Skip to content

15+ Years of Lighting Commercial, Industrial, and Sports Projects

Explosion Proof Arm Bracket With Junction Box | 25 Degree Mount | Class 1 Div 1

SKU: MLLG-E-EXPL-WALL-25-JB Web ID: 1991
Starting at: $255.00
Availability: 276 In Stock Ships 3-5 Days

Lighting a large indoor space?

Get a free lighting plan and volume pricing to ensure uniform illumination without overbuying fixtures.

Get Contractor or Bulk Pricing

Get your quote within 1 hour!

Call to Order: (888) 423-3191
This 25 degree arm bracket with junction box is a practical mounting choice for compatible EXPLA, EXPLB, EXPLC, EXPLD, and EXPLG explosion-proof fixtures. Its UL844 hazardous-location classifications support use in specified Class 1 and Class 2 divisions and groups, while the IP67 rating suits demanding paint booth and hazardous-location installations. Compact 5.6 x 5.6 x 4.2 inch dimensions and a five-year warranty add installation and ownership confidence.

Dwayne Kula | President, CTO and Founder

Prefer to Order Online?

276 in stock

Product total

Options total

Sub-Total

Product Specifications

CSA Listed - Verified for Electrical Safety and PerformanceClass 1 Division 1 - UL844 Certified for Hazardous LocationsClass 1 Division 2 - UL844 Certified for Explosive Atmospheres5 Year Unlimited Usage Warranty

UL Specs

  • UL844 Hazardous Location
  • Class 1 Div 1: Groups A, B, C, D
  • Class 1 Div 2: Groups A, B, C, D
  • Class 2 Div 1: Groups E,F,G
  • Class 2 Div 2: Groups F,G

Key Features

BrandLED Lighting Supply

Durable Construction

IP RatingIP67
Warranty5 years

Measurements

Dimensions (in)5.6 x 5.6 x 4.2

Designed for:

Product Lighting Layout Estimator

Use this estimator to calculate approximate fixture count, spacing, and average foot-candles for a simple rectangular space using the selected LED fixture. Enter your room dimensions, mounting height, target foot-candles, light loss factor, and room/layout condition to generate a preliminary lighting layout. When IES photometry is available, workplane height and room reflectance controls are shown.

Project Inputs

Loading fixture information...

Estimated Results

Fixtures --
Layout --
Estimated Avg FC --
Approx. Spacing --
Fixture Offset --
Calculation Method: --
Top-Down Fixture Layout Fixture positions and estimated floor light levels
Lower estimated FC Near target Higher estimated FC

Estimated average foot-candles are preliminary and should be verified with a lighting plan for project-critical applications.

Room / Layout Condition: This field is used only when usable IES photometry is not available. In fallback mode, it acts as a simplified room utilization factor for reflectance, fixture distribution, racking, obstructions, and how much fixture light reaches the work area. Open / light-colored spaces use 0.90, typical warehouses or shops use 0.75, racked or obstructed spaces use 0.60, and dark or complex spaces use 0.45. When IES photometry is active, this field is hidden and the estimator uses the selected workplane height, LLF, and simplified reflectance adjustment instead.

Photometry / Simulation Note: When usable IES photometry is available for the selected fixture, this estimator uses the fixture’s IES candela data, selected workplane height, light loss factor, and simplified reflectance adjustment to estimate fixture count, average foot-candles, and visual light distribution. The reflectance adjustment is a conservative approximation and is not a full zonal-cavity, radiosity, or professional photometric room calculation. When IES photometry is not available, the estimator uses a simulated beam model based on lumens, mounting height, room/layout condition, light loss factor, and beam angle.

Preliminary Estimate Only: This estimator is intended for simple square or rectangular spaces and should be used as a planning aid, not a final photometric lighting plan. Actual light levels may vary based on fixture optics, selected IES file, mounting conditions, workplane height, ceiling height, surface reflectance, obstructions, controls, voltage, installation conditions, and site-specific requirements. Project-critical applications should be verified with a formal lighting plan.

Need Verified Light Levels?

This estimate is a starting point. Warehouses, industrial facilities, hazardous locations, sports areas, schools, healthcare spaces, public areas, and code-sensitive projects may require a reviewed lighting layout before purchase or installation.

Estimator Version 2.9.21

Product Overview

This explosion proof arm bracket with junction box provides a 25-degree mounting configuration for compatible EXPLA, EXPLB, EXPLC, EXPLD, and EXPLG explosion proof fixtures. Its compact 5.6 x 5.6 x 4.2 inch enclosure combines fixture support and a junction box connection point.

Build Quality and Physical Characteristics

The bracket and junction box assembly is IP67 rated and measures 5.6 x 5.6 x 4.2 inches. The 25-degree arm angle supports an angled fixture orientation where this mounting configuration is required.

Where This Product Fits Best

This accessory is intended for compatible explosion proof fixture installations in classified hazardous locations and paint booth lighting projects.

  • hazardous location lighting
  • explosion proof lighting
  • paint booth lighting
  • chemical processing facility lighting
  • oil and gas facility lighting
  • refinery lighting
  • solvent storage area lighting

Safety, Certifications, and Warranty

This arm bracket with junction box is UL844 hazardous location rated for Class I, Division 1 Groups A, B, C, and D; Class I, Division 2 Groups A, B, C, and D; Class II, Division 1 Groups E, F, and G; and Class II, Division 2 Groups F and G. It carries a 5-year warranty.

Frequently Asked Questions

Q: Which explosion proof fixtures work with this arm bracket?

A: This 25-degree arm bracket with junction box is designed for EXPLA, EXPLB, EXPLC, EXPLD, and EXPLG explosion proof fixtures.

Q: What hazardous location classifications apply to this bracket?

A: This bracket is UL844 hazardous location rated for Class I, Division 1 and 2 Groups A, B, C, and D; Class II, Division 1 Groups E, F, and G; and Class II, Division 2 Groups F and G.

Q: What are the dimensions of the arm bracket with junction box?

A: The explosion proof arm bracket with junction box measures 5.6 x 5.6 x 4.2 inches.

Web ID: 1991