mounted position can affect fixture spacing and aiming compared with other mounting configurations.

Safety, Certifications, and Warranty

UL 844 hazardous location.

Class I Division 2, Groups E, F, G. Class II Division 1, Groups A, B, C, D.

Warranty information is not included in the supplied product data.

Frequently Asked Questions

Q: What fixtures are compatible with this wall mount arm bracket?

A: This bracket is designed for EXPLA and EXPLB explosion proof fixtures.

Q: What are the dimensions of the bracket?

A: The bracket measures 5.6 x 5.6 x 4.2 inches.

Q: What hazardous-location classifications are listed for this bracket?

A: It is listed as UL 844 hazardous location, Class I Division 2 Groups E, F, and G, and Class II Division 1 Groups A, B, C, and D.

Q: What should be reviewed when planning bracket placement?

A: Confirm EXPLA or EXPLB fixture compatibility, wall mounting location, bracket dimensions, fixture clearance, mounting height, and required fixture direction. The supplied data does not provide fixture spacing or mounting-height values.

Application Questions and Clarification

Q: Can this bracket be used for hazardous location lighting?

A: Yes. The bracket is listed for UL 844 hazardous location use with Class I Division 2 Groups E, F, and G and Class II Division 1 Groups A, B, C, and D classifications.

Q: Can this bracket be used for paint booth lighting?

A: Paint booth lighting is a valid application when the installation uses compatible EXPLA or EXPLB fixtures and meets the listed hazardous-location classification requirements.

Q: What needs confirmation for chemical processing facility lighting?

A: Confirm that the installation classification matches the bracket listing and that the fixture is an EXPLA or EXPLB model. Wall structure, fixture position, mounting height, and final layout remain project-specific.

Web ID: 1995